The preset values of radio system and channel are 

GSM900

 and 

the Traffic Channel Number 1 respectively.

The setting of this command and the setting of the 

Talk Test 

TCH Frequency

 command changes synchronously.

This query command returns the set channel number of the 
Traffic Channel for Talk Test with integer. The range of the 
value is same as that of the command parameter.

BCCH Frequency

CONFigure:SEQuence:BCCH:FREQuency <int>

CONFigure:SEQuence:BCCH:FREQuency?

This command sets the frequency of Broadcast Control Channel 
(BCCH) for each radio system set by th

Radio System

 

command described on 

page 5-34

. The allowable range and 

preset values are as follows (in 200000 steps):

The setting of this command and the setting of the 

BCCH 

Channel

 command described on 

page 5-35

 changes 

synchronously.

This query command returns the set frequency of the Broadcast 
Control Channel with integer. The range of the value is same as 
that of the command parameter.

Table 5-5  BCCH Frequency Allowable Range and Preset Value

RFORmat

Allowable Range [Hz]

Preset Value [Hz]

GSM850

824200000 to 848800000

836200000

GSM900

876200000 to 889800000, 890000000 to 914800000

894000000

DCS1800

1710200000 to 1784800000

1747400000

PCS1900

1850200000 to 1909800000

1887400000

Summary of Contents for GS8210

Page 1: ...Agilent Technologies Agilent N9360A Multi UE Tester GSM Programming Manual ...

Page 2: ...bed in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or sub contract Software is delivered and licensed as Commercial computer soft ware as defined in DFAR 252 227 7014 defined in FAR 2 101 a or as Restricted computer softwa...

Page 3: ...en references Refer to the N9360A Multi UE Tester Installation Guide for information regarding installation and details of the tester Refer also to the N9360A W CDMA Programming Manual for information about the test functions of Wideband Code Division Multiple Access W CDMA This manual applies directly to the Tester with firmware revision F 02 14 and above Notation The following notations are used...

Page 4: ...l Basic are registered trademarks of Microsoft Corporation in the United States and or other countries cdma2000 is a registered trademark of Telecommunication Industry Association TIA USA Other product names and companies used herein are trademarks or registered trademarks of their respective companies or Agilent Technologies Inc For registered trademarks the trademarks symbols and are omitted in ...

Page 5: ... 61000 4 3 1996 3 V m 80 1000 MHz IEC 61000 4 4 1995 EN 61000 4 4 1995 0 5 kV signal lines 1 kV power lines IEC 61000 4 5 1995 EN 61000 4 5 1995 0 5 kV line line 1 kV line ground IEC 61000 4 6 1996 EN 61000 4 6 1996 3 V 0 15 80 MHz IEC 61000 4 11 1994 EN 61000 4 11 1994 1 cycle 100 Canada ICES 001 2004 Australia New Zealand AS NZS CISPR11 2004 The product was tested in a typical configuration with...

Page 6: ...ISPR11 2004 EMC IEC 61010 1 2001 EN 61010 1 2001 Canada CAN CSA C22 2 No 61010 1 04 Safety USA ANSI UL 61010 1 2004 Additional Information The product herewith complies with the essential requirements of the Low Voltage Directive 2006 95 EC and the EMC Directive 2004 108 EC and carries the CE Marking accordingly European Union 1 Performance Criteria A Pass Normal operation no effect B Pass Tempora...

Page 7: ...l 2 3 When Operating The Tester 2 4 3 Preparing for Use 3 1 Equipment for Automated Test System 3 2 Ethernet 3 2 GP IB 3 3 RS 232C Option E01 3 5 Connecting to Controller 3 6 Ethernet 3 6 GP IB 3 6 RS 232C 3 6 4 Programming Command Guideline 4 1 Getting Started with Programming Commands 4 2 Understanding common terms 4 2 Standard Notation 4 2 Command Syntax 4 3 Overview of the Ethernet Interface 4...

Page 8: ...creens 5 27 Command Reference for Signal Generator Screen 5 28 Command Reference for Configuration Screens 5 28 INITialsoftkey Subsystem 5 31 CONFigure Subsystem 5 32 CONFigure Subsystem Command Reference 5 32 Command Reference for Configuration Test Sequence Screen 5 34 Command Reference for Configuration Test Condition Screen 5 58 Command Reference for Configuration Test Condition Loss Screen 5 ...

Page 9: ... 5 164 TXANalyzer Subsystem 5 166 Command Reference for Stand by Measuring Screens 5 166 Command Reference for Peak TX Power Burst Timing Power Ramp Measurement Screen 5 172 Command Reference for Phase Frequency Error EVM Origin Offset Spr Measurement Screen 5 180 Command Reference for Output RF Spectrum Screen 5 185 Command Reference for Spectrum Monitor Measurement Screen 5 187 RFGenerator Subsy...

Page 10: ...se Error Frequency Error Screens 6 32 Sensitivity RX Quality RX Level Screens 6 32 Output RF Spectrum ORFS Screen 6 33 Spectrum Monitor Screens 6 34 SMS Screen 6 35 TX Analyzer Screens 6 36 Stand by Screens 6 36 Peak TX Power Burst Timing Power Ramp Screens 6 37 Phase Error Frequency Error Screens 6 39 ORFS Screen 6 39 Spectrum Monitor Screens 6 40 Signal Generator Screen 6 41 Print Screen Functio...

Page 11: ...N9360A Multi UE Tester GSM Programming Manual xi 8 Syntax Diagrams 8 1 Graphical Conversions 8 2 Syntax Diagrams 8 3 ...

Page 12: ...xii N9360A Multi UE Tester GSM Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Page 13: ... 4 7 Status Byte Register 4 20 Figure 4 8 Standard Event Status Register 4 21 Figure 4 9 Standard Event Status Enable Register 4 22 7 Sample Program 7 1 Figure 7 1 Sample Program Window 7 3 A Appendix A Syntax Diagrams A 1 Figure A 1 IEEE Common Commands A 3 Figure A 2 Top Menu Commands A 3 Figure A 3 Top Menu Commands Continued 2 A 4 Figure A 4 Top Menu Commands Continued 3 A 5 Figure A 5 DISPlay...

Page 14: ... A 23 Figure A 24 TESTs Subsystem for Manual Test A 24 Figure A 25 TESTs Subsystem for Manual Test Continued 2 A 25 Figure A 26 TESTs Subsystem for Manual Test Continued 3 A 26 Figure A 27 TESTs Subsystem for Manual Test Continued 4 A 27 Figure A 28 TESTs Subsystem for Manual Test Continued 5 A 28 Figure A 29 TX Analyzer Subsystem A 29 Figure A 30 TX Analyzer Subsystem Continued 2 A 30 Figure A 31...

Page 15: ...5 8 TCH Channel Allowable Range and Preset Value 5 40 Table 5 9 TCH Channel Expanded version Allowable Range 5 41 Table 5 10 MS Power Class Allowable Range and Preset Value 5 61 Table 5 11 Power Control Level Allowable Range and Preset Value 5 62 Table 5 12 Power Control Level Allowable Range and Preset Value 5 69 Table 5 13 Power Control Level Allowable Range and Preset Value 5 69 Table 5 14 RX Q...

Page 16: ... Preset Value 5 166 Table 5 43 RFCH Frequency Allowable Range and Preset Value 5 167 Table 5 44 Power Control Level Allowable Range and Preset Value 5 168 Table 5 45 The Lower Limit Value in GMSK 8PSK 5 178 Table 5 46 The Upper Limit Value in GMSK 8PSK 5 179 Table 5 47 Spectrum Monitor Measurement Result 5 188 Table 5 48 Spectrum Monitor Measurement Result 5 189 Table 5 49 RFCH Allowable Range and...

Page 17: ...mand Summary 6 36 Table 6 24 TX Analyzer TPOWer TXAMplitude Command Summary 6 37 Table 6 25 TX Analyzer Phase TXFRequency Command Summary 6 39 Table 6 26 ORFS Command Summary 6 39 Table 6 27 TX Analyzer SMONitor Command Summary 6 40 Table 6 28 RFGenerator Subsystem Command Summary 6 41 Table 6 29 HCOPy Subsystem Command Summary 6 42 Table 6 30 SYSTem Subsystem Command Summary 6 42 7 Sample Program...

Page 18: ...xviii N9360A Multi UE Tester GSM Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Page 19: ...1 1 Agilent Technologies 1 Legal Information Warranty 1 2 Technology Licenses 1 2 Restricted Rights Legend 1 2 Service And Support 1 3 Agilent On The Web 1 3 Agilent By Phone 1 3 ...

Page 20: ...erms in the separate agreement shall control Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or subcontract Software is delivered and licensed as Commercial compute...

Page 21: ... link to Test Measurement Select your country from the drop down menus The Web page that appears next has contact information specific for your country Agilent By Phone If you do not have access to the Internet call one of the numbers in Table 1 1 Table 1 1 Agilent Call Centers and Regional Headquarters Manufacturing Address Agilent Technologies Microwave Products Malaysia Sdn Bhd Bayan Lepas Free...

Page 22: ...1 4 N9360A Multi UE Tester GSM Programming Manual 1 Legal Information THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Page 23: ...2 1 Agilent Technologies 2 Caution and Safety Requirements Safety Summary 2 2 Safety Notices 2 2 Warning Label 2 3 General 2 3 When Operating The Tester 2 4 ...

Page 24: ...AUTION notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met WARNING A WARNING notice denotes a hazard It calls attention to an operating procedure practic...

Page 25: ...ide of the symbol Symbol indicates a mandatory action or an instruction The actual detail in this case remove the power plug from an outlet is indicated inside of the symbol WARNING The protection provided by the N9360A system may be impaired if the tester is used in a manner not specified by Agilent or the instructions on the display are not followed WARNING DO NOT INSTRUMENT COVERS Operating per...

Page 26: ...Tester CAUTION Make sure that the input signal level does not exceed the maximum level allowed Tester failure may result otherwise CAUTION Do not turn off the Line switch on the rear panel of the Tester while the LINE LED on the front panel of the Tester is lit in green Otherwise Tester failure may occur ...

Page 27: ...d Test System 3 2 Ethernet 3 2 GP IB 3 3 RS 232C Option E01 3 5 Connecting to Controller 3 6 Ethernet 3 6 GP IB 3 6 RS 232C 3 6 This chapter describes a quick overview of how to set up an automated test system with the Agilent N9360A Multi UE Tester GSM Test Capability ...

Page 28: ... the controller and the Tester directly Or two 10Base T 100Base TX UTP straight cables to connect a HUB the controller and the Tester An RF cable to connect the RF signal from or to the mobile phone under test the Antenna Coupler Agilent N9360A A02 to connect RF signal from or to the mobile phone to couple RF signal from or to the mobile phone A printer and an appropriate cable if required A typic...

Page 29: ...he GP IB interface An IEEE 488 GP IB cable An RF cable to connect the RF signal from or to the mobile phone under test the Antenna Coupler Agilent N9360A A02 to connect the RF signal from or to the mobile phone to couple the RF signal from or to the mobile phone A printer and an appropriate cable if required A typical setup for an automated test system using the GP IB as shown in Figure 3 2 below ...

Page 30: ...IB interface An IEEE 488 GP IB cable An RF cable to connect RF signal from to the mobile phone under test the Antenna Coupler Agilent N9360A A02 to connect RF signal from to the mobile phone or the Shield case Agilent N9360A S01 to couple RF signal from to the mobile phone A printer and an appropriate cable if required A typical setup for an automated test system using the GP IB interface looks li...

Page 31: ... 232C null modem cable An RF cable to connect RF signal from to the mobile phone under test the Antenna Coupler Agilent N9360A A02 to connect RF signal from to the mobile phone or the Shield case Agilent N9360A S01 to couple RF signal from to the mobile phone A printer and an appropriate cable if required A typical setup for an automated test system using RS 232C interface looks like the illustrat...

Page 32: ... IB connector use an IEEE 488 GP IB cable to connect the the controller and the Tester with the Option E00 Or use the USB GPIB converter option E02 and an IEEE 488 GP IB cable to connect the controller PC and the Tester RS 232C A DB 9 male connector option E01 is provided with the Tester as the serial interface to a controller If your controller PC has a serial interface refer the following explan...

Page 33: ...reparing for Use 3 N9360A Multi UE Tester GSM Programming Manual 3 7 An example of connection of these cable and adapter are shown in Figure 3 5 as follows Figure 3 5 RS 232C Cable and Adapter connection ...

Page 34: ...3 8 N9360A Multi UE Tester GSM Programming Manual 3 Preparing for Use THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Page 35: ...view of the Ethernet Interface 4 5 Overview of the GP IB Interface 4 8 Overview of the RS 232C Serial Interface 4 10 Programming Guidelines 4 13 Typical Programming Flow for the Tester 4 13 Using the Status Registers 4 16 Why Would You Use the Status Registers 4 16 Status Register System 4 19 Error Messages 4 23 This chapter contains a brief overview of the programming commands ...

Page 36: ... type of command Queries instruct the instrument to respond to the data available to the controller Query mnemonics always end with a question mark Preset A default value or status when the Tester is shipped from the factory or after pressing the Preset button Command Mnemonics Most of the commands have two forms a long form and a short form Use either long or short command form Combined form is n...

Page 37: ...follows the CONFigure portion of the statement with no separating space A separating space is legal only between the command and its argument In this example the portion following the PKEY is the argument Either UNLOCK or LOCK must be selected Additional notation used in the syntax statements are defined as follows vertical bar indicates a choice of one element from a list For example A B indicate...

Page 38: ...0 question mark following a command indicates that the command is a query Most of the commands accept the query command To make the query command a question mark is following to the command The returned information value varies in format according to the type of the command continue indicates the line does not end and continue to the next line For example ABC DEF Is same as follows ABC DEF In addi...

Page 39: ...able range are as follows The terminator outputted from the Tester can be changed as specified in Table 4 1 The terminator inputted to the Tester is LF fixed The TCP port number is 10123 fixed User cannot use the address from 192 168 1 1 to 192 168 1 255 as it is already used by the Tester Refer to the following procedure to set the Ethernet configuration Table 4 1 Ethernet configuration Item Pres...

Page 40: ... screen press the Config softkey to obtain the Configuration screen The Terminator input field is set on this screen Figure 4 1 Network Setting Screen Ethernet Interface Step 2 On the configuration screen press the Network Setting softkeys to obtain the Network Setting screen Set the Ethernet setting parameters on this screen ...

Page 41: ...e 4 N9360A Multi UE Tester GSM Programming Manual 4 7 Figure 4 2 Network Setting Screen Ethernet Interface Step 3 Confirm that the Ethernet configurations are correct Step 4 Press the Apply Address softkey to activate the setting ...

Page 42: ...et using the User Interface The preset settings and allowable range are as follows The terminator outputted from the Tester can be changed as specified in Table 4 2 The terminator inputted to tester is LF for GPIB option E02 The terminator inputted to tester is CR LF for GPIB option E00 If EOI is set to On the terminator is not transmitted Refer to the following procedure to set the GP IB configur...

Page 43: ... 9 Step 1 On the Top Menu screen or the Initial screen press the Config softkey to obtain the Configuration screen Figure 4 3 Configuration Screen GP IB Interface Step 2 Confirm that the GP IB configurations are correctly set Step 3 Reboot the Tester to activate the configuration ...

Page 44: ... Interface The preset settings and allowable range are as follows The terminator outputted from the Tester can be change as specified in Table 4 3 The terminator inputted to tester is LF for GPIB option E02 The terminator inputted to tester is CR LF for GPIB option E00 Refer to the following procedure to set the serial port configuration Table 4 3 Serial Port Configuration Item Preset Other Choice...

Page 45: ...Step 1 On the Top Menu screen or the Initial screen press the Config softkey to obtain the Configuration screen Figure 4 4 Configuration Screen RS 232C Interface Step 2 Confirm that the Serial Port configurations are correctly set Step 3 Reboot the Tester to activate the configuration ...

Page 46: ...oller receives the Xon decimal value of 17 resume transmitting data Flow control using the control lines CTS DSR and DCD are not available Data Transfer Errors On the serial interface several type of errors may occur during data reception The errors may occur by any of the following factor Parity error The parity bit on a receiving character does not match the parity bit expected by the receiver T...

Page 47: ...y Bit Bit 0 and the Measuring Status Bit Bit 1 When testing by the Automatic Test mode or the Manual Test mode wait until the step of the Test flow ends To check the status of the Test flow send the TESTs AUTO MEASure SIGNaling STATe query command when the test mode is the Automatic Test mode or send the TESTs MANual SIGNaling STATe query command when the test mode the Manual Test mode Typical Pro...

Page 48: ... RFOR DCS1800 Step 5 Create an instruction message as follows for the operator to turn on the mobile phone and wait for the Location Update to complete Display Message on the PC screen Turn on the mobile phone and wait to finish the Location Update Then press OK Wait until the OK button on the PC screen is clicked on Step 6 Start the BS Call and then check that the test flow changes to the Talk RF...

Page 49: ... next step Step 9 Read the Peak TX Power test results for example Send Query Command to the Tester TEST MAN RES TXP Display Message on the PC Peak TX Power Value 3 dBm Display Message on the PC If the Value 2 is not 0 Message is FAIL Else Message is PASS Step 10 Start the BS Release for example Send Command to the Tester TEST MAN BSR Send Query Command to the Tester TEST MAN SIGN STAT If the Respo...

Page 50: ...ing the status register system Individual status registers can be set and queried using the commands in the IEEE common commands reference A status register is actually composed of five physical registers one condition register two transition registers one event enable register and one event register However the Standard Event Status Register is composed of an event enable register and an event re...

Page 51: ...and clearing all the event registers ESE ESE event status enable sets and queries the bits in the enable register part of the standard event status register ESR event status register queries and clears the event register part of the standard event status register This command will be added in future OPC OPC operation complete sets the standard event status register to monitor the completion of all...

Page 52: ...ble a particular bit you need to send this value with the command If you want to enable more than one bit send the sum of all the bits that you want to enable Figure 4 5 Bit Values For example to set 1 to bit 0 and bit 6 of the Standard Event Status Register send the command ESE 65 1 64 The result of a query is evaluated in a similar way If the command STB returns a decimal value of 140 128 8 4 th...

