12
AcraDyne Gen IV iAC Controller Manual
4.2 PSet
Parameter Settings (PSets) control the fastening
process. The following describes the different
fastening strategies and how to setup the basic PSet
parameters necessary to perform a fastening. Up to
256 PSets are available.
4.2.1 Add New PSet
On Home Page press the
tab.
On PSets screen press to add a new Pset.
Add a PSet
Edit a PSet
Coy a PSet
Delete a PSet
Default PSets
(see "3.4 Quick Set Up" on page 9)
Manage PSets
(see "4.2.5 Manage PSets" on page 17)
On Add New PSet screen (below) enter appropriate
values.
PSet Number:
Current
PSet to be added.
Torque Units:
Unit of
measure.
In Cycle Torque:
Threshold value at
which tool is “In
Cycle” and results
from the Rundown
will be reported. This
value is also used
to count pulses by
determining the start
of a pulse.
Time Limit (s):
Maximum allowable time (in seconds)
tool is allowed to run after going ‘In Cycle’.
Advanced Options:
on page 16)
Once PSet values are entered press
to enter
Add
New Stage
screen.
4.2.1.1 Add New Stage
A single stage or multiple stages build a PSet. Up to
20 stages can be assigned per PSet.
The following stage options are available (for stage
descriptions, see "4.2.2 PSet Stages" on page 13):
Once the desired stage(s) are selected and
configured, press
to save stage and again to
save the
PSet
and return to initial PSet menu.
Next Press
to go to the
RUN
screen or
to
return to the
Home
page. The tool should now be
operational and you are ready to run a configured
PSet.