6
AcraDyne Gen IV iAC Controller Manual
3.1 Air and Electrical Connections
Step 1:
Connect the air components to the
controller and tool. (See: typical installation
configurations for the specific controller models
below)
Step 2:
Connect power cable to the # 5 power
supply plug. (See "2.1 Bottom Panel iAC Basic Model"
Step 3:
Connect sensor cable assembly to the IAC
controller connection #2. (See "2.1 Bottom Panel
Step 4:
Connect the sensor cable to the URYU tool
using the red mark to align pins correctly.
Step 5:
Plug male end of power cable into
appropriate power source
Step 6:
Connect 24V external solenoid valve to 24
volt terminal on controller
Step 7:
Connect power cable to the # 5 power
supply plug. (See "2.1 Bottom Panel iAC Basic Model"
Note:
Due to a variety of 230Vac power outlets,
the standard power cable plug-end provided with
the controller
may
need to be modified in order
to connect to local 230Vac power outlets. AIMCO
has a wide variety of country specific power cord
options available. Check with your authorized
AIMCO representatives to see if your specific
configuration is available. In any case, connection
to local power should be made in consultation with
a qualified electrician.
Step 8:
Turn controller on by pushing the Power
Disconnect Switch #4 to the POWER ON position
(see "2.1 Bottom Panel iAC Basic Model" on page
4). A light indicates power on.
3. Initial Setup
Typical Air Connections for Base Models
Gen IV iAC
Controller
Base Model
Tool Signal Cable
Shut-Off Valve
Solenoid
Cable
Filter
Manual Pressure
Regulator (set to
recommended
tool pressure)
Shutoff Valve
Solenoid
Controlled
Lubricator
Tool
Air Supply
Air
Line
Typical Air Connections for SR Models equipped with
Internal Shutoff Valve and Digital Pressure Regulator
Filter
Air Supply
130 PSI Maximum
Minimum pressure >10 PSI above
tool's recommended pressure
Gen IV iAC-SR
Controller
Lubricator
Tool
Air
Line
Tool Signal
Cable