Page 53: ...ng Manual 4 19 Status Register System Figure 4 6 shows all of the instrument status registers and their hierarchy incorporated with the Tester Figure 4 6 Overall Status Byte Register System Each of these status registers is explained in detail in the following sections ...

Page 54: ... example if the bit 5 and bit 4 are set to 1 the decimal sum of these 2 bits is 48 32 plus 16 see Figure 4 5 So the decimal value 48 is returned Table 4 4 Status Byte Register Bit Description 0 0 Measurement data is not ready in the output queue 1 Measurement data is ready in the output queue 1 0 Measurement is completed 1 Measurement is not completed 2 3 These bits are always set to 0 4 0 Measure...

Page 55: ...ese 2 bits is 136 128 plus 8 see Figure 4 5 So the decimal value 136 is returned Table 4 5 Status Byte Register Bit Description 0 If all pending operations is completed following execution of the OPC command this bit is set to 1 1 This bit is always set to 0 2 If a query error has occurred this bit is set to 1 3 If a device dependent error has occurred this bit is set to 1 Device dependent errors ...

Page 56: ... information of the Standard Event Status Register to bit 5 of the Status Byte Register set 1 to corresponding bit of the Standard Event Status Enable Register Send the ESE int command where int is the sum of the decimal values of the bits you want to enable For example to inform the Power On and Command Error bits information to the bit 5 of the Status Byte Register bit 7 and 5 are set to 160 by ...

Page 57: ... due to a program mnemonic is too long 113 Command error due to an undefined header 120 Command error due to a numeric data error 123 Command error due to an exponent is too large 124 Command error due to too many digits 131 Command error due to an invalid suffix 141 Command error due to invalid character data 144 Command error due to character data is too long 200 Execution error due to an invali...

Page 58: ...4 24 N9360A Multi UE Tester GSM Programming Manual 4 Programming Command Guideline THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Page 59: ...ubsystem for Manual Test 5 118 TXANalyzer Subsystem 5 166 RFGenerator Subsystem 5 190 HCOPy Subsystem 5 194 SYSTem Subsystem 5 195 TRIGger Subsystem 5 197 This chapter describes all commands of syntaxes parameters and response Some commands are valid only for corresponding mode GSM GPRS and EGPRS Be sure that the mode is set correctly before executing each command The Option G03 should be installe...

Page 60: ... manufacturer name model number serial number and the revision number of the firmware Reset RST This command executes the self test routine and resets the Tester to the initial state Operation Complete OPC OPC This command sets or queries the OPC bit bit0 of the Standard Event Status Register SESR The query command returns 1 Clear Status CLS This command initializes the Status Byte Register STBR a...

Page 61: ... bit 0 1 Operation Complete bit 1 2 Unused bit 2 4 Query Error bit 3 8 Device Dependent Error bit 4 16 Execution Error bit 5 32 Command Error bit 6 64 Unused bit 7 128 Power On For detailed information refer to Standard Event Status Register on page 4 21 Standard Event Status Enable ESE int ESE This command sets or queries a value of the Standard Event Status Enable Register SESER The allowable ra...

Page 62: ...t 0 1 Measurement Data Ready bit 1 2 Measuring Status bit 2 4 Unused bit 3 8 Unused bit 4 16 Message Available bit 5 32 Standard Event Status Summary bit 6 64 Unused bit 7 128 Unused For detailed information refer to Status Byte Register on page 4 20 Instrument Option Query OPT This query command returns a value of the option numbers installed in the Tester Selftest Result Query TST This query com...

Page 63: ...mmands System Error SYSTem ERRor This query command returns a set of values int 1 and string 2 for error numbers and error messages Refer to Table 4 6 on page 4 23 Lock System Panel SYSTem KLOCk ON OFF 1 0 SYSTem KLOCk This command sets all the panel keys setting to ON 1 or OFF 0 If this is set to ON or 1 all the panel keys are locked If this is set to OFF or 0 all the panel keys are unlocked At p...

Page 64: ...uration Screen UPDA FIRM Firmware Update Screen UPDA FLAS Update Flash Screen ELSE The other screens enum2 is displayed 0 is returned Top Menu Screen DISPlay INIT This command selects the Top Menu screen for activating one of the function modes System Configuration DISPlay CONFigure This command selects the Configuration screen NOTE The parameters of the serial interface and the GP IB interface ar...

Page 65: ...work Setting screen Firmware Update Screen DISPlay UPDAte FIRMware This command selects the Firmware Update screen Update Flash Screen DISPlay UPDAte FLASh This command selects the Update Flash screen This is available only when the Option C03 is installed in the Tester Application Type DISPlay APPLication This command returns the type of application currently in operation ...

Page 66: ...ial screen of the W CDMA mode W00 option is required to install in the Tester For detailed information about the programming command of the W CDMA mode refer to the Agilent N9360A W CDMA Programming Manual APPLication CDMA This command selects the cdma2000 Function Tester application N9360A FUNC and displays the Initial screen of the cdma2000 mode C00 and C01 options are required to install in the...

Page 67: ... This command sets the output direction of the Print Screen The choices are PMG800 and USBMemory At preset this is set to USBMemory This query command returns the output direction of the Print Screen with strings Beeper Control CONFigure BEEPer ON OFF 1 0 CONFigure BEEPer This command sets the beep function to ON 1 or OFF 0 If this is set to ON there is beep for each step of operation If this is s...

Page 68: ...nt MM int DD CONFigure DATE This command sets the date of the calendar in the Tester int YYYY is year within the range from 1990 to 2037 int MM is month within the range from 1 to 12 and int DD is day within the range from 1 to 31 This query command returns the date of the calendar in the Tester with int YYYY int MM and int DD The range of these values is same as that of the command parameter Time...

Page 69: ... CDMA application or the cdma2000 application respectively G00 option is required to install in the Tester to boot GSM W00 option is required to install in the Tester to boot WCDMA C00 and C01 options are required to install in the Tester to boot cdma2000 The duration time is within the ranges from 10 to 60 seconds in 1 steps At preset these settings are NONE and 10 which means the Tester does not...

Page 70: ... CONFigure NETwork IPaddress CONFigure NETwork DEFault GATEway CONFigure NETwork GATEway SET1 to SET5 IP Address CONFigure NETwork IPaddress string int CONFigure NETwork IPaddress This command sets the IP address and the subnet mask address of the Tester string specifies the IP address ranging from 1 0 0 1 to 223 255 255 255 But from 192 168 1 1 to 192 168 1 1255 are unavailable to use the IP addr...

Page 71: ...s when enum is set to ACT This returns NONE only when enum is set to NONE Setting 1 to 5 Gateway Address CONFigure NETwork GATEway SET1 enum 1 string 1 enum 2 string 2 CONFigure NETwork GATEway SET1 CONFigure NETwork GATEway SET2 enum 1 string 1 enum 2 string 2 CONFigure NETwork GATEway SET2 CONFigure NETwork GATEway SET3 enum 1 string 1 enum 2 string 2 CONFigure NETwork GATEway SET3 CONFigure NET...

Page 72: ...the CIDR form ranging from 1 to 31 string2 specifies the gateway address The allowable range of each parameter is as follows These query commands return the set values Table 5 1 Setting 1 to 5 Gateway Address Allowable Range enum1 enum2 string1 string2 ACT NONE 1 0 0 1 to 223 255 255 255 Host specifying address 192 168 1 1 to 192 168 1 255 are unavailable to use 1 0 0 1 to 223 255 255 Gateway addr...

Page 73: ...t to USB This query command returns the update type USB HDD or SERVER setting with strings Update Result UPDAte RESult This query command returns the set of values int 1 int 2 int 3 int 4 string 1 string 2 USB HDD SERVER as a result of last update int 1 1 digit is the existance of update result for the exist 1 or not exist 0 int 2 4 digit is the year by which update was carried out with yyyy int 3...

Page 74: ...yyy int 3 2 digit is the month by which update was carried out with mm int 4 2 digit is the day by which upadate was carried out with dd string 1 32 letters is the version number of archive string 2 4 letters is the result code of update If update is a failure it is equivalent to the error code If update is a success it is 0000 USB HDD SERVER is the update type Update History Position UPDAte HISTo...

Page 75: ...mand parameter Update History Number UPDAte HISTory NUMber This query command returns the total number of the existing update history HDD Clear File UPDAte HDD CLEar FILE This command carries out deletion of the archive files for the HDD update It is effective only when the Update Type is set to HDD Server IP Address UPDAte SERver IPaddress string UPDAte SERver Ipaddress This command sets the IP a...

Page 76: ...ester SYS is system of tester Update Top Menu Firmware List UPDAte FIRMware LIST MENU This query command returns the version of the archive file for update of the application applicable to the top menu which the tester recognizes The format of archive file is MENU_M xx xx or MENU_M xx xx yy x numeric character y alphanumeric character It returns if the tester is no recognized archive file Update F...

Page 77: ...ter recognizes This is effective only for W00 option installed tester The format of archive file is W00_W xx xx or W00_W xx xx yy x numeric character y alphanumeric character It returns if the tester is no recognized archive file Update System List UPDAte FIRMware LIST SYStem This query command returns the version of the archive file for update of the application applicable to the system setting w...

Page 78: ...is query command returns the version of the G00 tester which is indtalled in the tester This is effective only for G00 option installed tester The format of revision is G00_G xx xx or G00_G xx xx yy x numeric character y alphanumeric character It returns if the tester is no recognized archive file W00 Mode Firmware Revision UPDAte FIRMware REVision W00 This query command returns the version of the...

Page 79: ... recognizes The format of archive file is MC1X xx xx or MC1X xx xx yy x numeric character y alphanumeric character It returns if the tester is no recognized archive file Update 1xEV DO Flash List UPDAte FLASh LIST 1XEVDO This query command returns the version of the archive file which updates 1xEV DO Flash ROM which the tester recognizes The format of archive file is EVDO xx xx or EVDO xx xx yy x ...

Page 80: ...sh ROM Revision UPDAte FLASh REVision 1XEVDO This query command returns the revision of the 1xEV DO Flash ROM which is installed in the tester The format of revision is EVDO xx xx or EVDO xx xx yy x numeric character y alphanumeric character It returns if the tester is no recognized archive file ...

Page 81: ...est Peak TX Power Burst Timing Power Ramp screen MAN PHAS Manual Test Phase Error Frequency Error screen MAN SENS Manual Test Sensitivity RX Quality RX Level screen MAN SMON Manual Test Spectrum Monitor screen MAN SMS Manual Test SMS screen MAN ORFS Manual Test ORFS screen TXAN STBY TX Analyzer Stand by screen TXAN TPOW TX Analyzer Peak TX Power Burst Timing Power Ramp screen TXAN PHAS TX Analyzer...

Page 82: ...s returned Initial Screen DISPlay INIT This command selects the Initial screen Display fast mode DISPlay MODE FAST TRACk DISPlay MODE This command sets the display mode FAST is fast mode TRACk is normal mode It cannot set up during testing of Automatic Test signaling and mesurement state of Manual Test and measurement state of Tx Analyzer If FAST mode is specified since renewal of a screen is not ...

Page 83: ...rameter specifies the Channel Number Burst Timing Power Ramp DISPlay AUTO TPOWer 1 2 3 4 5 6 This command selects the Automatic Test Burst Timing Power Ramp screen The parameter specifies the Channel Number Phase Error Frequency Error DISPlay AUTO PHASe 1 2 3 4 5 6 This command selects the Automatic Test Phase Error Frequency Error screen The parameter specifies the Channel Number Sensitivity RX Q...

Page 84: ...the Manual Test Peak TX Power Burst Timing Power Ramp screen Phase Error Frequency Error DISPlay MANual PHASe This command selects the Manual Test Phase Error Frequency Error screen Sensitivity RX Quality RX Level DISPlay MANual SENSitivity This command selects the Manual Test Sensitivity RX Quality RX Level screen Spectrum Monitor DISPlay MANual SMONitor This command selects the Manual Test Spect...

Page 85: ...TX Analyzer Stand by screen Peak TX Power Burst Timing Power Ramp DISPlay TXANalyzer TPOWer This command selects the TX Analyzer TX Power Ramp screen Phase Error Frequency Error DISPlay TXANalyzer PHASe This command selects the TX Analyzer Phase Error Frequency Error screen Spectrum Monitor DISPlay TXANalyzer SMONitor This command selects the TX Analyzer Spectrum Monitor screen Output RF Spectrum ...

Page 86: ...the Signal Generator screen Command Reference for Configuration Screens System Configuration DISPlay CONFigure This command selects the Configuration screen The parameters and controls on this screen set the fundamental information for all function modes of the Tester NOTE The parameters for the serial andGP IB are manually specifiable The Ethernet parameters are specifiable in the program ...

Page 87: ...command selects the Configuration Test Condition Linit screen The parameters and controls on this screen set the test conditions of Automatic Test and Manual Test DISPlay CONFigure CONDition BA This command selects the CONFIGURATION Test Setup Test Condition BA Table screen Test Sequence DISPlay CONFigure SEQuence This command selects the Configuration Test Sequence screen The parameters and contr...

Page 88: ...5 30 N9360A Multi UE Tester GSM Programming Manual 5 Programming Command Reference Network Setting Screen DISPlay CONFigure NETwork This command selects the Configuration Network Setting screen ...

Page 89: ...nd parameters on the Initialsoftkey screen Current System INITialsoftkey CURrentsystem WCDMA GSM CDMA2000 INITialsoftkey CURrentsystem This command selects the target system of operation Selecting WCDMA opens the W CDMA System Setting screen Likewise GSM and CDMA2000 open the GSM System Setting screen and the CDMA2000 System Setting screen respectively ...

Page 90: ...and warnings At preset this is set to 1 This query command returns the beep setting with integer value of 1 or 0 10MHz Reference Oscillator CONFigure ROSCillator This query command returns the reference signal setting with string of INT or EXT Date CONFigure DATE int YYYY int MM int DD CONFigure DATE This command sets the default of the calendar in the Tester int YYYY is year within the range from...

Page 91: ...or LOCK At preset this is set to UNLOCK If this is set to LOCK only Automatic Test and Configuration are available In Automatic Test Radio System BCCH and TCH Talk are locked and cannot be changed This command is not identical to Lock System Panel of the System commands See Lock System Panel on page 5 5 This query command returns the panel key control setting by string of UNLOCK or LOCK Printer Co...

Page 92: ...e RFORmat This command selects a Radio System to be tested The parameter is W CDMA GSM850 GSM900 DCS1800 PCS1900 CDMA2000MC1X CDMA2000EVDO or OFF At preset this is set to GSM900 W CDMA is available when the W00 option is installed CDMA2000MC1X is available when the C00 and C01 options are installed CDMA2000EVDO is available when both the C00 C01 and C02 options are installed This query command ret...

Page 93: ...ble range and preset values are as follows The setting of this command and the setting of the BCCH Frequency command described on page 5 37 changes synchronously This query command returns the set channel number of the Broadcast Control Channel with integer The range of the value is same as that of the command parameter Table 5 2 BCCH Channel Allowable Range and Preset Value RFORmat Allowable Rang...

Page 94: ...ge of the value is same as that of the command parameter CONFigure SEQuence TCH CHANnel EXPand enum int CONFigure SEQuence TCH CHANnel EXPand This command sets the Traffic Channel number TCH of Talk test for arbitrary radio system enum is the Radio System Channel Number int is the Channel Number of the Traffic Channel Number The allowable range and preset values are as follows Table 5 3 TCH Channe...

Page 95: ...s the frequency of Broadcast Control Channel BCCH for each radio system set by the Radio System command described on page 5 34 The allowable range and preset values are as follows in 200000 steps The setting of this command and the setting of the BCCH Channel command described on page 5 35 changes synchronously This query command returns the set frequency of the Broadcast Control Channel with inte...

Page 96: ...integer The range of the value is same as that of the command parameter CONFigure SEQuence TCH FREQuency EXPand enum int CONFigure SEQuence TCH FREQuency EXPand This command sets the Traffic Channel TCH frequency of Talk test for arbitrary radio system enum is the Radio System Channel Frequency int is the Channel Number of the Traffic Channel Frequency The allowable range and preset values are as ...

Page 97: ...H Channel CONFigure SEQuence VARiable TCH CHANnel1 int CONFigure SEQuence VARiable TCH CHANnel1 CONFigure SEQuence VARiable TCH CHANnel2 int CONFigure SEQuence VARiable TCH CHANnel2 CONFigure SEQuence VARiable TCH CHANnel3 int CONFigure SEQuence VARiable TCH CHANnel3 CONFigure SEQuence VARiable TCH CHANnel4 int CONFigure SEQuence VARiable TCH CHANnel4 CONFigure SEQuence VARiable TCH CHANnel5 int C...

Page 98: ...er of the Traffic Channel for measurement test with integer The range of the value is same as that of the command parameter CONFigure SEQuence VARiable TCH CHANnel1 EXPand enum int CONFigure SEQuence VARiable TCH CHANnel1 EXPand CONFigure SEQuence VARiable TCH CHANnel2 EXPand enum int CONFigure SEQuence VARiable TCH CHANnel2 EXPand CONFigure SEQuence VARiable TCH CHANnel3 EXPand enum int CONFigure...

Page 99: ...igure SEQuence VARiable TCH CHANnel6 EXPand These six commands set each Traffic Channel number TCH for the measurement tests for arbitrary radio system If the parameter is set to NONE or 9999 the measurement test is skipped is shown in the table cell The allowable range are as follows The preset values of radio system and frequency are GSM900 and 890200000 Hz respectively Table 5 9 TCH Channel Exp...

Page 100: ...int sets whether to execute this test on each Traffic Channel by the total sum of 6 bits as follows bit 0 1 Testing on the TCH1 bit 1 2 Testing on the TCH2 bit 2 4 Testing on the TCH3 bit 3 8 Testing on the TCH4 bit 4 16 Testing on the TCH5 bit 5 32 Testing on the TCH6 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 The set of eac...

Page 101: ...total sum of the 6 bits as follows bit 0 1 Testing on the TCH1 bit 1 2 Testing on the TCH2 bit 2 4 Testing on the TCH3 bit 3 8 Testing on the TCH4 bit 4 16 Testing on the TCH5 bit 5 32 Testing on the TCH6 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 The set of each bit is 1 for Run and 0 for skip At preset this is set to 63 Thi...

