57
AcraDyne Gen IV iAC Controller Manual
Torque (x100)
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Torque (x100)” output assignment will output the final torque value of the most recent rundown. The value
will be cleared to 0 at the start of a new fastening cycle or a Job reset. At the end of the fastening cycle the
final torque will be multiplied by 100, truncated to an integer and output.
Angle
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Angle” output assignment will output the final angle value of the most recent rundown. The value will be
cleared to 0 at the start of a new fastening cycle or a Job reset.
Rundown Saved to FTP Server
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Rundown Saved to FTP Server” output assignment will output the ID of the last rundown that was saved to
the FTP server.
Fastener Removed
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Fastener Removed” output assignment will go active when a fastener is removed by the operator. The
controller must be configured to report disassembly for this output to work. It will go inactive when the next
fastening is started (the torque exceeds the threshold value) or a Job reset.
Spindle Ok
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Spindle Ok” output assignment will go active at the completion of multi-spindle fastening if all spindles have an
OK. It will go inactive when the next fastening is started (the torque exceeds the threshold value) or a Job reset.
Spindle NOk
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Spindle NOk” output assignment will go active at the completion of multi-spindle fastening if one or more
of the spindles have an NOK. It will go inactive when the next fastening is started (the torque exceeds the
threshold value) or a Job reset.
Spindle Fastening Complete
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Spindle Fastening Complete” output assignment will go active at the completion of multi-spindle fastening. It
will go inactive when the next fastening is started (the torque exceeds the threshold value) or a Job reset.
Pulses
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
The “Pulses” output assignment will output the pulse count value of the most recent rundown. The value will be