Programming Command Reference
Power Control Level
TXANalyzer:PLEVel <int>
TXANalyzer:PLEVel?
This command sets a value of Power Control Level for each
radio system set by the
command described on
. The allowable range and preset values are as
follows:
Amplitude
TXANalyzer:AMPLitude <real>
TXANalyzer:AMPLitude?
This command sets the amplitude of output signal from the
Tester applied to the mobile phone under test. The allowable
range is from
-110.0
to
-20.0
(dBm) in
0.1
steps. At preset,
this is set to
-50.0
(dBm).
This query command returns the set amplitude of output signal
by real ranging from
-110.0
to
-20.0
(dBm).
MS Signal
TXANalyzer:SIGNal BURST|CW
TXANalyzer:SIGNal?
This command selects a signaling type from the mobile phone
for analysis. The parameter is
BURST
or
CW
. At preset, this is set
to
BURST
.
This query command returns the selected signal type with
strings of
BURST
or
CW
.
Table 5-44 Power Control Level Allowable Range and Preset Value
RFORmat
Allowable Range [Hz]
Preset Value [Hz]
GSM850
2 (+39 dBm) to 19 (+5 dBm)
5 (+33 dBm)
GSM900
2 (+39 dBm) to 19 (+5 dBm)
5 (+33 dBm)
DCS1800
0 (+30 dBm) to 15 (+0 dBm), or
29 (+36 dBm) to 31 (+32 dBm)
0 (+30 dBm)
PCS1900
0 (+30 dBm) to 15 (+0 dBm), or
30 (+33 dBm) to 31 (+32 dBm)
0 (+30 dBm)