Page 102: ...l sum of the 6 bits as follows bit 0 1 Testing on the TCH1 bit 1 2 Testing on the TCH2 bit 2 4 Testing on the TCH3 bit 3 8 Testing on the TCH4 bit 4 16 Testing on the TCH5 bit 5 32 Testing on the TCH6 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 The set of each bit is 1 for Run and 0 for skip At preset this is set to 63 This qu...

Page 103: ...hannel by the total sum of the 6 bits as follows bit 0 1 Testing on the TCH1 bit 1 2 Testing on the TCH2 bit 2 4 Testing on the TCH3 bit 3 8 Testing on the TCH4 bit 4 16 Testing on the TCH5 bit 5 32 Testing on the TCH6 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 The set of each bit is 1 for Run and 0 for skip At preset this is...

Page 104: ...by the total sum of the 6 bits as follows bit 0 1 Testing on the TCH1 bit 1 2 Testing on the TCH2 bit 2 4 Testing on the TCH3 bit 3 8 Testing on the TCH4 bit 4 16 Testing on the TCH5 bit 5 32 Testing on the TCH6 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 The set of each bit is 1 for Run and 0 for skip At preset this is set to...

Page 105: ... the total sum of the 6 bits as follows bit 0 1 Testing on the TCH1 bit 1 2 Testing on the TCH2 bit 2 4 Testing on the TCH3 bit 3 8 Testing on the TCH4 bit 4 16 Testing on the TCH5 bit 5 32 Testing on the TCH6 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 The set of each bit is 1 for Run and 0 for skip At preset this is set to 6...

Page 106: ...fic Channel by the total sum of the 6 bits as follows bit 0 1 Testing on the TCH1 bit 1 2 Testing on the TCH2 bit 2 4 Testing on the TCH3 bit 3 8 Testing on the TCH4 bit 4 16 Testing on the TCH5 bit 5 32 Testing on the TCH6 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 The set of each bit is 1 for Run and 0 for skip At preset th...

Page 107: ...ffic Channel by the total sum of the 6 bits as follows bit 0 1 Testing on the TCH1 bit 1 2 Testing on the TCH2 bit 2 4 Testing on the TCH3 bit 3 8 Testing on the TCH4 bit 4 16 Testing on the TCH5 bit 5 32 Testing on the TCH6 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 The set of each bit is 1 for Run and 0 for skip At preset t...

Page 108: ... total sum of the 6 bits as follows bit 0 1 Testing on the TCH1 bit 1 2 Testing on the TCH2 bit 2 4 Testing on the TCH3 bit 3 8 Testing on the TCH4 bit 4 16 Testing on the TCH5 bit 5 32 Testing on the TCH6 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 The set of each bit is 1 for Run and 0 for skip At preset this is set to 63 Th...

Page 109: ...tal sum of the 6 bits as follows bit 0 1 Testing on the TCH1 bit 1 2 Testing on the TCH2 bit 2 4 Testing on the TCH3 bit 3 8 Testing on the TCH4 bit 4 16 Testing on the TCH5 bit 5 32 Testing on the TCH6 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 The set of each bit is 1 for Run and 0 for skip At preset this is set to 63 This ...

Page 110: ... 2 real 3 real 4 CONFigure SEQuence LOSS RFIN CHANnel4 CONFigure SEQuence LOSS RFIN CHANnel5 real 1 real 2 real 3 real 4 CONFigure SEQuence LOSS RFIN CHANnel5 CONFigure SEQuence LOSS RFIN CHANnel6 real 1 real 2 real 3 real 4 CONFigure SEQuence LOSS RFIN CHANnel6 These six channels set the RF input path losses at each channel for the radio systems GSM850 GSM900 DCS1800 and PCS1900 respectively The ...

Page 111: ...l 2 real 3 real 4 CONFigure SEQuence LOSS RFOUT CHANnel4 CONFigure SEQuence LOSS RFOUT CHANnel5 real 1 real 2 real 3 real 4 CONFigure SEQuence LOSS RFOUT CHANnel5 CONFigure SEQuence LOSS RFOUT CHANnel6 real 1 real 2 real 3 real 4 CONFigure SEQuence LOSS RFOUT CHANnel6 These six commands set the RF output path losses at each channel for the radio systems GSM850 GSM900 DCS1800 and PCS1900 respective...

Page 112: ...CALL1 TYPE MS BS CONFigure SEQuence SIGNaling CALL1 TYPE This command sets the first caller at the second step in the test flow The parameter is MS or BS At preset this is set to MS This query command returns the set of first caller by string of MS or BS The meaning of the return value is same as that of the command parameter 1st Call Test CONFigure SEQuence SIGNaling CALL1 ON OFF 1 0 CONFigure SE...

Page 113: ...mat is not Off Talk Test CONFigure SEQuence SIGNaling TALK ON OFF 1 0 CONFigure SEQuence SIGNaling TALK This command sets whether to execute the Talk test in the test flow The parameter is ON 1 for Run or OFF 0 for skip At preset this is set to 1 This query command returns the set of Talk test by integer value of 1 or 0 The meaning of the return value is same as that of the command parameter RF Te...

Page 114: ... 1 0 CONFigure SEQuence SIGNaling CALL2 This command sets whether to execute the second call in a test flow The parameter is ON 1 for Run or OFF 0 for skip At preset this is set to 1 This query command returns the set of second call test with integer value of 1 or 0 The meaning of the return value is same as that of the command parameter 2nd Release Type CONFigure SEQuence SIGNaling REL2 TYPE MS B...

Page 115: ...tput Mode CONFigure SEQuence RFOUtput AUTO ON CONFigure SEQuence RFOUtput This command sets the RF Output in Automatic Test The parameter is AUTO or ON At preset this is set to ON This query command returns the set of RF Output with strings of AUTO or ON 3GPP system CONFigure SEQuence 3GPPsystem int CONFigure SEQuence 3GPPsystem This command sets the 3GPP system The allowable range is from 1 to 5 ...

Page 116: ...nd selects the target system of operation Selecting WCDMA opens the W CDMA System Setting screen Likewise GSM and CDMA2000 open the GSM System Setting screen and the CDMA2000 System Setting screen respectively Mode CONFigure CONDition MODE STD GPRS EGPRS CONFigure CONDition MODE This command sets the mode type to STD GSM GPRS or EGPRS At preset this is set to STD This query command returns the mod...

Page 117: ...CONFigure CONDition NETWork MCC int CONFigure CONDition NETWork MCC This command sets the Mobile Country Code MCC The allowable range is from 0 to 999 At preset this is set to 1 This query command returns the set Mobile Country Code with integer The range of the value is same as that of the command parameter MNC Mobile Network Code CONFigure CONDition NETWork MNC int CONFigure CONDition NETWork MN...

Page 118: ...ork LAC int CONFigure CONDition NETWork LAC This command sets the Location Area Code LAC The allowable range is from 0 to 65535 At preset this is set to 1 This query command returns the set Location Area Code with integer The range of the value is same as that of the command parameter BS PA Number of Multiframes CONFigure CONDition NETWork BSPA int CONFigure CONDition NETWork BSPA This command set...

Page 119: ...an execution error is warned even when the number may be within the effective setting range MS Power Class CONFigure CONDition PCLass int CONFigure CONDition PCLass This command sets a value of MS Power Class for each radio system set by the Radio System command described on page 5 34 The allowable range and preset values are as follows This query command returns the set MS power class with intege...

Page 120: ...nges for Automatic Test and Manual Test for each radio system set by the Radio System command described on page 5 34 The allowable range and preset values are as follows This query command returns the set Power Control Level with integer The range of the value is same as that of the command parameter Table 5 11 Power Control Level Allowable Range and Preset Value RFORmat Allowable Range Preset Val...

Page 121: ...ONDition AVERage This command selects whether to activate the Averaging The parameter is OFF or int for the number of averaging times The allowable range of int is from 2 to 200 At preset this is set to OFF This query command returns the set averaging BS Level CONFigure CONDition AMPLitude real CONFigure CONDition AMPLitude This command sets the amplitude BS Level of the output signal from the Tes...

Page 122: ...CS1900 or 100 0 dBm for DCS1800 This query command returns the set amplitude of output signal for error ratio tests with real The range of the value is same as that of the command parameter BER Frames BER GSM Mode Test Mode A CONFigure CONDition SENSitivity FRAMe int CONFigure CONDition SENSitivity FRAMe FAST BER GSM Mode Test Mode C CONFigure CONDition SENSitivity FRAMe BERFast int CONFigure COND...

Page 123: ...ge is from 1 to 13000 frames in 1 step size At preset this is set to 10 frames Loopback Delay CONFigure CONDition LDELay SHORT MID LONG CONFigure CONDition LDELay This command sets loopback delay The parameter is SHORT MID or LONG At preset this is set to MID This query command returns the set loopback delay with strings of SHORT MID or LONG NOTE Set the GSM mode GSM GPRS or EGPRS and the Test mod...

Page 124: ...gure CONDition CSCHeme Egprs MCS1 MCS2 MCS3 MCS4 MCS5 MCS6 MCS7 MCS8 MCS9 CONFigure CONDition CSCHeme Egprs This command sets the Coding Scheme for EGPRS test The allowable range is MCS1 MCS2 MCS3 MCS4 MCS5 MCS6 MCS7 MCS8 and MCS9 Puncturing Scheme CONFigure CONDition PUNCturing P1 P2 P3 CONFigure CONDition PUNCturing This command sets the EGPRS Puncturing Scheme The allowable range is P1 P2 and P...

Page 125: ...his command sets EVM Meas Count for EGPRS mode The allowable range is from 1 to 200 At preset this is set to 1 Location Update Delay CONFigure CONDition LOCupdatedelay int CONFigure CONDition LOCupdatedelay This command sets the delay time after completion of location update The allowable range is from 0 to 9 At preset this is set to 0 This query command returns the set location update delay with ...

Page 126: ... A B and SRB for EGPRS At preset GSM mode is set to A and GPRS and EGPRS mode is set to ACK Connection Wait Time CONFigure CONDition CONnectionwait int CONFigure CONDition CONnectionwait This command sets Connection Wait Time of MS Call The allowable range is from 0 to 120 At preset this is set to 0 Power Control Level Limit CONFigure CONDition LIMit TXPower PLEVel int CONFigure CONDition LIMit TX...

Page 127: ...B in 0 1 steps At preset these are set to 3 0 and 3 0 dB This query command returns the set power control level with integer and low and high limits for Peak TX Power test with real separated by a comma The range is same as that of the command parameter Table 5 12 Power Control Level Allowable Range and Preset Value RFORmat Allowable Range Preset Value GSM850 2 39 dBm to 19 5 dBm 5 29 dBm GSM900 2...

Page 128: ...e as that of the command parameter Phase Error Limit CONFigure CONDition LIMit PHASe RMS real HI CONFigure CONDition LIMit PHASe RMS CONFigure CONDition LIMit PHASe PEAK real HI CONFigure CONDition LIMit PHASe PEAK These commands set the high limit for Phase Error RMS and a parit of the low and high limits for Phase Error Peak tests The allowable range is from 0 0 to 99 9 in 0 1 steps At preset th...

Page 129: ... same as that of the command parameter RX Quality Limit CONFigure CONDition LIMit QUALity int LO int HI CONFigure CONDition LIMit QUALity This command sets the low and high limits for RX Quality test The parameter is 0 0 2 1 0 2 to 0 4 6 6 4 to 12 8 or 7 12 8 At preset these are set to 0 and 4 This query command returns the set low and high limits for RX Quality test with integer separated by a co...

Page 130: ...NDition LIMit BER IB Class II GSM Mode Test Mode A CONFigure CONDition LIMit BER II real HI CONFigure CONDition LIMit BER II Fast BER GSM Mode Test Mode C CONFigure CONDition LIMit FBER real HI CONFigure CONDition LIMit FBER BER GPRS mode Test Mode B CONFigure CONDition LIMit BERGprs real HI CONFigure CONDition LIMit BERGprs Table 5 14 RX Quality Limit Parameter and Preset Value Parameter RX Level...

Page 131: ...rn the set high limit for BER test with real The range is same as that of the command parameter FER GSM Mode Test Mode A Limit CONFigure CONDition LIMit FER real HI CONFigure CONDition LIMit FER This command sets the high limit for Frame Error Ratio FER test The allowable range is from 0 00 to 99 99 in 0 01 steps At preset this is set to 0 12 This query command returns the set high limit for FER t...

Page 132: ...eal The range is same as that of the command parameter EVM CONFigure CONDition LIMit EVM RMS real HI CONFigure CONDition LIMit EVM RMS CONFigure CONDition LIMit EVM PEAK real HI CONFigure CONDition LIMit EVM PEAK CONFigure CONDition LIMit EVM Ninetyfive real HI CONFigure CONDition LIMit EVM Ninetyfive These commands set high limit for EVM Test The allowable range is from 0 00 to 99 99 in 0 01 step...

Page 133: ...S MODulation This command sets high limit for ORFS Modulation for Radio System that is being selected The allowable range is from 99 9 to 0 0 dB At preset this is set to 50 0 dB ORFS Switching Limit CONFigure CONDition LIMit ORFS Switching int CONFigure CONDition LIMit ORFS Switching This command sets high limit for ORFS Switching for Radio System that is being selected The allowable range is from...

Page 134: ... set to GMSK 50 0 This query command returns modulation type and high limit ORFS Switching Limit Expand CONFigure CONDition LIMit ORFS Switching EXPand GMSK PSK real CONFigure CONDition LIMit ORFS Switching EXPand This command sets high limit for ORFS Switching test for Radio System that is being selected Modulation type PSK is available only when the GSM Mode is EGPRS real is high limit value The...

Page 135: ... is set to GMSK Signaling Pattern CONFigure CONDition SIGNalingpattern int CONFigure CONDition SIGNalingpattern This command sets signaling pattern The allowable range is from 1 to 255 At preset this is set to 1 Power Ramp Template CONFigure CONDition LIMit RAMP MASK PCS NARRow RELaxed CONFigure CONDition LIMit RAMP MASK PCS This command sets template type of Power Ramp measuremnt for PCS1900 The ...

Page 136: ...between a mobile phone and the Tester caused by the RF Input path for radio system of GSM850 GSM900 DCS1800 and PCS1900 respectively The allowable range is from 0 0 to 99 9 dB in 0 1 steps At preset it is set to 0 0 dB This query command returns the loss setting with real value The range of the values is same as that of the command parameter Attenuation Level Setting for Output Signal CONFigure LO...

Page 137: ...om 0 to 3 in 1 steps At preset this is set to 3 This query command returns the Multiband Reporting BA Table Neighbour Cell Channel CONFigure CONDition BA TABLe int enum CONFigure CONDition BA TABLe This command selects the Channel of Neighbor Cell in BA Table NOTE For Signal Generator function attenuation settings for output signal are applied Table 5 15 Neighbour Cell Channel Parameter and Preset...

Page 138: ...CONDition BA TABLe LIST This query command returns the channels of Neighbor Cell from 1 to 16 in BA Table at one time Table 5 16 Neighbour Cells Channel 1 to 16 Parameter and Preset Value RFORmat Parameter PRESET value enum1 enum2 to 16 enum1 enum2 to 16 GSM850 OFF BCCH 128 to 251 OFF 128 to 251 BCCH OFF GSM900 OFF BCCH 955 to 1023 0 to 124 OFF 955 to 1023 0 to 124 BCCH OFF DCS1800 OFF BCCH 512 to...

Page 139: ...r into the HDD or USB memory device FILENAME accepts up to 8 alphanumeric characters COMMENT accepts up to 23 alphanumeric characters Date and Time are automatically given by the Tester FILENAME and COMMENT are double quoted strings Recall File CONFigure FILE RECall string FILENAME This command restores the test setup file specified by FILENAME from the HDD or a USB memory device into the Tester F...

Page 140: ...t to value from 301 to 2147483647 The result of File List or File List Short query command is 0 At preset this is set to 1 This query command returns the set the start number The range of the value is same as that of the command parameter File List Request Number CONFigure FILE LIST REQuest int CONFigure FILE LIST REQuest This command sets the number of the setup files File List and File List Shor...

Page 141: ...o 100 string filename_n 8 letters is the file name of the n th file string date_n 10 letters is the date in yyyy mm dd format of the n th file string time_n 5 letters is the time in hh mm format stored in the n th file string comment_n 23 letters is the comment of the n th file where n ranges from 1 to the last number of the files total in the HDD or a USB memory device Replace File CONFigure FILE...

Page 142: ...o 100 string FILENOn 3 letters is the n th file number ranging from 001 to 100 string FILENAMEn 8 letters is the file name of the n th file File System CONFigure FILE SYSTem GSM WCDMA MULTI CONFigure FILE SYSTem This command selects the file system from MULTI GSM and WCDMA At preset this is set to MULTI This query command returns the set file system with enum ...

Page 143: ...ay CONFigure NETwork GATEway SET1 SET5 IP Address CONFigure NETwork IPaddress string IPADDRESS int CONFigure NETwork IPaddress This command displays the address being specified for the IPADDRESS on the screen int specifies the subnet mask address A value in CIDR format is entered to int Effective setting range for the IPADDRSS is 1 0 0 1 to 223 255 255 255 and the subnet mask address in CIDR forma...

Page 144: ... specified for enum setting in the DEFAULTGATEWAY is unnecessary Executing this command does not reflect the result on the tester yet The result is reflected on the tester as CONFigure NETwork APPLy ADDRess is implemented Query of this command obtains the address of the Default Gateway being set If NONE is selected for the Default Gateway address the value of enum alone is returned Gateway CONFigu...

Page 145: ... enum2 the address is treated as the Host specifying address and functions as the Gateway for the communication directed to one of the Hosts enum2 is used to select which of the Host and Net is to be specified and also used to specify the subnet mask value of the specified subnet when the Net is specified When NONE is selected the address of string1 is treated as the Host address If any value othe...

