50
AcraDyne Gen IV iAC Controller Manual
ASCII ID
Supported Feature
Bus Element Bit 0-31 Polarity N.O./N.C. Width Offset
√
√
Abort Job
Supported Feature
Bus Element Bit 0-31 Polarity N.O./N.C. Width Offset
√
√
√
√
The “Abort Job” assignment , aborts the job and
disables the tool. A job reset is required to enable
the tool for the next job.
Remote Start
Supported Feature
Bus Element Bit 0-31 Polarity N.O./N.C. Width Offset
√
√
√
√
The “Remote Start” assignment will run the tool while
the input is active. Remote Start is available for non-
physical I/O buses.
Remove Lock on Reject
Supported Feature
Bus Element Bit 0-31 Polarity N.O./N.C. Width Offset
√
√
√
√
The “Remove Lock on Reject” assignment unlocks
the tool if locked on reject, re-enabling the tool.
Log Change
Supported Feature
Bus Element Bit 0-31 Polarity N.O./N.C. Width Offset
√
√
√
√
The “Log Change” assignment will add entries to the
controller event log when the input changes.
Decrement Batch
Supported Feature
Bus Element Bit 0-31 Polarity N.O./N.C. Width Offset
√
√
√
√
The “Decrement Batch” assignment will remove the
latest OK rundown from the current running JOB. This
will cause the JOB count to be reduced by one.
Increment Batch
Supported Feature
Bus Element Bit 0-31 Polarity N.O./N.C. Width Offset
√
√
√
√
The “Increment Batch” assignment will insert a
manual rundown into the current sequence of
the current JOB. This will cause the JOB count to
increment by one.
Click Wrench
Supported Feature
Bus Element Bit 0-31 Polarity N.O./N.C. Width Offset
√
√
√
√
The “Click Wrench” assignment is the same
as “Increment Batch" with the addition of a
programmable torque value.
Bypass Stops
Supported Feature
Bus Element Bit 0-31 Polarity N.O./N.C. Width Offset
√
√
√
√
The “Bypass Stops” assignment removes most stop
conditions, allowing the tool to be ran in an override
type condition. Hardware faults, stop and disable
inputs are not removed.
Verify Job Sequence
Supported Feature
Bus Element Bit 0-31 Polarity N.O./N.C. Width Offset
√
√
√
√
√
The “Verify Job Sequence” input will compare the
current Job sequence to the input value. Uses the
width parameter limit the width of the input bits
read. The minimum width is 1 and the maximum
is 8. After the input is read the offset parameter
will be added to the value do get the actual Job
sequence number. If the Job sequence input value
does not match the current Job sequence of the
controller the tool will be disabled.