10.2 24 Volt I/O Connections
Turn off system before connecting to the LOGIC I/O
port. There may be risk of damaging the controller.
•
24Vdc Supply:
The internal 24Vdc power can
supply up to 1 amp.
•
Inputs:
Inputs are a sinking configuration with the
common connected to the ground pins. 24Vdc is
logic ON and 0Vdc is logic OFF.
•
Outputs:
Outputs are normally open relay
contacts. The relays are rated for 24Vdc, 1 amp.
NOTE:
If Outputs are driving an inductive load, such
as a solenoid or large relay, it is recommended to
add a diode in parallel with the load to prevent
voltage surges.
10.1 Port Pinout and Diagrams
An I/O wiring adapter kit is available (Part #
27348
)
from AIMCO to make connection to I/O port on
the controller easier. Contact your AIMCO Sales
Representative for ordering information. Toll Free:
1-800-852-1368.
Pin # Function
Default Assignment
1
Output 1
Accept
2
Output 2
Reject
3
Output 3
In Cycle
4
Output 4
Torque High
5
Outputs
1-4 common
6
Input 1
N/C
7
Input 2
N/C
8
Input 3
Disable Tool
9
Input 4
PSet Bit 1
10
Input 5
PSet Bit 2
11
Input 6
PSet Bit 3
12
Input 7
Reset Job
13
Input 8
14
Output 5
Torque Low
15
Output 6
Angle High
16
Output 7
Angle Low
17
Output 8
Job Complete
18
Outputs
5-8 common
19
N/C
20
N/C
21
24 V Return
22
24 V Return
23
+24 Vdc
24
+24 Vdc
25
+24 Vdc
NOTE:
The Default Assignments in Table above are
factory defaults and can be changed. See "11.
10. 24 Volt I/O