Page 146: ... When NONE is selected from the enable disable of the Gateway address it returns the value of enum1 alone Table 5 17 Effective Gateway Setting Range Parameters Possible set value Hz enum1 ACT NONE string1 When enum2 NONE 1 0 0 1 223 255 255 255 When enum2 Other than NONE 1 0 0 0 223 255 255 255 enum2 NONE 1 31 In CIDR format string2 1 0 0 1 223 255 255 255 ...

Page 147: ...ial test condition for the Stand by or Measuring screens The query commands return the settings of those controls and parameters BCCH Channel TESTs AUTO BCCH int TESTs AUTO BCCH This command sets the Broadcast Control Channel number BCCH for each radio system set by the Radio System command described on page 5 34 The allowable range and preset values are as follows This query command returns the s...

Page 148: ...Talk test for arbitrary radio system The allowable range and preset values are as follows The preset values of radio system and channel are GSM900 and 1 respectively This query command returns the set channel number of the Traffic Channel for Talk Test with integer The range of the value is the same as that of the command parameter Table 5 19 TCH Allowable Range and Preset Value RFORmat Allowable ...

Page 149: ...7890123456789 This query command returns the set Caller ID with string Screen Mode TESTs AUTO SCReen SIMPlified DETailed VALue TESTs AUTO SCReen This command selects the screen mode The parameter is SIMPlified DETailed or VALue At preset this is set to SIMPlified Query of this command returns the screen mode currently selected in the character stings of the SIMPlified DETailed or VALue Measurement...

Page 150: ...reset values are as follows These six query commands return each set channel number of the Traffic Channel number for the measurement test with integer The range is same as that of the command parameter TESTs AUTO VARiable TCH CHANnel1 EXPand enum int TESTs AUTO VARiable TCH CHANnel1 EXPand TESTs AUTO VARiable TCH CHANnel2 EXPand enum int TESTs AUTO VARiable TCH CHANnel2 EXPand TESTs AUTO VARiable...

Page 151: ...If the parameter is set to NONE or 9999 the measurement test is skipped is shown in the table cell The allowable range are as follows The preset values of the radio system and channel are GSM900 and 1 respectively These six query commands return the radio system of the measurement test with strings and channel number of Traffic Channel with integer The range of the value is the same as that of the...

Page 152: ... 2nd Release bit 7 128 Measurement end with test result bit 8 256 Measurement end without test result Aborted or Time out error occurred The executed step is set to 1 and the others are set to 0 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 TESTs AUTO MEASure SIGNaling STATe EXPand This query command returns the test contents cu...

Page 153: ...rs on page 4 18 Power Ramp Template TESTs AUTO RAMP MASK PCS NARRow RELaxed TESTs AUTO RAMP MASK PCS This command sets template type of Power Ramp measuremnt for PCS1900 The parameter is NARRow or RELaxed At preset this is set to NARRow If RELaxed is set the template is selected same one for DCS1800 This setting is initialized to NARRow at power on IMSI control TESTs AUTO IMSI string TESTs AUTO IM...

Page 154: ...it 1 2 1st Call bit 2 4 Talk bit 3 8 RF Test bit 4 16 1st Release bit 5 32 2nd Call bit 6 64 2nd Release bit 7 128 Measurement aborted Each bit is set to 0 if the test is pass or skipped or each bit is set to 1 if the test is fail If there are no test results all bits are set to 1 the value 255 is returned int 2 contains test results by the total sum of 10 bits as follows bit 0 1 Peak TX Power bit...

Page 155: ...RESults ALL EXPand This query command returns summary of the test results with the integer value of int 1 int 2 and int 3 Each value is separated by a comma int 1 contains test results by sum of the value of 11 bits as follows bit 0 1 Location Update bit 1 2 1st Call bit 2 4 Talk bit 3 8 1st Release bit 4 16 2nd Call bit 5 32 NA bit 6 64 2nd Release bit 7 128 NA bit 8 256 RF Test bit 9 512 NA bit ...

Page 156: ...2 Sensitivity bit 6 64 RX Quality bit 7 128 RX Level bit 8 256 NA bit 9 512 Abort Each bit is set to 0 if the test passed or skipped or each bit is set to 1 if the test failed The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 If there are no test results all bits are set to 1 the value 1023 is returned int 3 contains the system curr...

Page 157: ...e measurement range or 1 if measurement result is out of range or the TX Power is not measured int 2 1 digit contains test results by the total sum of 3 bits as follows bit 0 1 Pass or Fail result for Peak TX Power High bit 1 2 Pass or Fail result for Peak TX Power Medium bit 2 4 Pass or Fail result for Peak TX Power Low Each bit is set to 0 if the test is pass or each bit is set to 1 if the test ...

Page 158: ...se query commands return the Burst Timing measurement result values int 1 int 2 and real 3 for each of the six measurements channels Each value is separated by a comma int 1 1 digit is 0 if measurement result is within the measurement range or 1 if measurement result is out of range or the Burst Timing is not measured int 2 1 digit is the test result for the 0 pass or 1 fail real 3 4 letters is th...

Page 159: ...surement result is within the measurement range or 1 if measurement result is out of range or the Power Ramp is not measured int 2 1 digit is the test result for the 0 pass or 1 fail Power Ramp Graph Zoom TESTs AUTO RESults RAMP1 ZOOM ON OFF 1 0 TESTs AUTO RESults RAMP1 ZOOM TESTs AUTO RESults RAMP2 ZOOM ON OFF 1 0 TESTs AUTO RESults RAMP2 ZOOM TESTs AUTO RESults RAMP3 ZOOM ON OFF 1 0 TESTs AUTO R...

Page 160: ... MARKer TESTs AUTO RESults RAMP3 MARKer TESTs AUTO RESults RAMP4 MARKer TESTs AUTO RESults RAMP5 MARKer TESTs AUTO RESults RAMP6 MARKer These query commands return values at marker position on the Power Ramp graph screen with values int 1 int 2 real 3 and real 4 for each of the six measurement channels Each value is separated by comma int 1 1 digit is 0 if measurement result is within the measurem...

Page 161: ...OINt UP DOWM TESTs AUTO RESults PHASe4 MARKer POINt real TESTs AUTO RESults PHASe4 MARKer POINt TESTs AUTO RESults PHASe5 MARKer POINt UP DOWN TESTs AUTO RESults PHASe5 MARKer POINt real TESTs AUTO RESults PHASe5 MARKer POINt TESTs AUTO RESults PHASe6 MARKer POINt UP DOWN TESTs AUTO RESults PHASe6 MARKer POINt real TESTs AUTO RESults PHASe6 MARKer POINt These commands move the marker UP or DOWN in...

Page 162: ...lts are within the measurement range or 1 if any measurement result is out of range or the Phase Error is not measured int 2 1 digit contains test results by the total sum of 2 bits as follows bit 0 1 Pass or Fail result for RMS Phase Error bit 1 2 Pass or Fail result for Peak Phase Error Each bit is set to 0 if the test is pass or each bit is set to 1 if the test is fail The value in the parenthe...

Page 163: ...graph screen with values int 1 int 2 real 3 and real 4 for each of the six measurement channels Each value is separated by a comma int 1 1 digit is 0 if measurement results are within the measurement range or 1 if value is out of range or the Phase Error is not measured int 2 1 digit is the test result for the 0 pass or 1 fail real 3 up to 6 letters is the marker position ranging from 0 00 to 147 ...

Page 164: ...TO RESults PHASe3 MARKer POINt TESTs AUTO RESults PHASe4 MARKer POINt UP DOWM TESTs AUTO RESults PHASe4 MARKer POINt real TESTs AUTO RESults PHASe4 MARKer POINt TESTs AUTO RESults PHASe5 MARKer POINt UP DOWN TESTs AUTO RESults PHASe5 MARKer POINt real TESTs AUTO RESults PHASe5 MARKer POINt TESTs AUTO RESults PHASe6 MARKer POINt UP DOWN TESTs AUTO RESults PHASe6 MARKer POINt real TESTs AUTO RESults...

Page 165: ...is not measured the value 99 99 is returned real3 is the minimum value dB If measurement result is out of range or measurement result is not measured the value 99 99 is returned Power Ramp Trace Start TESTs AUTO RESults RAMP1 TRACe STARt real TESTs AUTO RESults RAMP1 TRACe STARt TESTs AUTO RESults RAMP2 TRACe STARt real TESTs AUTO RESults RAMP2 TRACe STARt TESTs AUTO RESults RAMP3 TRACe STARt real...

Page 166: ...TESTs AUTO RESults RAMP2 TRACe NUMber int TESTs AUTO RESults RAMP2 TRACe NUMber TESTs AUTO RESults RAMP3 TRACe NUMber int TESTs AUTO RESults RAMP3 TRACe NUMber TESTs AUTO RESults RAMP4 TRACe NUMber int TESTs AUTO RESults RAMP4 TRACe NUMber TESTs AUTO RESults RAMP5 TRACe NUMber int TESTs AUTO RESults RAMP5 TRACe NUMber TESTs AUTO RESults RAMP6 TRACe NUMber int TESTs AUTO RESults RAMP6 TRACe NUMber ...

Page 167: ...step is 0 125 Bits step and the number of data is 1325 The start point is set by the command TESTs AUTO RESults RAMPn The number of data is set by the command TESTs AUTO RESults RAMP1 int1 is 0 if measurement result is within the measurement range or 1 if measurement result is out of range or the Access Probe Power is not measured real2 is the start point of data real3 is the number of step real4 ...

Page 168: ...s RAMP6 MASK LOWer POINts This query command returns the number of lower limit sections in Power Ramp template int is 13 It is a fixed value Power Ramp Mask Upper Points TESTs AUTO RESults RAMP1 MASK UPPer POINts TESTs AUTO RESults RAMP2 MASK UPPer POINts TESTs AUTO RESults RAMP3 MASK UPPer POINts TESTs AUTO RESults RAMP4 MASK UPPer POINts TESTs AUTO RESults RAMP5 MASK UPPer POINts TESTs AUTO RESu...

Page 169: ... value dB of lower limit sections in the Power Ramp template real1 real3 real5 real7 real9 real11 real13 real15 real17 real19 real21 real23 real25 show the point of section end Bits Refer the Table 5 23 real2 real4 real6 real8 real10 real12 real14 real16 real18 real20 real22 real24 real26 show the limit value dB Table 5 23 The Lower Limit Value in GMSK 8PSK Section GMSK 8PSK 1 7 500 22 500 2 4 750...

Page 170: ... value dB of upper limit sections in the Power Ramp template real1 real3 real5 real7 real9 real11 real13 real15 real17 real19 real21 real23 real25 show the point of section end Bits Refer the Table 5 24 real2 real4 real6 real8 real10 real12 real14 real16 real18 real20 real22 real24 real26 show the limit value dB Table 5 24 The Upper Limit Value in GMSK 8PSK Section GMSK 8PSK 1 7 500 22 500 2 4 750...

Page 171: ...est result for the pass 0 or fail 1 real 3 up to 5 letters is the measured Frequency Error data ranging from 99999 to 99999 Hz If measurement result is out of range or the Frequency Error is not measured the value 99999 is returned This command is a command for compatibility with the former and returns measured value by the resolution of a 1Hz unit Since a following EXPand command can return in fi...

Page 172: ...t TESTs AUTO RESults SENSitivity1 TESTs AUTO RESults SENSitivity2 TESTs AUTO RESults SENSitivity3 TESTs AUTO RESults SENSitivity4 TESTs AUTO RESults SENSitivity5 TESTs AUTO RESults SENSitivity6 These query commands return the Sensitivity measurement result values int 1 int 2 real 3 real 4 and real 5 for each of the six measurement channels Each value is separated by a comma int 1 1 digit is 0 if m...

Page 173: ...y1 TESTs AUTO RESults QUALity2 TESTs AUTO RESults QUALity3 TESTs AUTO RESults QUALity4 TESTs AUTO RESults QUALity5 TESTs AUTO RESults QUALity6 These query commands return the RX Quality measurement result values int 1 int 2 and int 3 for each of the six measurement channels Each value is separated by a comma int 1 1 digit is 0 if measurement result is within the measurement range or 1 if measureme...

Page 174: ...r each of the six measurement channels Each value is separated by a comma int 1 1 digit is 0 if measurement result is within the measurement range or 1 if measurement result is out of range or the RX Level is not measured int 2 1 digit is the test result for the 0 pass or 1 fail int 3 2 digits is the measured RX Level factor corresponding to one of the RX Level factors as follows If measurement re...

Page 175: ...0 TESTs AUTO RESults MSINformation DIAL This query command returns the dialed number string up to 20 letters Or this command returns Emergency Call in the case of an emergency call number is dialed At preset this is set to 0 TESTs AUTO RESults MSINformation PCLass This query command returns a 1 digit power class value int At preset this is set to 0 TESTs AUTO RESults MSINformation GVERsion This qu...

Page 176: ... System to be tested The parameter is specified from GSM850 GSM900 DCS1800 and PCS1900 At preset this is set to GSM900 This query command returns the selected Radio System with strings BCCH Channel TESTs MANual BCCH CHANnel int TESTs MANual BCCH CHANnel This command sets the Broadcast Control Channel number BCCH for each radio system set by the Radio System command described above The allowable ra...

Page 177: ...em command described on page 5 118 The allowable range and preset values are as follows The setting of this command and the setting of the BCCH Channel command described on page 5 118 change synchronously This query command returns the set frequency of the Broadcast Control Channel with real The range of the value is same as that of the command parameter Table 5 28 BCCH Frequency Allowable Range a...

Page 178: ...e Traffic Channel number with integer The range of the value is same as that of the command parameter TESTs MANual TCH CHANnel EXPand enum int TESTs MANual TCH CHANnel EXPand This command sets the Traffic Channel number TCH of Talk test for arbitrary radio system The allowable range and preset values are as follows Table 5 29 TCH Channel Allowable Range and Preset Value RFORmat Allowable Range Pre...

Page 179: ...io System command described on page 5 118 The allowable range and preset values are as follows The setting of this command and the setting of the Traffic Channel command described on page 5 120 change synchronously This query command returns the set frequency of the Traffic Channel with real The range of the value is same as that of the command parameter TESTs MANual TCH FREQuency EXPand enum int ...

Page 180: ... with integer The range of the value is the same as that of the command parameter Timing Advance TESTs MANual TADVance int TESTs MANual TADVance This command sets the number of bits for the timing advance value The allowable range is from 0 to 63 bits Power Control Level TESTs MANual PLEVel int TESTs MANual PLEVel This command sets a value of Power Control Level for each radio system set by the Ra...

Page 181: ...e range of the value is same as that of the command parameter Slot Configuration TESTs MANual SCONfigure 1 1 2 1 2 2 3 1 3 2 4 1 TESTs MANual SCONfigure This command selects the slot combination for downlink and uplink respectively on the Stand by screen for the GPRS EGPRS mode in conjunction with the Slot Order Measured setting The combinations of the slot configuration and the slot order measure...

Page 182: ...er of slot to be measured on the Stand by screen for the GPRS EGPRS mode in conjunction with the Slot Configuration setting The combinations of the slot order measured and the slot configuration are as follows Table 5 34 Slot Configuration and Slot Order Measured Slot Configuration Downlink Uplink Slot Order Measured 1 1 2 2 1 3 2 2 2 3 3 1 3 3 2 3 4 4 1 4 NOTE If the mode is set to GPRS EGPRS thi...

Page 183: ...s set to 1 This query command returns the set of the Peak TX Power Burst Timing and Power Ramp test with integer value of 1 or 0 The meaning of the return value is same as that of the command parameter Phase Error Frequency Error EVM Origin Offset Spr Test TESTs MANual PHASe STATe ON OFF 1 0 TESTs MANual PHASe STATe This command sets whether to execute the Phase Error Frequency Error and EVM Origi...

Page 184: ...oopback BER test with integer value of 1 or 0 The meaning of the return value is same as that of the command parameter Averaging TESTs MANual AVERage OFF 2 200 TESTs MANual AVERage This command sets whether to activate the averaging The parameter is OFF or int for the number of averaging times The allowable range of int is from 2 to 200 At preset this is set to OFF This query command returns the s...

Page 185: ... BS Call AMR test step Up to 20 digit arbitrary number 0 to 9 and symbol can be set This is not initialized by PRESET execution with the Starting Condition softkey This query command returns the set Caller ID with string Caller ID Sending TESTs MANual CALLer ID SEND ON OFF 1 0 TESTs MANual CALLer ID SEND This command sets the Caller ID on the Stand by screen string Sets dialing number at BS Call A...

Page 186: ... Ramp Template TESTs MANual TXP MASK PCS NARRow RELaxed TESTs MANual TXP MASK PCS This command sets template type of Power Ramp measuremnt for PCS1900 The parameter is NARRow or RELaxed At preset this is set to NARRow If RELaxed is set the template is selected same one for DCS1800 This setting is initialized to NARRow at power on IMSI control TESTs MANual IMSI string TESTs MANual IMSI This command...

Page 187: ...e RELaxed is same as one of DCS1800 This query command returns the time mask setting with string value of NARR or REL This command is available for GSM only Command Reference for Signaling Screens These commands are used to set the controls and parameters associated with an initial test condition Location Update TESTs MANual LOCupdate This command executes a Location update procedure to the mobile...

Page 188: ... enabled in the standby status GSM and GPRS are available when the G00 option is installed and EGPRS is available when the G00 and G03 options are installed Likewise the W00 and W06 options are required for HSDPA the C00 and C01 options are required for MC1 and the C00 C01 and C02 options are required for EVDO Query of this command obtains the currently set mode in the character string Signaling S...

Page 189: ...rns test content and result currently being executed with integer value in int 1 and int 2 Each value is separated by a comma int 1 contains test contents by sum of the value of 10 bits as follows bit 0 1 MS Call BS Call bit 1 2 Talk RF Test bit 2 4 MS Release BS Release bit 3 8 Time out error bit 4 16 End bit 5 32 Location Update bit 6 64 Busy bit 7 128 SMSCB bit 8 256 SMSMO bit 9 512 SMSMT The s...

Page 190: ...follows bit 0 1 MS Call BS Call bit 1 2 Talk RF Test bit 2 4 MS Release BS Release bit 3 8 Time out error currently unused bit 4 16 End Stand by status bit 5 32 Location Update bit 6 64 Busy bit 7 128 SMS CB bit 8 256 SMS MO bit 9 512 SMS MT bit 10 1024 NA The step in execution is set to 1 and the others are set to 0 The value in the parentheses is decimal value for each bit Refer to Setting and Q...

