5-124
N9360A Multi UE Tester GSM Programming Manual
5
Programming Command Reference
At preset, this is set to
1
×
1
.
This query command returns the test slot configuration for the
GPRS/EGPRS mode with strings. The variety of return strings is
same as that of the command parameter.
Measurement Slot
TESTs:MANual:MSLOt 2|3|4
TESTs:MANual:MSLOt?
This command selects the order of slot to be measured, on the
[Stand-by] screen for the GPRS/EGPRS mode, in conjunction
with the Slot Configuration setting. The combinations of the slot
order measured and the slot configuration are as follows:
Table 5-34 Slot Configuration and Slot Order Measured
Slot Configuration (Downlink
×
Uplink)
Slot Order Measured
1
× 1
2
2
× 1
3
2
× 2
2, 3
3
× 1
3
3
× 2
3, 4
4
× 1
4
N O T E
If the mode is set to GPRS/EGPRS, this command is valid.
Table 5-35 Slot Configuration and Slot Order Measured
Slot Configuration (Downlink
×
Uplink)
Slot Order Measured
1
× 1
2
2
× 1
3
2
× 2
2, 3
3
× 1
3
3
× 2
3, 4
4
× 1
4