4.2.2.2 TC_APM Torque Control Angle Pulse Monitor
Torque High:
Upper control limit of the rundown.
Torque Target:
Final desired torque (CUT Level).
Torque Low:
The lower control limit of the rundown.
Angle Bailout:
Determines when to stop the tool on angle during any
Torque Control strategy. Should be set equal to or above High Angle. Units
are degrees of rotation.
Angle High:
Maximum acceptable angle rotation in degrees.
Angle Low:
Minimum acceptable angle rotation in degrees.
Angle Reference
(drop down menu)
:
• In-cycle Angle:
Monitoring degrees of Angle after the tool has
overcome pre-set In Cycle Torque
• Stage Angle:
Monitor Angle specifically in the Stage
Angle Reference Torque:
Monitor degrees of Angle from the Reference
Torque value set
Pulse Bailout: :
Total number of Pulses never to be exceeded. Helps
to illustrate how far past Pulse High the rundown experienced awithout
damaging the part or excessively wearing the tool’s Pulse Fluid
Pulse High:
Maximum acceptable pulses
Pulse Low:
Minimum acceptable pulses
Pulse Reference
(drop down menu)
:
• In-cycle Pulse:
Monitoring number of tool Pulse begins after the tool
overcomes pre-set In Cycle Torque
• Stage Pulse:
Monitoring all Pulses specifically in the Stage
Additional Pulses:
After reaching target torque, additional pulses to be
applied before shutting of the air to the tool.
Pressure (PSI):
Desired amount of air pressure supplied to the tool (only
available for SR models). Note: The pressure set in the first stage of the PSet,
is applied when the tool is enabled to run.
Stage Timeout (s):
Maximum allowable time(in seconds) in this stage. If
time is exceeded, the tool will stop and the Rundown will be terminated.