Page 191: ... others are set to 0 The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 TESTs MANual SIGNaling STATe EXTension This query command returns test content and result currently being executed with integer value of int 1 and int 2 Each value is separated by a comma int 1 contains test contents currently being executed in GPRS EGPRS mode Th...

Page 192: ...ype currently being executed with integer value of int 1 and int 2 Each value is separated by a comma int 1 contains test contents currently being executed in GPRS EGPRS mode The following 7 bit values are returned bit 0 1 Attach bit 1 2 Attached bit 2 4 Connected bit 3 8 Timeout Error bit 4 16 NA bit 5 32 NA bit 6 64 Processing The step in execution is set to 1 and the others are set to 0 The val...

Page 193: ... B SRB TESTs MANual TESTLoopmode EGPRS This command sets the Test Loop mode The allowable range is as follows Coding Scheme GPRS mode TESTs MANual CSCHeme int TESTs MANual CSCHeme This command sets GPRS Coding Scheme The allowable range is 1 to 4 At preset this is set to 1 Table 5 36 Test Loop Mode Allowable Range and Preset Value Mode Allowable Range Preset Value GSM A C A GPRS ACK A B ACK EPGRS ...

Page 194: ...s sum of the value of 7 bits as follows bit 0 1 Location Update bit 1 2 MS Call bit 2 4 MS Release bit 3 8 BS Call bit 4 16 BS Release bit 5 32 Connection bit 6 64 Handover Each bit is set to 0 if the test is pass or each bit is set to 1 if the test is fail The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 If there are no test resul...

Page 195: ... 0 1 Location Update bit 1 2 MS Call bit 2 4 MS Release bit 3 8 BS Call bit 4 16 NA bit 5 32 BS Release bit 6 64 Connection bit 7 128 NA bit 8 256 Handover Each bit is set to 0 if the test passed or each bit is set to 1 if the test failed The value in the parentheses is decimal value for each bit Refer to Setting and Querying the Registers on page 4 18 If there are no test results all bits are set...

Page 196: ... command returns the test contents currently being executed and system type with integer value of int 1 and int 2 Each value is separated by a comma int 1 contains signaling result of manual test by sum of the value of 3 bits ranging from 0 to 7 as follows This query command returns test result with int by sum of the value of 3 bits as follow bit 0 1 Attach bit 1 2 Attached bit 2 4 Connect Each bi...

Page 197: ...ers At preset this is set to 0 TESTs MANual RESults MSINformation PCLass This query command returns a 1 digit power class value int At preset this is set to 0 TESTs MANual RESults MSINformation GVERsion This query command returns the 1 digit version number int of GSM mobile phone under test At preset this is set to 0 TESTs MANual RESults MSINformation QUALity This query command returns a value of ...

Page 198: ...ed the value 63 is returned Multislot Class TESTs MANual RESults MSINformation MULTislotclas s This query command returns the value of Multislot class int 1 is for GPRS int 2 is for EGPRS In the GPRS mode int 2 is set to 0 RF Power Capability TESTs MANual RESults MSINformation RFPowercapabi lity This query command returns the value of RF Power From int1 to int8 in sequence the value of GMSK GSM850...

Page 199: ...rement TESTs MANual RESults BTIMing This query command returns the Burst Timing measurement result values int 1 int 2 and real 3 Each value is separated by a comma int 1 1 digit is 0 if measurement result is within the measurement range or 1 if measurement result is out of range or the Burst Timing is not measured int 2 1 digit is the test result for the 0 pass or 1 fail real 3 4 letters is the me...

Page 200: ...ail results for EVM 95 real 3 real 4 and real5 4 letters is the measured data of RMS PEAK and 95 of EVM respectively The data is ranging from 0 00 to 100 00 If measurement result is out of range or the EVM is not measured the value 99 99 is returned Phase Error Measurement TESTs MANual RESults PHASe This query command returns the Phase Error measurement result values int 1 int 2 real 3 and real 4 ...

Page 201: ...s out of range or the Frequency Error is not measured int 2 1 digit is the test result for the 0 pass or 1 fail int 3 up to 6 letters is the measured Frequency Error data ranging from 99999 to 99999 in Hz If measurement result is out of measurement range or the Frequency Error is not measured the value 99999 is returned This command is a command for compatibility with the former and returns measur...

Page 202: ...t 2 1 digit is the test result for the 0 pass or 1 fail int 3 1 digit is the measured RX Quality factor ranging from 0 0 2 to 7 12 8 If measurement result is out of range or the RX Quality is not measured the value 7 is returned Actual Timing Advance TESTs MANual RESults ACTAdvance This query command returns the actual Timing Advance with integer value ranging from 0 to 63 in bits Origin Offset Sp...

Page 203: ... the 0 pass or 1 fail real 3 returns Marker position bits real 4 up to 6 letters is the measured EVM Marker data ranging from 0 00 to 100 00 EVM Marker Point TESTs MANual RESults EVM MARKer POINt UP Down TESTs MANual RESults EVM MARKer POINt real This command moves the marker position Up or Down in steps or by real bits ranging from 0 00 to 423 00 in bits NOTE This command is valid when the Modula...

Page 204: ...he selected zooming function on the Power Ramp graph screen with integer value of 1 or 0 The meaning of the return value is same as that of the command parameter Power Ramp Marker Measurement TESTs MANual RESults RAMP MARKer This query command returns values at marker position on the Power Ramp graph screen with values int 1 int 2 real 3 and real 4 Each value is separated by a comma int 1 1 digit ...

Page 205: ...turned Power Ramp Marker Position Control TESTs MANual TXAMplitude RESults MARKer POINt UP DOWN TESTs MANual TXAMplitude RESults MARKer POINt real TESTs MANual TXAMplitude RESults MARKer POINt GSM GPRS EGPRS MCS1 4 This command moves the marker position UP or DOWN in steps or by real in bits ranging from 9 25 to 156 25 when the zoom function is set to Off or from 8 00 to 2 00 and 145 00 to 155 00 ...

Page 206: ... value 99 9 is returned real3 is minimum value dB If measurement result is out of range or the Access Probe Power is not measured the value 99 9 is returned Power Ramp Trace Start TESTs MANual RESults RAMP TRACe STARt real TESTs MANual RESults RAMP TRACe STARt This command sets the start point of trace data in Power Ramp for the query command The range of a value is from 9 250 to 156 250 Bits in G...

Page 207: ... value to TCH1 to TCH6 Manual Test and TX Analyzer Power Ramp Trace TESTs MANual RESults RAMP TRACe This query command returns a value of the trace data in Power Ramp The range of a value is from 9 250 to 156 250 Bits in GMSK The step is 0 125 Bits step and the number of data is 1325 in GMSK The range of a value is from 27 750 to 468 750 Bits in 8PSK The step is 0 375 Bits step and the number of d...

Page 208: ...RAMP MASK UPPer POINTs This query command returns the number of upper limit sections in the Power Ramp template int is 13 It is a fixed value Power Ramp Mask Lower TESTs MANual RESults RAMP MASK LOWer This query command returns the point of section end Bits and the limit value dB of lower limit sections in the Power Ramp template real1 real3 real5 real7 real9 real11 real13 real15 real17 real19 rea...

Page 209: ...9 real11 real13 real15 real17 real19 real21 real23 real25 show the point of section end Bits Refer the Table 5 38 real2 real4 real6 real8 real10 real12 real14 real16 real18 real20 real22 real24 real26 show the limit value dB Table 5 37 The Lower Limit Value in GMSK 8PSK Section GMSK 8PSK 1 7 500 22 500 2 4 750 14 250 3 2 625 7 875 4 0 000 0 000 5 0 500 1 500 6 1 000 3 000 7 146 000 438 000 8 146 5...

Page 210: ...ce Table 5 38 The Upper Limit Value in GMSK 8PSK Section GMSK 8PSK 1 7 500 22 500 2 4 750 14 250 3 2 625 7 875 4 0 000 0 000 5 0 500 1 500 6 1 000 3 000 7 146 000 438 000 8 146 500 439 500 9 147 000 441 000 10 149 750 449 250 11 151 875 455 625 12 154 625 463 875 13 156 250 468 750 ...

Page 211: ...t 1 1 digit is 0 if measurement result is within the measurement range or 1 if measurement result is out of range or the Phase Error is not measured int 2 1 digit is the test result for the 0 pass or 1 fail real 3 up to 6 letters is the marker position ranging from 0 00 to 147 00 in bits real 4 up to 5 letters is the measured Phase error at marker position If measurement result is out of range or ...

Page 212: ...ment TESTs MANual RESults LEVel This query command returns the RX Level measurement result values int 1 int 2 and int 3 Each value is separated by a comma int 1 1 digit is 0 if measurement result is within the measurement range or 1 if measurement result is out of range or the RX Level is not measured int 2 1 digit is the test result for the 0 pass or 1 fail NOTE If the mode is set to GPRS or EGPR...

Page 213: ... 0 to 50 0 dBm in 0 1 steps At preset this is set to 102 0 dBm for GSM850 GSM900 and PCS1900 or 100 0 dBm for DCS1800 This query command returns the set amplitude BS Level for Sensitivity BER tests with real ranging from 110 0 to 50 0 in dBm Sensitivity BER and FER Measurement GSM mode Testloop Mode A TESTs MANual RESults SENSitivity This query command returns the Sensitivity measurement result va...

Page 214: ...e Sensitivity is not measured the value 99 99 is returned Sensitivity BLER Measurement GPRS EGPRS mode TESTs MANual RESults SENSitivity This query command returns the Sensitivity measurement result values int 1 int 2 real 3 and real 4 when GSM mode is selected and the Test Loop Mode is set to A Each value is separated by a comma int 1 1digit is fixed to 1 int 2 1digit is the test result for the 0 ...

Page 215: ...measurement results are within the measurement range or 1 if any measurement result is out of range or the BER is not measured int 2 1digit is the test result for the 0 pass or 1 fail real 3 is the measured result of the BER data ranging from 0 00 to 100 00 in If measurement result is out of range or the BER is not measured the value 99 99 is returned Sensitivity Test Frames GSM Mode Test Loop A T...

Page 216: ... SRB This command sets the number of test frames for error ration test The allowable range is from 1 to 13000 frames in 1 step At preset this is set to 10 frames Puncturing Scheme TESTs MANual PUNCturing P1 P2 P3 TESTs MANual PUNCturing This command sets the Puncturing Scheme in EGPRS mode At preset this is set to P1 P1 and P2 are valid for all modulation and Coding Scheme P3 is valid only when th...

Page 217: ... The allowable range is from 1 to 200 At preset this is set to 1 This query command returns the set EVM measurement count with integer ranging from 1 to 200 Output RF Spectrum ORFS ORFS Modulation TESTs MANual ORFS MOD STATe ON OFF 0 1 TESTs MANual ORFS MOD STATe This command sets whether to execute each measurement item of the ORFS Modulation The parameter is ON 1 or OFF 0 At preset this is set t...

Page 218: ...ing from 1 to 200 At preset this is set to 1 ORFS Modulation Measurement TESTs MANual RESults ORFS MOD This query command returns the ORFS Modulation measurement result values int 1 int 2 real 3 and real 4 Each value is separated by a comma int 1 1 digit is 0 if measurement results are within the measurement range or 1 if any measurement result is out of range or the ORFS Modulation is not measure...

Page 219: ...re within the measurement range or 1 if any measurement result is out of range or the ORFS Switching is not measured int 2 1digit is the test result for the 0 pass or 1 fail real 3 is the Lower value and real 4 is the Upper value of the measurement results If the measurement result is out of range or the ORFS Switching is not measured the value 99 99 is returned Ref Power TESTs MANual RESults ORFS...

Page 220: ...s 0 if measurement results are within the measurement range or 1 if any measurement result is out of range or the Spectrum monitor is not measured The definitions and ranges of string 2 10 digits real 3 5 letters real 4 7 letters and real 5 5 letters are shown in the table below If any measurement result is out of range or the Spectrum Monitor is not measured the values 9999999999 for string 2 99 ...

Page 221: ...t results are within the measurement range or 1 if any measurement result is out of range or the Spectrum monitor is not measured The definitions and ranges of string 2 10 digits real 3 5 letters real 4 5 letters and real 5 5 letters are shown in the table below If any measurement result is out of range or the Spectrum monitor is not measured the values 9999999999 for string 2 and 99 9 for real 3 ...

Page 222: ...uery command returns the set CB sent text message with strings TESTs MANual SMSCbmt BIN int 1 int 2 int 3 string 4 TESTs MANual SMSCbmt BIN This command sets a MT sent binary message to the MS for the SMS CB MT on the Stand by screen int 1 sets the Coding Scheme for CB int 2 sets the Coding Scheme for MT int 3 sets the data size of string 4 string 4 sets the sent message an hexadecimal string pack...

Page 223: ...ASC and BIN ASC indicates text data ASCII and BIN indicates binary data int 2 indicates the value of the Coding Scheme int 3 indicates the data length ASCII data Maximum 322 bytes Binary data Maximum 140 bytes Represented by 280 characters in the hexadecimal format string 4 indicates the received message SMS CB TESTs MANual SMSCb This command starts SMS CB SMS MT TESTs MANual SMSMt This command st...

Page 224: ...cted Radio System with strings RFCH TXANalyzer RFCH CHANnel int TXANalyzer RFCH CHANnel This command sets the channel number to be tested for each radio system set by the Radio System command described above The allowable range and preset values are as follows The setting of this command and the setting of the Frequency command described on page 5 167 change synchronously This query command return...

Page 225: ... setting of this command and the setting of the RFCH command described on page 5 166 change synchronously This query command returns the set frequency to be tested with real The range of the value is same as that of the command parameter Table 5 43 RFCH Frequency Allowable Range and Preset Value RFORmat Allowable Range Hz Preset Value Hz GSM850 824200000 to 848800000 836200000 GSM900 876200000 to ...

Page 226: ...dBm in 0 1 steps At preset this is set to 50 0 dBm This query command returns the set amplitude of output signal by real ranging from 110 0 to 20 0 dBm MS Signal TXANalyzer SIGNal BURST CW TXANalyzer SIGNal This command selects a signaling type from the mobile phone for analysis The parameter is BURST or CW At preset this is set to BURST This query command returns the selected signal type with str...

Page 227: ... Power Burst Timing and Power Ramp test The parameter is ON 1 or OFF 0 At preset this is set to 1 This query command returns the set of the Peak TX Power test with integer value of 1 or 0 The meaning of the return value is same as that of the command parameter Phase Error Frequency Error EVM Origin Offset Spr Mode TXANalyzer PHASe STATe ON OFF 1 0 TXANalyzer PHASe STATe This command sets whether t...

Page 228: ... PN15 ALL0 ALL1 AM PSK9 PSK15 TXANalyzer MODulation This command sets a type of Modulation for the Signal Generator The parameter for GMSK is BCCH PN9 PN15 ALL0 and ALL1 while the parameter for 8 PSK is PSK9 and PSK15 At preset this is set to BCCH Demodulation TXANalyzer DEMODulation GMSK PSK TXANalyzer DEMODulation This command sets demodulation of the Tester The parameter is GMSK or PSK 8 PSK At...

Page 229: ...TXANalyzer EVMMeascount This command sets the value of EVM Meas Count The parameter is ranging from 1 to 200 At preset this is set to 1 Change System TXANalyzer SYSTem GSM WCDMA CDMA2000 TXANalyzer SYSTem This command causes switching to the specified system GSM W CDMA and CDMA2000 It is enabled in the standby status Query of this command obtains the specified system in the character string NOTE T...

Page 230: ...w If RELaxed is set the template is selected same one for DCS1800 This setting is initialized to NARRow at power on Peak TX Power Measurement TXANalyzer RESults TXPower This query command returns the Peak TX Power measurement result values int 1 int 2 and real 3 Each value is separated by a comma int 1 1 digit is 0 if measurement result is within the measurement range or 1 if measurement result is...

Page 231: ...oming function on the Power Ramp graph screen The parameter is ON 1 or OFF 0 If the parameter is set to ON the rising and trailing edges are expanded At preset this is set to 0 This query command returns the selected zooming function on the Power Ramp graph screen with integer value of 1 or 0 The meaning of the return value is same as that of the command parameter Power Ramp Marker Measurement TXA...

Page 232: ...rs is the measured power level at the marker position If measurement result is out of range or the Power Ramp is not measured the value 99 9 is returned Power Ramp Marker Position Control TXANalyzer RESults RAMP MARKer POINt UP DOWM TXANalyzer RESults RAMP MARKer POINt real TXANalyzer RESults RAMP MARKer POINt GSM GPRS EGPRS MCS1 4 This command moves the marker position UP or DOWN in steps or by r...

Page 233: ...e value 99 9 is returned real3 is minimum value dB If measurement result is out of range or the Access Probe Power is not measured the value 99 9 is returned Power Ramp Trace Start TXANalyzer RESults RAMP TRACe STARt real TXANalyzer RESults RAMP TRACe STARt This command sets the start point of trace data in Power Ramp for the query command The range of a value is from 9 250 to 156 250 Bits in GMSK...

Page 234: ...n value to TCH1 to TCH6 Manual Test and TX Analyzer Power Ramp Trace TXANalyzer RESults RAMP TRACe This query command returns a value of the trace data in Power Ramp The range of a value is from 9 250 to 156 250 Bits in GMSK The step is 0 125 Bits step and the number of data is 1325 in GMSK The range of a value is from 27 750 to 468 750 Bits in 8PSK The step is 0 375 Bits step and the number of da...

Page 235: ...AMP MASK UPPer POINTs This query command returns the number of upper limit sections in the Power Ramp template int is 13 It is a fixed value Power Ramp Mask Lower TXANalyzer RESults RAMP MASK LOWer This query command returns the point of section end Bits and the limit value dB of lower limit sections in the Power Ramp template real1 real3 real5 real7 real9 real11 real13 real15 real17 real19 real21...

