43
AcraDyne Gen IV iAC Controller Manual
Code
Icon
Description
BRCD
Bar Code ID scan required to
enable tool
SRVC
Tool Disabled For Service - Tool
service or calibration interval has
expired
INVP
Invalid PSet - Parameter set
number for a non-existent Pset
has been selected to run. Most
likely via one of the following
methods:
○
Job
○
MFB
○
I/O
INVP
PSet outside of Job - Parameter
set number outside of the
job has been selected. Most
likely via one of the following
methods:
○
MFB
○
I/O
INVJ
Invalid Job - Job number for
a non-existent Job has been
selected to run. Most likely via
one of the following methods:
○
MFB
○
I/O
PSET
PSet Mismatch
SPND
Spindle Not Configured –
Spindle selected to run from a
Multi-Spindle Job has not been
configured
NET
XML Disconnected
XML
Stop from XML
NOK
XML Max Rejects Exceeded
FLT
Controller Fault - Error has been
detected. See fault code list for
details
Code
Icon
Description
IO
Stopped or Disabled from
Physical 24 volt IO input
ABUS
Stopped or Disabled from
ANYBUS
MODB
Stopped or Disabled from
Modbus
EIP
Stopped or Disabled from
Ethernet IP
RTU
Stopped or Disabled from
Modbus RTU
OP
Stopped or Disabled from Open
Protocol
OP
Lost Open Protocol Connection
REV
Disassembly Disabled
ARM
Tool Requires Arming – MFB
button configured to enable the
tool to run.
JOB
Job Sequence Complete
JOB
Job Complete
JOB
XML Count Complete
LOR
Locked on Reject
If a Stop condition is detected that prevents the tool from running, a code will appear on the LED display. Any
active stop conditions are also displayed on the RUN screen.
8. Stop Codes