59
AcraDyne Gen IV iAC Controller Manual
Supported MID
MID Description
Revisions Note
70
Alarm subscribe
71
Alarm
72
Alarm acknowledge
73
Alarm unsubscribe
76
Alarm status
77
Alarm status acknowledge
80
Read time upload request
81
Read time upload reply
82
Set time
113 Flash green light on tool
127 Abort Job
130 Job off
150
Identifier download request
157
Reset all Identifiers
200 Set external controlled relays
Only supports
0 (off) and
1 (on)
210 Status external monitored inputs
subscribe
211 Status external monitored inputs
212 Status external monitored inputs
acknowledge
213 Status external monitored inputs
unsubscribe
214 IO device status request
1,2
215 IO device status reply
216 Relay function subscribe
See
supported
relay
functions
below.
217 Relay function
218 Relay function acknowledge
219 Relay function unsubscribe
9999 Keep alive open protocol
communication
Supported MID
MID Description
Revisions Note
1
Communication start
1,2,3
2
Communication start
acknowledge
1,2,3
3
Communication stop
4
Command error
5
Command accepted
10
Parameter set ID upload request
11
Parameter set ID upload reply
14
Parameter set selected subscribe
15
Parameter set selected
16
Parameter set selected
acknowledge
17
Parameter set selected
unsubscribe
18
Select Parameter set
19
Set Parameter set batch size
20
Reset Parameter set batch
counter
30
Job ID upload request
31
Job ID upload reply
34
Job info subscribe
35
Job info
36
Job info acknowledge
37
Job info unsubscribe
38
Select Job
39
Job restart
40
Tool data upload request
1,2
41
Tool data upload reply
42
Disable tool
43
Enable tool
50
Vehicle ID number download
request
51
Vehicle ID number subscribe
1,2
52
Vehicle ID number
53
Vehicle ID number acknowledge
54
Vehicle ID number unsubscribe
60
Last tightening result data
subscribe
1,2,3,999
61
Last tightening result data
62
Last tightening result data
acknowledge
63
Last tightening result data
unsubscribe
64
Old tightening result upload
request
65
Old tightening result upload reply
11.1 Controller Supported MIDs
Supported Relay Functions
Number
Function
1
OK
2
NOK
5
Low Torque
6
High Torque
7
Low angle
8
High angle
9
Cycle complete
10
Alarm
Supported Relay Functions
Number
Function
11
Batch NOK
12
Job OK
19
Tool ready
20
Tool start switch
21
Dir. switch = CW
22
Dir. switch = CCW
26
Tool running
276
Cycle abort
Supported Relay Functions