Page 236: ... real11 real13 real15 real17 real19 real21 real23 real25 show the point of section end Bits Refer the Table 5 46 real2 real4 real6 real8 real10 real12 real14 real16 real18 real20 real22 real24 real26 show the limit value dB Table 5 45 The Lower Limit Value in GMSK 8PSK Section GMSK 8PSK 1 7 500 22 500 2 4 750 14 250 3 2 625 7 875 4 0 000 0 000 5 0 500 1 500 6 1 000 3 000 7 146 000 438 000 8 146 50...

Page 237: ...79 Table 5 46 The Upper Limit Value in GMSK 8PSK Section GMSK 8PSK 1 7 500 22 500 2 4 750 14 250 3 2 625 7 875 4 0 000 0 000 5 0 500 1 500 6 1 000 3 000 7 146 000 438 000 8 146 500 439 500 9 147 000 441 000 10 149 750 449 250 11 151 875 455 625 12 154 625 463 875 13 156 250 468 750 ...

Page 238: ...he measurement range or 1 if measurement result is out of range or the Phase Error is not measured int 2 1 digit contains test results by sum of values of 2 bits as follows bit 0 1 Pass or Fail result for RMS Phase Error bit 1 2 Pass or Fail result for Peak Phase Error Each bit is set to 0 if the test is pass or each bit is set to 1 if the test is fail The value in the parentheses is decimal value...

Page 239: ...sured the value 99999 is returned This command is a command for compatibility with the former and returns measured value by the resolution of a 1 Hz unit Since a following EXPand command can return in finer resolution and it is recommendation to use it TXANalyzer RESults FREQuency EXPand This query command returns the Frequency Error measurement result values int 1 int 2 and real 3 Each value is s...

Page 240: ...ass or 1 fail real 3 up to 6 letters is the marker position ranging from 0 00 to 147 00 in bits real 4 up to 5 letters is the measured Phase Error at marker position If measurement result is out of range or the Phase Error is not measured the value 99 9 is returned Phase Error Marker Position Control TXANalyzer RESults PHASe MARKer POINt UP DOWM TXANalyzer RESults PHASe MARKer POINt real TXANalyze...

Page 241: ...ns the measurement result value of RMS Peak and 95 respectively When measurement result is out of range or the EVM was not measured the value 99 99 is returned EVM Marker TXANalyzer RESults EVM MARKer This command returns the EVM Marker value int1 int2 real3 and real4 int 1 1 digit is 0 if measurement result is within the measurement range or 1 if measurement result is out of range or the EVM Mark...

Page 242: ... 3 Each value is separated by a comma int 1 1 digit is 0 if measurement results are within the measurement range or 1 if any measurement result is out of range or the ORFS Switching is not measured int 2 1digit is the test result for the 0 pass or 1 fail real 3 returns the measurement result value of Origin Offset If the measurement result is out of range or the Origin Offset is not measured the v...

Page 243: ... to 1 ORFS Switching TXANalyzer ORFS SW STATe ON OFF 0 1 TXANalyzer ORFS SW STATe This command sets whether to execute each measurement item of the ORFS Switching The parameter is ON 1 or OFF 0 At preset this is set to 1 ORFS Measurement Count TXANalyzer ORFSCount int TXANalyzer ORFSCount This command sets whether to execute each measurement item of the ORFS Measurement count for EGPRS mode The pa...

Page 244: ...ANalyzer RESults ORFS SW This query command returns the ORFS Switching measurement result values int 1 int 2 real 1 and real 2 Each value is separated by a comma int 1 1 digit is 0 if measurement results are within the measurement range or 1 if any measurement result is out of range or the ORFS Switching is not measured int 2 1digit is the test result for the 0 pass or 1 fail real 1 is the Lower v...

Page 245: ... command returns the selected frequency bandwidth with strings The meaning of the return value is same as that of the command parameter Resolution Bandwidth TXANalyzer SMONitor RBWidth 10K 30K TXANalyzer SMONitor RBWidth This command selects a value of RBW Resolution Bandwidth The parameter is 10K for 10 kHz or 30K for 30 kHz This is set to 30K This query command returns the selected RBW with stri...

Page 246: ...1 if any measurement result is out of range or the Spectrum Monitor is not measured The definitions and ranges of int 2 10 digits real 3 5 digits real 4 5 letters real 5 5 letters and real 6 5 letters are shown in the table below If any measurement result out of range or the Spectrum Monitor is not measured the values 9999999999 for int 2 and 99 9 for real 3 real 4 real 5 5 letters and real 6 are ...

Page 247: ...nt 2 99 9 for real 3 and real 5 and 999999 for real 4 are returned Marker Position Control TXANalyzer RESults SMONitor MARKer POINt UP DOWM TXANalyzer RESults SMONitor MARKer POINt int TXANalyzer RESults SMONitor MARKer POINt This command moves the marker UP or DOWN in steps or by a numeric value real The allowable range is from 0 to 400000 Hz for the 0 to 400 kHz span or from 100000 to 100000 Hz ...

Page 248: ...s a Radio System to be tested The parameter is GSM850 GSM900 DCS1800 or PCS1900 At preset this is set to GSM900 This query command returns the selected Radio System with strings RFCH RFGenerator CHANnel int RFGenerator CHANnel This command sets the channel number for each radio system set by the Radio System command described above The allowable range and preset values are as follows Table 5 49 RF...

Page 249: ... the RFCH command described on page 5 190 change synchronously This query command returns the frequency with real The range of the value is same as that of the command parameter Amplitude RFGenerator AMPLitude int RFGenerator AMPLitude This command sets the output amplitude of RF Level The allowable range is from 110 0 to 20 0 dBm in 0 1 steps At preset this is set to 50 0 dBm This query command r...

Page 250: ...hat of the command parameter Modulation RFGenerator MODulation OFF BCCH PN9 PN15 ALL0 ALL1 AM PSK9 PSK15 RFGenerator MODulation This command selects a type of Modulation The parameter is OFF BCCH PN9 PN15 ALL0 ALL1 AM PSK9 and PSK15 At preset this is set to OFF GSMK If OFF is selected the output signal is a continuous wave CW GMSK BCCH GMSK modulation with BCCH data GMSK PN9 GMSK modulation with P...

Page 251: ... return value is same as that of the command parameter RF Signal Output Mode RFGenerator RFOUtput ON OFF 1 0 RFGenerator RFOUtput This command selects RF Signal Output status The parameter is ON 1 or OFF 0 At preset this is set to 0 Change System RFGenerator SYSTem GSM WCDMA CDMA2000 RFGenerator SYSTem This command causes switching to the specified system GSM W CDMA and CDMA2000 Query of this comm...

Page 252: ...ogramming Manual 5 Programming Command Reference HCOPy Subsystem The HCOPy commands are used to control the printing function HCOPy Subsystem Command Reference Print Screen Image HCOPy SDUMp This command executes to print a screen image ...

Page 253: ...ns to the normal operation This command is not identical to the panel key lock on the Configuration screen See Panel Key Control on page 5 33 This query command returns the selected lock function with integer of 1 or 0 The meaning of the return value is same as that of the command parameter Softkey Memory SYSTem MEMory AMPLitude real 1 real 2 real 3 real 4 SYSTem MEMory AMPLitude SYSTem MEMory CHA...

Page 254: ... SYSTem ERRor This query command returns error numbers and error messages by values int 1 and string 2 Refer to Table 4 6 for the listings of the error messages Menu Screen SYSTem RBT This command returns to the Top Menu Screen It is effective when the response of the Display query command is INIT ...

Page 255: ...em and the trigger sequence state returns to idle Trigger Immediately TRIGger IMMediate This command immediately starts a measurement When measurement is completed the Tester s state becomes idle Trigger Mode TRIGger MODE SINGle CONTinuous TRIGger MODE This command selects the trigger mode to either a single or continuous repetitive measurement The parameter is SINGle or CONTinuous At preset this ...

Page 256: ...5 198 N9360A Multi UE Tester GSM Programming Manual 5 Programming Command Reference THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Page 257: ...ion Screen 6 7 Automatic Test Screens 6 20 Manual Test Screens 6 28 TX Analyzer Screens 6 36 Signal Generator Screen 6 41 Print Screen Function 6 42 System Control Function 6 42 Trigger Function 6 43 This chapter contains summary tables for correlating the screens softkeys test parameters and test items with their corresponding syntax for control the Tester ...

Page 258: ...e 6 1 IEEE Common Command Summary Item Command Event Status Register Query ESR Identification Query IDN Reset the Tester RST Operation Complete OPC OPC Clear Status CLS Standard Event Status Enable ESE int ESE Status Byte Register Query STB Instrument Option Query OPT Selftest Result Query TST Table 6 2 Top Menu Command Summary Item Command System Error SYST ERR Lock System Panel SYST KLOC ON OFF ...

Page 259: ...de INIT MOD FUNC Printer Control CONF PRIN PMG800 USBMemory CONF PRIN Beeper Control CONF BEEP ON OFF 1 0 CONF BEEP 10 MHz Reference Oscillator CONF ROSC INT EXT CONF ROSC Date Entry CONF DATE int YYYY int MM int DD CONF DATE Time Entry CONF TIME int HH int MM CONF TIME Autoboot CONF AUTOB none GSM WCDMA CDMA2000 int CONF AUTOB RF Revision CONF REV RF Update Type UPDA TYPE USB HDD SERVER UPDA TYPE...

Page 260: ...nction Mode Firmware List UPDA FIRM LIST FUNC Update G00 Firmware List UPDA FIRM LIST G00 Update W00 Firmware List UPDA FIRM LIST W00 Update System List UPDA FIRM LIST SYS Top Menu Firmware Revision UPDA FIRM REV MENU Function Mode Firmware Revision UPDA FIRM REV FUNC G00 Firmware Revision UPDA FIRM REV G00 W00 Firmware Revision UPDA FIRM REV W00 Update Flash UPDA FLAS TRIG MC1X 1XEVDO Update MC 1...

Page 261: ... PHAS Sensitivity RX Quality RX Level DISP AUTO SENS Configuration Screens System Configuration DISP CONF Test Condition DISP CONF COND Test Condition Loss Screen DISP CONF COND LOSS Test Condition Limit Screen DISP CONF COND LIM Test Sequence DISP CONF SEQ File Management DISP CONF FILE Network Setting DISP CONF NET Configuration Screen BA Table Test Condition BA Screen DISP CONF COND BA Multiban...

Page 262: ...DISP MAN SMS Output RF Spectrum ORFS DISP MAN ORFS TX Analyzer Screens Stand by DISP TXAN STBY Peak TX Power Burst Timing Power Ramp DISP TXAN TPOW Phase Error Frequency Error DISP TXAN PHAS Spectrum Monitor DISP TXAN SMON Output RF Spectrum ORFS DISPl TXAN ORFS Signal Generator Screen RF Signal Generator DISP RFG Table 6 3 DISPlay Subsystem Command Summary Item Command Table 6 4 INITialsoftkey Su...

Page 263: ...d to set the reference signal oscillator source date and time beeper RF attenuation firmware update and so forth which are fundamentally required to operate the Tester Table 6 5 CONFigure Subsystem Command Summary Item Command Beeper Control CONF BEEP ON OFF 1 0 CONF BEEP 10 MHz Reference Oscillator CONF ROSC Date CONF DATE int YYYY int MM int DD CONF DATE Time CONF TIME int HH int MM CONF TIME Pa...

Page 264: ...SEQuence Command Summary Item Command Radio System CONF SEQ RFOR W CDMA GSM850 GSM900 DCS1800 PCS1900 CDMA2000MC1X CDMA2000EVDO OFF CONF SEQ RFOR Sequence Number CONF SEQ NO 1 2 CONF SEQ NO BCCH Channel CONF SEQ BCCH CHAN int CONF SEQ BCCH CHAN Talk Test TCH Channel CONF SEQ TCH CHAN int CONF SEQ TCH CHAN CONF SEQ TCH CHAN EXP GSM850 GSM900 DCS1800 PCS1900 int CONF SEQ TCH CHAN EXP BCCH Frequency ...

Page 265: ...EQ VAR TCH CHAN6 CONF SEQ VAR TCH CHAN1 EXP GSM850 GSM900 DCS1800 PCS1900 int CONF SEQ VAR TCH CHAN1 EXP CONF SEQ VAR TCH CHAN2 EXP GSM850 GSM900 DCS1800 PCS1900 int CONF SEQ VAR TCH CHAN2 EXP CONF SEQ VAR TCH CHAN3 EXP GSM850 GSM900 DCS1800 PCS1900 int CONF SEQ VAR TCH CHAN3 EXP CONF SEQ VAR TCH CHAN4 EXP GSM850 GSM900 DCS1800 PCS1900 int CONF SEQ VAR TCH CHAN4 EXP CONF SEQ VAR TCH CHAN5 EXP GSM8...

Page 266: ...amp Test CONF SEQ RAMP int CONF SEQ RAMP Phase Error Test RMS CONF SEQ PHAS RMS int CONF SEQ PHAS RMS Phase Error Test Peak CONF SEQ PHAS PEAK int CONF SEQ PHAS PEAK Frequency Error Test CONF SEQ FREQ int CONF SEQ FREQ Sensitivity Test BER CONF SEQ SENS BER int CONF SEQ SENS BER Sensitivity Test FER CONF SEQ SENS FER int CONF SEQ SENS FER RX Quality Test CONF SEQ QUAL int CONF SEQ QUAL RX Level Te...

Page 267: ...N2 real 1 real 2 real 3 real 4 CONF SEQ LOSS RFIN CHAN2 CONF SEQ LOSS RFIN CHAN3 real 1 real 2 real 3 real 4 CONF SEQ LOSS RFIN CHAN3 CONF SEQ LOSS RFIN CHAN4 real 1 real 2 real 3 real 4 CONF SEQ LOSS RFIN CHAN4 CONF SEQ LOSS RFIN CHAN5 real 1 real 2 real 3 real 4 CONF SEQ LOSS RFIN CHAN5 CONF SEQ LOSS RFIN CHAN6 real 1 real 2 real 3 real 4 CONF SEQ LOSS RFIN CHAN6 Table 6 6 SEQuence Command Summa...

Page 268: ...l 4 CONF SEQ LOSS RFOUT CHAN5 CONF SEQ LOSS RFOUT CHAN6 real 1 real 2 real 3 real 4 CONF SEQ LOSS RFOUT CHAN6 Location Update CONF SEQ SIGN LOCU OFF LU1 LU2 CONF SEQ SIGN LOCU 1st Call Type CONF SEQ SIGN CALL1 TYPE MS BS CONF SEQ SIGN CALL1 TYPE 1st Call Test CONF SEQ SIGN CALL1 ON OFF 1 0 CONF SEQ SIGN CALL1 1st Release Type CONF SEQ SIGN REL1 TYPE MS BS HO CONF SEQ SIGN REL1 TYPE Talk Test CONF ...

Page 269: ... RFOU AUTO ON CONF SEQ RFOU 3GPP System CONF SEQ 3GPP int CONF SEQ 3GPP Table 6 6 SEQuence Command Summary Item Command Table 6 7 CONDition Command Summary Item Command Current System CONF COND CUR GSM WCDMA CDMA2000 CONF COND CUR Mode CONF COND MODE STD GPRS EGPRS CONF COND MODE Radio System CONF COND RFOR GSM850 GSM900 DCS1800 PSC1900 CONF COND RFOR Network Configuration CONF COND NETW MCC int C...

Page 270: ...IX PN9 PN15 CONF COND DATA Averaging CONF COND AVER OFF int CONF COND AVER BS Level CONF COND AMPL real CONF COND AMPL BER BS Level CONF COND SENS LEV real CONF COND SENS LEV BER Frames CONF COND SENS FRAM int CONF COND SENS FRAM CON COND SENS FRAM BERF int CON COND SENS FRAM BERF CON COND SENS FRAM BERG int CON COND SENS FRAM BERG CON COND SENS FRAM SRB int CON COND SENS FRAM SRB BLER CONF COND S...

Page 271: ...ancy CONF COND INCR ON OFF 1 0 CONF COND INCR EVM Measure Count CONF COND EVMM int CONF COND EVMM Location Update Delay CONF COND LOC int CONF COND LOC Test Loop Mode CONF COND TESTL GSM A C CONF COND TESTL GSM CONF COND TESTL GPRS ACK A B CONF COND TESTL GPRS CONF COND TESTL EGPRS ACK A B SRB CONF COND TESTL EGPRS Connection Wait Time CONF COND CON int CONF COND CON Signaling Pattern CONF COND SI...

Page 272: ...y Item Command Attenuation Control CONF LOSS ON OFF 1 0 CONF LOSS CONF LOSS RFIN real 1 real 2 real 3 real 4 CONF LOSS RFIN CONF LOSS RFOU real 1 real 2 real 3 real 4 CONF LOSS RFOU Table 6 9 CONDition Limit Command Summary Item Command Power Control Level CONF COND LIM TXP PLEV int CONF COND LIM TXP PLEV Peak TX Power Limit CONF COND LIM TXP int PLEV real LO real HI CONF COND LIM TXP Burst Timing...

Page 273: ...R II real HI CONF COND LIM BER II CONF COND LIM FBER real HI CONF COND LIM FBER CONF COND LIM BERG real HI CONF COND LIM BERG CONF COND LIM SRB real HI CONF COND LIM SRB EVM Limit CONF COND LIM EVM RMS real HI CONF COND LIM EVM RMS CONF COND LIM EVM PEAK real HI CONF COND LIM EVM PEAK CONF COND LIM EVM N real HI CONF COND LIM EVM N Origin Offset Suppression Limit CONF COND LIM ORG real HI CONF CON...

Page 274: ...s Table 6 10 FILE Command Summary Item Command Save File CONF FILE SAVE FILENAME COMMENT Recall File CONF FILE REC filename Delete File CONF FILE DEL filename Device Control CONF FILE DEV HDD USB CONF FILE DEV List Files CONF FILE LIST Replace CONF FILE REP File System CONF FILE SYST GSM WCDMA MULTI CONF FILE SYST Table 6 11 Network Command Summary Item Command Apply Address CONF NET APPLY ADDR IP...

