28
AcraDyne Gen IV iAC Controller Manual
○
O: Overall Pass/Fail
▪
‘P’ = Pass, ‘F’ = Fail
○
P: Torque Pass/Fail
▪
‘P’ = Pass, ‘F’ = Fail
○
HHHHH: Torque High Limit
▪
Units selected in the PSet X10
○
LLLLL: Torque Low Limit
▪
Units selected in the PSet X10
○
TTTTT: Torque Result
▪
Units selected in the PSet X10
○
P: Angle Pass/Fail
▪
‘P’ = Pass, ‘F’ = Fail
○
HHHHH: Angle High Limit
▪
Degrees
○
LLLLL: Angle Low Limit
▪
Degrees
○
AAAAA: Angle Result
▪
Degrees
○
NAC%: Message End
○
CR: Carriage return control character
○
LF: Line feed control character
○
NULL*: Null control character (*if option is selected)
UEC Serial Format (matches UEC 4800 and Gen3):
• # 1 P BB TTT.T AAAA PPPP 0000 J CR NULL*
○
#: Message Start
○
1: Spindle Number (Always 1)
○
P: PSet
▪
PSet(‘1’ – ‘9’) for PSets 1-9, (‘A’ – ‘Z’) for PSets 10-35
○
BB: Job Bolt Count
▪
Total number of accepts during the Job
○
TTT.T: Torque Result
▪
Units selected in the PSet
○
AAAA: Angle Result
▪
Degrees
○
PPPP: Pulse Count
○
0000
○
J: Judgment
▪
‘@’ = Overall Pass, ‘H’ = Low Torque, ‘I’ = High
Torque, ‘J’ = Low Angle, ‘K = High Angle, ‘G’ =
Fault During Fastening
○
CR: Carriage return control character
○
NULL*: Null control character (*if option is selected)
‘CSV String’
S01,JB01, TTT.T, S, AAA.A, S, O, MM/DD/YYYY HH:MM:SS,
VVV<CR><LF>
S01: Spindle number
JB01: Job number
TTT.T: Torque
S: Torque Status (A = OK, H = High, L = Low)
AAA.A: Angle
S: Angle Status (A = OK, H = High, L = Low)
O: Overall Status (A = OK, R = NOK)
MM: Month
DD: Day
YYYY: Year
HH: Hour
MM: Minute
SS: Second
VVV: 32 character barcode ID
<CR>: Carriage Return
<LF>: Line Feed
‘Output Followed by NULL Character’.
The NULL characters can be seen by using PUTTY and
connecting to the controller in ‘Raw’ mode. Then set logging to
log all output and check the log to see the NULL characters.
‘Send PSet Change’.
PSets up to 9 match the number, 10-35 are A-Z, greater than 35
is ‘*’:
%%CAN8X%%%%CAN4YNAC%%
X: Last PSet
Y: New PSet
Standard Output Format:
• O P HHHHH LLLLL TTTTT P HHHHH LLLLL AAAAA CR CR NULL*
○
O: Overall Pass/Fail
▪
‘P’ = Pass, ‘F’ = Fail
○
P: Torque Pass/Fail
▪
‘P’ = Pass, ‘F’ = Fail
○
HHHHH: Torque High Limit
▪
Units selected in the PSet X10
○
LLLLL: Torque Low Limit
▪
Units selected in the PSet X10
○
TTTTT: Torque Result
▪
Units selected in the PSet X10
○
P: Angle Pass/Fail
▪
‘P’ = Pass, ‘F’ = Fail
○
HHHHH: Angle High Limit
▪
Degrees
○
LLLLL: Angle Low Limit
▪
Degrees
○
AAAAA: Angle Result
▪
Degrees
○
CR: Carriage return control character
○
CR: Carriage return control character
○
NULL*: Null control character (*if option is selected)
Standard Output with Carriage Return, Line Feed and PSet Format:
• O P HHHHH LLLLL TTTTT P HHHHH LLLLL AAAAA 1 CR LF NULL*
○
O: Overall Pass/Fail
▪
‘P’ = Pass, ‘F’ = Fail
○
P: Torque Pass/Fail
▪
‘P’ = Pass, ‘F’ = Fail
○
HHHHH: Torque High Limit
▪
Units selected in the PSet X10
○
LLLLL: Torque Low Limit
▪
Units selected in the PSet X10
○
TTTTT: Torque Result
▪
Units selected in the PSet X10
○
P: Angle Pass/Fail
▪
‘P’ = Pass, ‘F’ = Fail
○
HHHHH: Angle High Limit
▪
Degrees
○
LLLLL: Angle Low Limit
▪
Degrees
○
AAAAA: Angle Result
▪
Degrees
○
1: PSet
▪
PSet(‘1’ – ‘9’) for PSets 1-9, (‘A’ – ‘Z’) for PSets 10-35
○
CR: Carriage return control character
○
LF: Line feed control character
○
NULL*: Null control character (*if option is selected)
UEC Serial Modified Format (matches some Gen4 earlier versions):
• # P 1 BB TTT.T AAAA PPPP 0000 J CR NULL*
○
#: Message Start
○
P: PSet
▪
PSet(‘1’ – ‘9’) for PSets 1-9, (‘A’ – ‘Z’) for PSets 10-35
○
1: Spindle Number (Always 1)
○
BB: Job Bolt Count
▪
Total number of accepts during the Job
○
TTT.T: Torque Result
▪
Units selected in the PSet
○
AAAA: Angle Result
▪
Degrees
○
PPPP: Pulse Count
○
0000
○
J: Judgment
▪
‘@’ = Overall Pass, ‘H’ = Low Torque, ‘I’ = High
Torque, ‘J’ = Low Angle, ‘K = High Angle, ‘G’ =
Fault During Fastening
○
CR: Carriage return control character
○
NULL*: Null control character (*if option is selected)
Profibus Output Format:
• %CAN 1 O P HHHHH LLLLL TTTTT P HHHHH LLLLL AAAAA NAC%
CR LF NULL*
○
%CAN: Message Start
○
1: PSet
▪
PSet(‘1’ – ‘9’) for PSets 1-9, (‘A’ – ‘Z’) for PSets 10-35
Serial Output Format Options