AcraDyne Gen IV iAC Controller Manual
4.2.2 PSet Stages
4.2.2.1 TC_PM Torque Control Pulse Monitor
Torque High:
Upper control limit of the rundown.
Torque Target:
Final desired torque (CUT Level).
Torque Low:
The lower control limit of the rundown.
Pulse Bailout:
Total number of pulses never to be exceeded. Helps to
illustrate how far past Pulse High the rundown experienced without
damaging the part or excessively wearing the tool’s pulse fluid.
Pulse High:
Maximum acceptable pulses
Pulse Low:
Minimum acceptable pulses
Pulse Reference:
(drop down menu)
• In-cycle Pulse:
Monitoring number of tool Pulse begins after the tool
overcomes pre-set in-cycle Torque
• Stage Pulse:
Monitoring all Pulses specifically in the Stage
Additional Pulses:
After reaching target torque, additional pulses to be
applied before shutting of the air to the tool.
PSI:
Desired amount of air pressure supplied to the tool (Only available for
SR models). Note: The pressure set in the first stage of the PSet, is applied
when the tool is enabled to run.
Stage Timeout (s):
Maximum allowable time (in seconds) in this stage. If
time is exceeded, the tool will stop and the Rundown will be terminated.