Page 275: ...ET GATE SET1 CONF NET GATE SET2 enum1 IPADDRESS1 enum2 IPADDRES S2 CONF NET GATE SET2 CONF NET GATE SET3 enum1 IPADDRESS1 enum2 IPADDRES S2 CONF NET GATE SET3 CONF NET GATE SET4 enum1 IPADDRESS1 enum2 IPADDRES S2 CONF NET GATE SET4 CONF NET GATE SET5 enum1 IPADDRESS1 enum2 IPADDRES S2 CONF NET GATE ET5 Table 6 11 Network Command Summary Item Command ...

Page 276: ...asuring screens Table 6 12 Automatic Test Stand by Measuring Screen Command Summary Item Command BCCH TEST AUTO BCCH int TEST AUTO BCCH Talk Test TCH TEST AUTO TCH int TEST AUTO TCH TEST AUTO TCH EXP GSM850 GSM900 DCS1800 PSC1900 int TEST AUTO TCH EXP Caller ID TEST AUTO CALL ID string TEST AUTO CALL ID Screen Mode TEST AUTO SCR SIMP DET VAL TEST AUTO SCR Power Ramp Template TEST AUTO RAMP MASK PC...

Page 277: ...0 GSM900 DCS1800 PCS1900 int TEST AUTO VAR TCH CHAN1 EXP TEST AUTO VAR TCH CHAN2 EXP GSM850 GSM900 DCS1800 PCS1900 int TEST AUTO VAR TCH CHAN2 EXP TEST AUTO VAR TCH CHAN3 EXP GSM850 GSM900 DCS1800 PCS1900 int TEST AUTO VAR TCH CHAN3 TEST AUTO VAR TCH CHAN4 EXP GSM850 GSM900 DCS1800 PCS1900 int TEST AUTO VAR TCH CHAN4 EXP TEST AUTO VAR TCH CHAN5 EXP GSM850 GSM900 DCS1800 PCS1900 int TEST AUTO VAR T...

Page 278: ...and Summary Item Command Table 6 13 Automatic Test RESults Command Summary Item Command All Tests Results summary TEST AUTO RES ALL TEST AUTO RES ALL EXP Peak TX Power Measurement TEST AUTO RES TPOW1 TEST AUTO RES TPOW2 TEST AUTO RES TPOW3 TEST AUTO RES TPOW4 TEST AUTO RES TPOW5 TEST AUTO RES TPOW6 Burst Timing Measurement TEST AUTO RES BTIM1 TEST AUTO RES BTIM2 TEST AUTO RES BTIM3 TEST AUTO RES B...

Page 279: ...F 1 0 TEST AUTO RES RAMP3 ZOOM TEST AUTO RES RAMP4 ZOOM ON OFF 1 0 TEST AUTO RES RAMP4 ZOOM TEST AUTO RES RAMP5 ZOOM ON OFF 1 0 TEST AUTO RES RAMP5 ZOOM TEST AUTO RES RAMP6 ZOOM ON OFF 1 0 TEST AUTO RES RAMP6 ZOOM Power Ramp Marker Measurement TEST AUTO RES RAMP1 MARK TEST AUTO RES RAMP2 MARK TEST AUTO RES RAMP3 MARK TEST AUTO RES RAMP4 MARK TEST AUTO RES RAMP5 MARK TEST AUTO RES RAMP6 MARK Table ...

Page 280: ...K POIN real TEST AUTO RES RAMP6 MARK POIN Power Ramp Flatness TEST AUTO RES RAMP1 FLAT TEST AUTO RES RAMP2 FLAT TEST AUTO RES RAMP3 FLAT TEST AUTO RES RAMP4 FLAT TEST AUTO RES RAMP5 FLAT TEST AUTO RES RAMP6 FLAT Power Ramp Trace Start TEST AUTO RES RAMP1 TRAC STAR real TEST AUTO RES RAMP1 TRAC STAR TEST AUTO RES RAMP2 TRAC STAR real TEST AUTO RES RAMP2 TRAC STAR TEST AUTO RES RAMP3 TRAC STAR real ...

Page 281: ...O RES RAMP1 MASK LOW POIN TEST AUTO RES RAMP2 MASK LOW POIN TEST AUTO RES RAMP3 MASK LOW POIN TEST AUTO RES RAMP4 MASK LOW POIN TEST AUTO RES RAMP5 MASK LOW POIN TEST AUTO RES RAMP6 MASK LOW POIN Power Ramp Mask Upper Points TEST AUTO RES RAMP1 MASK UPP POIN TEST AUTO RES RAMP2 MASK UPP POIN TEST AUTO RES RAMP3 MASK UPP POIN TEST AUTO RES RAMP4 MASK UPP POIN TEST AUTO RES RAMP5 MASK UPP POIN TEST ...

Page 282: ...ARK POIN real TEST AUTO RES PHAS2 MARK POIN TEST AUTO RES PHAS3 MARK POIN UP DOWN TEST AUTO RES PHAS3 MARK POIN real TEST AUTO RES PHAS3 MARK POIN TEST AUTO RES PHAS4 MARK POIN UP DOWN TEST AUTO RES PHAS4 MARK POIN real TEST AUTO RES PHAS4 MARK POIN TEST AUTO RES PHAS5 MARK POIN UP DOWN TEST AUTO RES PHAS5 MARK POIN real TEST AUTO RES PHAS5 MARK POIN TEST AUTO RES PHAS6 MARK POIN UP DOWN TEST AUTO...

Page 283: ...t TEST AUTO RES SENS1 TEST AUTO RES SENS2 TEST AUTO RES SENS3 TEST AUTO RES SENS4 TEST AUTO RES SENS5 TEST AUTO RES SENS6 RX Level Measurement TEST AUTO RES LEV1 TEST AUTO RES LEV2 TEST AUTO RES LEV3 TEST AUTO RES LEV4 TEST AUTO RES LEV5 TEST AUTO RES LEV6 RX Quality Measurement TEST AUTO RES QUAL1 TEST AUTO RES QUAL2 TEST AUTO RES QUAL3 TEST AUTO RES QUAL4 TEST AUTO RES QUAL5 TEST AUTO RES QUAL6 ...

Page 284: ...EST MAN BCCH CHAN int TEST MAN BCCH CHAN Traffic Channel TEST MAN TCH CHAN int TEST MAN TCH CHAN TEST MAN TCH CHAN EXP GSM850 GSM900 DCS1800 PCS1900 int TEST MAN TCH CHAN EXP BCCH Frequency TEST MAN BCCH FREQ real TEST MAN BCCH FREQ Traffic Channel Frequency TEST MAN TCH FREQ real TEST MAN TCH FREQ TEST MAN TCH FREQ EXP GSM850 GSM900 DCS1800 PCS1900 real TEST MAN TCH FREQ EXP BS Level TEST MAN AMP...

Page 285: ...FF 2 200 TEST MAN AVER RF output TEST MAN RFOU ON OFF 1 0 TEST MAN RFOU Connection Mode TEST MAN CMOD TALK TEST TEST MAN CMOD Caller ID TEST MAN CALL ID string TEST MAN CALL ID Caller ID send TEST MAN CALL ID SEND ON OFF 1 0 TEST MAN CALL ID SEND Call Drop Timer TEST MAN CDT bool TEST MAN CDT Power Ramp Template TEST MAN TXP MASK PCS NARR REL TEST MAN TXP MASK PCS Table 6 14 Manual Test Stand by S...

Page 286: ... A C TEST MAN TESTL GSM TEST MAN TESTL GPRS ACK A B TEST MAN TESTL GPRS TEST MAN TESTL EGPRS ACK A B SRB TEST MAN TESTL EGPRS Coding Scheme TEST MAN CSCH int TEST MAN CSCH Modulation and Coding Scheme TEST MAN CSCH E int TEST MAN CSCH E Table 6 15 Manual Test Measuring Screen Command Summary Item Command Table 6 16 MSINformation Command Summary Item Command IMSI Information TEST MAN RES MSIN IMSI ...

Page 287: ... Burst Timing Measurement TEST MAN RES BTIM EVM Measurement TEST MAN RES EVM Power Ramp Marker Position Control TEST MAN TXAM RES MARK POIN UP DOWN TEST MAN TXAM RES MARK POIN real TEST MAN TXAM RES MARK POIN Actual Timing Advance TEST MAN RES ACTA Power Ramp Graph Zoom TEST MAN RES RAMP ZOOM ON OFF 1 0 TEST MAN RES RAMP ZOOM Power Ramp Marker Measurement TEST MAN RES RAMP MARK Power Ramp Measurem...

Page 288: ...P MASK UPP Origin Offset Spr Measurement TEST MAN RES OOS EVM Marker TEST MAN RES EVM MARK EVM Marker Point TEST MAN RES EVM MARK POIN UP DOWN TEST MAN RES EVM MARK POIN real TEST MAN RES EVM MARK POIN Table 6 17 Manual Test TPOWer TXAMplitude Command Summary Item Command Table 6 18 Manual Test PHASe TXFRequency Command Summary Item Command Phase Error Measurement TEST MAN RES PHAS Frequency Error...

Page 289: ...M TEST MAN SENS FRAM BERF int TEST MAN SENS FRAM BERF TEST MAN SENS FRAM BERG int TEST MAN SENS FRAM BERG TEST MAN SENS FRAM BLER int TEST MAN SENS FRAM BLER TEST MAN SENS FRAM SRB int TEST MAN SENS FRAM SRB Puncturing Scheme TEST MAN PUNC P1 P2 P3 TEST MAN PUNC Incremental Redundancy TEST MAN INCR ON OFF 1 0 TEST MAN INCR EVM Measurement Count TEST MAN EVMM int TEST MAN EVMM RX Quality Measuremen...

Page 290: ...on Count TEST MAN ORFSC int TEST MAN ORFSC ORFS Modulation Measurement TEST MAN RES ORFS MOD ORFS Switching Measurement TEST MAN RES ORFS SW Ref Power TEST MAN RES ORFS P Table 6 20 Manual Test ORFS Command Summary Item Command Table 6 21 Manual Test SMONitor Command Summary Item Command Resolution Bandwidth TEST MAN SMON RBW 10K 30K TEST MAN SMON RBW Spectrum Measurement TEST MAN RES SMON Spectru...

Page 291: ...ing commands are used to set the controls and parameters associated with the SMS screen Table 6 22 SMS Command Summary Item Command SMS Data TEST MAN SMSC ASC string TEST MAN SMSC ASC TEST MAN SMSC BIN int 1 int 2 int 3 string 4 TEST MAN SMSC BIN TEST MAN SMSC RX SMS Execute TEST MAN SMSC TEST MAN SMSM ...

Page 292: ...AN RFOR RFCH TXAN RFCH CHAN int TXAN RFCH CHAN Frequency TXAN RFCH FREQ real TXAN RFCH FREQ Power Control Level TXAN PLEV int TXAN PLEV Amplitude TXAN AMPL real TXAN AMPL MS Signal TXAN SIGN BURST CW TXAN SIGN Midamble TXAN MID TSC0 TSC1 TSC2 TCS3 TSC4 TSC5 TSC6 TSC7 NONE TXAN MID Peak TX Power Burst Timing Power Ramp TXAN TXP STAT ON OFF 1 0 TXAN TXP STAT Phase Frequency Error TXAN PHAS STAT ON O...

Page 293: ... Command Summary Item Command Power Ramp Template TXAN RAMP MASK PCS NARR REL TXAN RAMP MASK PCS Peak TX Power Measurement TXAN RES TXP Power Ramp Test TXAN RES RAMP Power Ramp Graph Zoom TXAN RES RAMP ZOOM ON OFF 1 0 TXAN RES RAMP ZOOM Power Ramp Marker Measurement TXAN RES RAMP MARK Power Ramp Marker Position Control TXAN RES RAMP MARK POIN UP DOWN TXAN RES RAMP MARK POIN real TXAN RES RAMP MARK...

Page 294: ...6 38 N9360A Multi UE Tester GSM Programming Manual 6 Programming Command Summary Power Ramp Mask Upper TXAN RES RAMP MASK UPP Table 6 24 TX Analyzer TPOWer TXAMplitude Command Summary Item Command ...

Page 295: ...y Command Summary Item Command Phase Error Measurement TXAN RES PHAS Frequency Error Measurement TXAN RES FREQ Frequency Error Measurement Expand TXAN RES FREQ EXP Phase Error Marker Measurement TXAN RES PHAS MARK Phase Error Marker Position Control TXAN RES PHAS MARK POIN UP DOWN TXAN RES PHAS MARK POIN real TXAN RES PHAS MARK POIN EVM Measurement TXAN RES EVM EVM Marker TXAN RES EVM MARK EVM Mar...

Page 296: ...rement TXAN RES ORFS MOD ORFS Switching Measurement TXAN RES ORFS SW Ref Power TXAN RES ORFS P Table 6 26 ORFS Command Summary Item Command Table 6 27 TX Analyzer SMONitor Command Summary Item Command Span TXAN SMON SPAN 400K 100K TXAN SMON SPAN Resolution Bandwidth TXAN SMON RBW 10K 30K TXAN SMON RBW Spectrum Measurement TXAN RES SMON Spectrum Marker Measurement TXAN RES SMON MARK Spectrum Marker...

Page 297: ...RFGenerator Subsystem Command Summary Item Command Radio System RFG RFOR GSM850 GSM900 DCS1800 PCS1900 RFG RFOR Channel RFG CHAN int RFG CHAN Frequency RFG FREQ real RFG FREQ Amplitude RFG AMPL int RFG AMPL Modulation RFG MOD OFF BCCH PN9 PN15 ALL0 ALL1 AM PSK9 PSK15 RFG MOD Frequency Offset RFG OFFS real RFG OFFS RF Signal Output RFG RFOU ON OFF 1 0 RFG RFOU Change System RFG SYST GSM WCDMA CDMA2...

Page 298: ... the system status of the Tester Table 6 29 HCOPy Subsystem Command Summary Item Command Dump Screen Image HCOP SDUM Table 6 30 SYSTem Subsystem Command Summary Item Command System Error SYST ERR Lock System Panel SYST KLOC ON OFF 1 0 SYST KLOC Softkey Memory Softkey Memory Channel SYST MEM CHAN int 1 int 2 int 3 int 4 SYST MEM CHAN Softkey Memory BS Level SYST MEM AMPL real 1 real 2 real 3 real 4...

Page 299: ...gramming Manual 6 43 Trigger Function The following commands are used to control the trigger function of the Tester Table 6 31 TRIGger Subsystem Command Summary Item Command Trigger Immediately TRIG IMM Trigger Mode TRIG MODE SING CONT TRIG MODE Abort TRIG ABOR ...

Page 300: ...6 44 N9360A Multi UE Tester GSM Programming Manual 6 Programming Command Summary THIS PAGE IS INTENTIONALLY LEFT BLANK ...

Page 301: ... GSM function 7 10 Manual Test GPRS Function 7 13 TX Analyzer Function 7 16 This chapter contains an example program contained to be used for testing a GSM850 GSM900 DCS1800 or PCS1900 mobile phone with the Tester Following program use Microsoft Windows and Microsoft Visual Basic Refer to the instruction manual of Visual Basic for further details about Visual Basic ...

Page 302: ...ton on the PC window is pressed Operate the mobile phone following the instructions on the window The performance of each test is described in the test event The followings section describes the program structure 1 Components of Screen Refer to Components of Window 7 3 2 Functions status display sent and received data Refer to Functions 7 4 3 Test Events Refer to Test Event 7 5 ...

Page 303: ...ts of the window are as follows 1 Interface fieldSelects an interface from Ethernet GP IB or RS 232C Controls the Tester by the selected interface The configuration of the interface is shown in Table 7 1 2 Test buttonsStarts each test by pressing a button 3 Status fieldDisplays the status and results of the test This program runs with the configuration shown in Table 7 1 1 3 2 ...

Page 304: ...eld display is described in Table 7 2 Refer to source code file sample bas in the CD R for detail operation Table 7 1 Interface Configuration Tester PC Ethernet IP Address 192 168 0 1 192 168 0 2 to 255 Subnet Mask 255 255 255 0 255 255 255 0 Port 10123 fix 10123 GP IB GP IB Address 2 1 EOI Off Off RS 232C Port COM1 Baud Rate 9600 bps 9600 bps Parity None None Data Length 8 bit 8 bit Stop Bit 1 bi...

Page 305: ...se Ethernet port and RS 232C port The functions provided by the GP IB interface card manufacture are used to initialize open and close GP IB port Outlines of the program are described below 1 Initialize the interface specified on the Interface field 2 Execute the Test Function according to the pressed test button Refer to Automatic Test Function to TX Analyzer Function 3 Close the interface specif...

Page 306: ...erator for test are shown on the status field 1 Public Sub Automatic_Sample 2 Dim value 3 4 ClrStatus 5 6 Tester Status 7 value Split ENTER IDN 8 AddStatus value 0 9 AddStatus value 1 10 AddStatus value 2 11 AddStatus value 3 12 13 Configuration 14 OUTPUT RST 15 OUTPUT CONF LOSS ON 16 OUTPUT CONF LOSS RFIN 0 5 0 5 0 5 0 5 17 OUTPUT CONF LOSS RFOU 1 0 1 0 1 0 1 0 18 19 Measure Setup 20 OUTPUT DISP ...

Page 307: ... WAIT STB 0 42 43 RF Test 44 Dim channel As Integer 45 For channel 1 To 3 46 value Split ENTER TEST AUTO VAR TCH CHAN CStr channel 47 AddStatus Channel CStr channel value 0 48 value Split ENTER TEST AUTO RES TPOW CStr channel 49 AddStatus Peak TX Power High value 2 dBm IIf value 1 And 1 FAIL PASS 50 AddStatus Peak TX Power Mid value 3 dBm IIf value 1 And 2 FAIL PASS 51 AddStatus Peak TX Power Low ...

Page 308: ...s the variable to store test results 4 Erases the status field 7 Queries the manufacturer model number serial number and revision number of the firmware 8 11 Displays the manufacturer model number serial number and revision number of the firmware on the Status Field 14 Resets the Tester to the default setting for programming 15 Activates the Loss connection function 16 Sets the Loss RF IN value 17...

Page 309: ...TX Power High on the status field 50 Displays the measurement value and Pass or Fail result of Peak TX Power Mid on the status field 51 Displays the measurement value and Pass or Fail result of Peak TX Power Low on the status field 52 Queries the measurement result of Burst Timing 53 Displays the measurement value and Pass or Fail result of Burst Timing on the status field 54 Queries the measureme...

