53
AcraDyne Gen IV iAC Controller Manual
Output Assignments
Ok
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Ok” output assignment will go active at the completion of an acceptable fastening. It will go inactive
when the next fastening is started (the torque exceeds the threshold value) or a Job reset.
Nok
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Nok” output assignment will go active at the completion of an unacceptable fastening. It will go inactive
when the next fastening is started (the torque exceeds the threshold value) or a Job reset.
Torque Ok
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Torque Ok” output assignment will go active at the completion of a fastening that has an acceptable torque
value. It will go inactive when the next fastening is started (the torque exceeds the threshold value) or a Job reset.
Torque Nok
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Torque Nok” output assignment will go active at the completion of a fastening that has an unacceptable
torque value. It will go inactive when the next fastening is started (the torque exceeds the threshold value) or a
Job reset.
Low Torque
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Low Torque” output assignment will go active at the completion of a fastening that has a low torque results.
It will go inactive when the next fastening is started (the torque exceeds the threshold value) or a Job reset.
High Torque
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “High Torque” output assignment will go active at the completion of a fastening that has a high torque results.
It will go inactive when the next fastening is started (the torque exceeds the threshold value) or a Job reset.
Angle Ok
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Angle Ok” output assignment will go active at the completion of a fastening that has an acceptable angle
results. It will go inactive when the next fastening is started (the torque exceeds the threshold value) or a Job reset.
Angle Nok
Supported Feature
Bus Element
Bit
0-32
Polarity
N.O./N.C.
Mode
Normal, Timed, Flash
Time Width Offset
Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Angle Nok” output assignment will go active at the completion of a fastening that has an unacceptable angle
results. It will go inactive when the next fastening is started (the torque exceeds the threshold value) or a Job reset.