Page 310: ... shown on the status field 1 Public Sub Manual_Sample1 2 Dim value 3 4 ClrStatus 5 6 Tester Status 7 value Split ENTER IDN 8 AddStatus value 0 9 AddStatus value 1 10 AddStatus value 2 11 AddStatus value 3 12 13 Configuration 14 OUTPUT RST 15 OUTPUT CONF LOSS ON 16 OUTPUT CONF LOSS RFIN 0 5 0 5 0 5 0 5 17 OUTPUT CONF LOSS RFOU 1 0 1 0 1 0 1 0 18 19 Measure Setup 20 OUTPUT TEST MAN RFOR DCS1800 21 W...

Page 311: ...DISP MAN PHAS 38 OUTPUT TRIG IMM 39 WAIT STB 0 40 value Split ENTER TEST MAN RES PHAS 41 AddStatus Phase Err rms value 2 deg IIf value 1 And 1 FAIL PASS 42 AddStatus Phase Err peak value 3 deg IIf value 1 And 2 FAIL PASS 43 value Split ENTER TEST MAN RES FREQ 44 AddStatus Frequency Error value 2 Hz IIf value 1 And 1 FAIL PASS 45 46 BS Release 47 OUTPUT TEST MAN BSR 48 49 AddStatus Complete 50 End ...

Page 312: ...aling state changes to talk RF Test connection 30 Displays the Peak TX Power Burst Timing Power Ramp screen on the Tester 31 Starts the Peak TX Power measurement 32 Waits until the measurement is completed 33 Queries the measurement result of Peak TX Power 34 Displays the measurement value and Pass or Fail result of Peak TX Power on the status field 37 Displays the Phase Error Frequency Error scre...

Page 313: ...field Operations by an operator are shown on the status field 1 Public Sub Manual_Sample2 2 Dim value 3 4 ClrStatus 5 6 Tester Status 7 value Split ENTER IDN 8 AddStatus value 0 9 AddStatus value 1 10 AddStatus value 2 11 AddStatus value 3 12 13 Configuration 14 OUTPUT RST 15 OUTPUT CONF LOSS ON 16 OUTPUT CONF LOSS RFIN 0 5 0 5 0 5 0 5 17 OUTPUT CONF LOSS RFOU 1 0 1 0 1 0 1 0 18 OUTPUT CONF COND M...

Page 314: ...SS 34 35 Phase Error Freq Error 36 OUTPUT DISP MAN PHAS 37 OUTPUT TRIG IMM 38 WAIT STB 0 39 value Split ENTER TEST MAN RES PHAS 40 AddStatus Phase Err rms value 2 deg IIf value 1 And 1 FAIL PASS 41 AddStatus Phase Err peak value 3 deg IIf value 1 And 2 FAIL PASS 42 value Split ENTER TEST MAN RES FREQ 43 AddStatus Frequency Error value 2 Hz IIf value 1 And 1 FAIL PASS 44 45 BS Release 46 OUTPUT TES...

Page 315: ...completed 26 Displays Attached in the status field 29 Displays the Peak TX Power Burst Timing Power Ramp screen 30 Starts the Peak TX Power measurement 31 Waits until the measurement is completed 32 Queries the measurement result of Peak TX Power 33 Displays the measurement value and Pass or Fail result of Peak TX Power on the status field 36 Displays the Phase Error Frequency Error screen on the ...

Page 316: ...measurement results are shown on the status field 1 Public Sub TXAN_Sample 2 Dim value 3 4 ClrStatus 5 6 Tester Status 7 value Split ENTER IDN 8 AddStatus value 0 9 AddStatus value 1 10 AddStatus value 2 11 AddStatus value 3 12 13 OUTPUT RST 14 15 Signal Generator 16 OUTPUT RFG MOD OFF 17 OUTPUT RFG RFOU ON 18 Sleep 5000 19 20 Peak TX Power 21 OUTPUT DISP TXAN TPOW 22 OUTPUT TRIG IMM 23 WAIT STB 0...

Page 317: ...Queries the manufacturer model number serial number and revision number of the firmware 8 11 Displays the manufacturer model number serial number and revision number of the firmware on the status field 13 Resets the Tester to the default setting for programming 16 Sets the Modulation OFF in the Signal Generator 17 Sets the RF OUTPUT ON in the Signal Generator 18 Waits until the Signal Generator se...

Page 318: ...ass or Fail result of Phase Error RMS on the status field 33 Displays the measurement value and Pass or Fail result of Phase Error Peak on the status field 34 Queries the measurement result of Frequency Error 35 Displays the measurement value and Pass or Fail result of Frequency Error on the status field 38 Displays the TX Analyzer Stand by Screen on the Tester 39 Displays Complete message on the ...

Page 319: ...ndix A Syntax Diagrams Graphical Conversions A 2 Syntax Diagrams A 3 In this Appendix the syntax diagram for each subsystem commands is shown These diagrams use a graphical format to represent the hierarchical structure of the system ...

Page 320: ...Consult with the other section in this guide or the User s Guide for detailed information Represents a command A query command trails a question mark Indicates that a colon must be used between two commands Indicates that a space must be used as a part of the command line Represents one or multiple parameters for integer real string or bool Indicates the series of command parts are omitted in the ...

Page 321: ...M Programming Manual A 3 Syntax Diagrams Figure A 1 IEEE Common Commands Figure A 2 Top Menu Commands IDN RST OPC OPC CLS ESE ESE STB OPT sp int ESR TST ERRor sp bool SYSTem KLOCK KLOCK DISPlay INIT DISPlay CONFigure APPLication APPLication GSM WCDMA CDMA ...

Page 322: ... A Syntax Diagrams Figure A 3 Top Menu Commands Continued 2 CONFigure PRINter PRINter BEEPer BEEPer ROSCillator sp enum bool sp AUTOBoot AUTOBoot sp enum init2 DATE DATE TIME sp intYYYY intMM intDD sp intHH intMM TIME sp enum ROSCillator REVision RF FCOPy SDUMp ...

Page 323: ... TYPE RESult HISTory HISTory HDD SERver LIST FIRMware sp TRIGger LIST FUNCtiontester G00 W00 SYStem REVision FUNCtiontester G00 W00 FLASh TRIGger LIST MENU MENU MC1X 1XEVDO REVision MC1X 1XEVDO sp enum sp int POSition REQuest NUMber NUMber CLEar FILE IPaddress RELOad sp string sp int enum sp enum TYPE POSition NUMber IPaddress ...

Page 324: ...PPOWer TPOWer PHASe SENSitivity STBY TPOWer PHASe SENSitivity SMONitor SMS STBY TPOWer PHASe SMONitor STBY MANual TXANalyzer RFGenerator CONFigure CONFigure CONDition SEQuence FILE DISPlay sp enum sp enum sp enum sp enum sp enum ORFS ORFS LOSS APPLication TESTer MODe NETwork Limit BA MREPorting TABLe LIST sp enum sp int sp int ...

Page 325: ...Appendix A Syntax Diagrams A N9360A Multi UE Tester GSM Programming Manual A 7 Figure A 6 INITialsoftkey Subsystem CURrentsystem enum INITialsoftkey sp MODe MODe sp enum ...

Page 326: ...ter BEEPer BEEPer PKEY PKEY sp enum bool sp enum sp a b f ROSCillator LOSS DATE DATE TIME TIME sp intY intM intD sp intH intM CONDition MODE MODE RFORmat RFORmat NETWork MCC MCC MNC MNC NCC NCC LAC LAC BSPA BSPA PCLass PCLass sp enum sp enum int sp int int int int sp sp sp sp sp int CURrentsystem CURrentsystem sp enum 3GPPsystem init sp 3GPPsystem ...

Page 327: ... sp sp int a b f HIGH HIGH MEDium MEDium LOW LOW DATA DATA AVERage AVERage AMPLitude MAN MAN AMPLitude SENSitivit y sp int b a f int int int LDElay LDElay CSCHeme CSCHeme enum int sp sp EGPRS enum sp EGPRS INCRementalredundancy bool sp enum sp PUNCturing PUNCturing INCRementalredundancy LEVel LEVel FRAMe FRAMe BERFast BERFast BERGprs BERGprs BLER BLER sp sp sp int SRB SRB sp ...

Page 328: ...HASe FREQuency sp int int sp sp real LO sp sp sp real HI c a EVM Meascount int sp EVM Meascount SIGNalingpattern SIGNalingpattern int sp LOCupdatedelay LOCupdatedelay int sp Enum sp TestLoopmode CONnectionwait int sp CONnectionwait GPRS GPRS GSM GSM sp Enum sp Enum EGPRS EGPRS sp Enum real HI real LO real HI real HI real HI real LO IB IB BER sp real HI II II real HI sp FREQuency EXPand FREQuency s...

Page 329: ...nt HI int LO real HI a EVM RMS RMS real sp PEAK PEAK real sp NIntyfive Nintyfive real sp ORIGinoffsetspr ORIGinoffsetspr sp real ORFS MODuration MODuration int sp Switching Switching int sp BLER BLER sp real HI MODuration enum sp real MODuration EXPand EXPand Switching enum sp real EXPand Switching EXPand FBER FBER BER Gprs BER Gprs sp real HI sp real HI SRB SRB sp real HI TYPE real sp TYPE ...

Page 330: ...Nnel6 sp sp sp CHANnel6 sp sp sp int int int int int int CHANnel1 CHANnel1 CHANnel2 CHANnel2 CHANnel3 CHANnel3 sp sp sp int int int EXP EXP EXP EXP EXP EXP enum enum enum f FREQuency real sp FREQuency real sp enum FREQuency EXP EXP d SEQuence NO NO BCCH CHANnel CHANnel FREQuency FREQuency TCH CHANnel CHANnel FREQuency sp enum int real int sp sp sp RFORmat RFORmat sp enum RELeasdelay RELeasdelay sp...

Page 331: ...eal4 real1 real4 real1 real4 real1 real4 RFIN QUALity QUALity LEVel LEVel int int sp sp int int int sp FREQuency SENSitivity FREQuency BER BER FER FER sp sp int sp b a f sp int sp int PHASe RMS RMS PEAK PEAK d sp int RAMP RAMP c sp int sp int sp int sp int BTIMing BTIMing TPOWer MIDium MIDium HIGH HIGH LOW LOW CHANnel4 CHANnel4 CHANnel5 CHANnel5 CHANnel6 CHANnel6 sp sp sp int int int EXP EXP EXP E...

Page 332: ...TALK TALK bool sp enum sp bool sp enum REL1 TYPE TYPE RFTEST RFTEST sp bool sp sp enum CALL 2 TYPE TYPE CALL2 CALL2 bool CHANnel6 sp real1 d CHANnel6 real4 f c a CHANnel1 CHANnel1 CHANnel2 CHANnel2 CHANnel3 CHANnel3 CHANnel4 CHANnel4 CHANnel5 CHANnel5 real1 sp sp sp sp sp real4 real1 real4 real1 real4 real1 real4 real1 real4 RFOUT c CHANnel6 CHANnel6 sp real1 real4 CHANnel5 CHANnel5 sp real1 real4...

Page 333: ...gure Loss Subsystem f a LIST REPlace SYSTem SYSTem sp enum FILE SAVE RECall DELete DEVice DEVice sp enum FILENAME strin g COMMEN T sp sp sp FILENAME string FILENAME sp enum REL2 TYPE TYPE sp RFOUtput RFOUtput enum sp 3GPPsystem 3GPPsystem int c string string CONFigure RFIN LOSS LOSS LOSS RFIN RFOUt RFOUt bool sp real1 sp real4 real1 sp real4 ...

Page 334: ...ATEway GATEway DEFault sp enum GATEway GATEway SET1 GATEway sp SET1 enum1 string1 enum2 string2 GATEway sp SET1 enum GATEway SET2 GATEway sp SET2 enum1 string1 enum2 string2 GATEway sp SET2 enum GATEway SET3 GATEway sp SET3 enum1 string1 enum2 string2 GATEway sp SET3 enum GATEway SET4 GATEway sp SET4 enum1 string1 enum2 string2 GATEway sp SET4 enum GATEway SET5 GATEway sp SET5 enum1 string1 enum2 ...

Page 335: ...nel2 CHANnel2 CHANnel3 CHANnel3 CHANnel4 CHANnel4 CHANnel5 CHANnel5 CHANnel6 CHANnel6 ID CALLer ID sp enum sp enum a TCH TCH sp int EXP EXP enum TCH CHANnel1 VARiable CHANnel1 CHANnel2 CHANnel2 CHANnel3 CHANnel3 CHANnel4 CHANnel4 CHANnel5 CHANnel5 CHANnel6 CHANnel6 sp sp sp sp sp sp int int int int int int sp sp sp sp sp sp int int int int int int EXP EXP EXP EXP EXP EXP EXP EXP EXP EXP EXP EXP en...

Page 336: ... A Syntax Diagrams Figure A 18 TESTs Subsystem for Automatic Test Continued 2 TALK MEASure SIGNaling STATe sp RESults ALL enum TPOWer1 TPOWer2 TPOWer3 TPOWer4 TPOWer5 TPOWer6 BTIMing1 BTIMing2 BTIMing3 BTIMing4 BTIMing5 BTIMing6 a f STATe EXPand ALL EXPand a b f ...

Page 337: ...bool ZOOM MARKer MARKer POINt POINt sp enum real RAMP1 RAMP2 RAMP2 ZOOM RAMP2 sp bool ZOOM MARKer MARKer POINt POINt sp enum real RAMP2 RAMP1 RAMP1 FLATNESS TRACe TRACe STARt NUMber RAMP1 MASK LOWer l UPPer RAMP1 MASK LOWer l UPPer RAMP1 POINts POINts RAMP2 RAMP2 FLATNESS TRACe TRACe STARt NUMber RAMP2 MASK LOWer l UPPer RAMP2 MASK LOWer l UPPer RAMP2 POINts POINts b f ...

Page 338: ...OOM MARKer MARKer POINt POINt sp enum real RAMP4 RAMP4 ZOOM sp bool ZOOM MARKer MARKer POINt POINt sp enum real FLATNESS TRACe TRACe STARt NUMber MASK LOWer l UPPer MASK LOWer l UPPer POINts POINts FLATNESS TRACe TRACe STARt NUMber MASK LOWer l UPPer MASK LOWer l UPPer POINts POINts b f RAMP3 RAMP3 RAMP3 RAMP3 RAMP3 RAMP3 RAMP3 RAMP4 RAMP4 RAMP4 RAMP4 RAMP4 RAMP4 RAMP4 ...

Page 339: ...OOM MARKer MARKer POINt POINt sp enum real RAMP6 RAMP6 ZOOM sp bool ZOOM MARKer MARKer POINt POINt sp enum real FLATNESS TRACe TRACe STARt NUMber MASK LOWer l UPPer MASK LOWer l UPPer POINts POINts FLATNESS TRACe TRACe STARt NUMber MASK LOWer l UPPer MASK LOWer l UPPer POINts POINts b f RAMP5 RAMP5 RAMP5 RAMP5 RAMP5 RAMP5 RAMP5 RAMP6 RAMP6 RAMP6 RAMP6 RAMP6 RAMP6 RAMP6 ...

Page 340: ...RKer MARKer POINt PHASe1 PHASe1 b PHASe2 PHASe2 MARKer MARKer POINt PHASe2 POINt sp enum real PHASe3 PHASe3 MARKer MARKer POINt PHASe3 POINt sp enum real PHASe4 PHASe4 MARKer MARKer POINt PHASe4 POINt sp enum real POINt sp enum real PHASe5 PHASe5 MARKer MARKer POINt PHASe5 PHASe6 PHASe6 MARKer MARKer POINt PHASe6 POINt sp enum real POINt sp enum real ...

Page 341: ...ency3 FREQuency4 FREQuency5 FREQuency6 SENSitivity1 SENSitivity2 SENSitivity3 SENSitivity4 SENSitivity5 SENSitivity6 b QUALity1 QUALity2 QUALity3 QUALity4 QUALity5 QUALity6 LEVel1 LEVel2 LEVel3 LEVel4 LEVel5 LEVel6 MSINformation IMSI IMEI DIAL PCLass GVERsion FREQuency1 FREQuency2 FREQuency3 FREQuency4 FREQuency5 FREQuency6 EXPand EXPand EXPand EXPand EXPand EXPand ...

Page 342: ...p long STATe sp sp sp sp sp sp PHASe STATe sp SENSitivity STATe int long int long int bool STATe sp bool bool a CHANnel FREQuency FREQuency TCH CHANnel CHANnel FREQuency RFEQuency PLEVel PLEVel AMPLitude AMPLitude TADVance TADVance TXPower STATe STATe enum sp int sp sp CHANnel CHANnel sp long FREQuency RFEQuency EXP EXP EXP EXP int enum enum f CDTimer CDTimer bool sp ...

Page 343: ...BIN RX sp sp sp sp sp enum enum enum string int1 string a AVERage AVERage SCONfigure SCONfigure MSLOt MSLOt SMSCbmt int3 sp enum CMODe CMODe CALLer ID ID sp string SEND SEND sp bool f a f HANDover SYSTem WCDMA sp bool RFOUtput RFOUtput sp enum SYSTem LOCupdate BSCall BSRelease MSAnswer SCLear SIGNaling STATe SMSCb SMSMt STATe STATe EXTension EXPand ...

Page 344: ...ms Figure A 26 TESTs Subsystem for Manual Test Continued 3 a sp enum GRPS GRPS GSM GSM TESTLoopmode sp enum EGPRS EGPRS sp enum CSCHeme CSCHeme sp int EGPRS EGPRS sp int Signaling BTIMing RESults TXPower EVM OOS EVM MARKer MARKer POINt POINt sp enum real Signaling EXPand f f b a ...

Page 345: ...nual A 27 Figure A 27 TESTs Subsystem for Manual Test Continued 4 b f RAMP RAMP ZOOM sp bool ZOOM MARKer MARKer POINt POINt sp enum real FLATNESS TRACe TRACe STARt NUMber MASK LOWer l UPPer MASK LOWer l UPPer POINts POINts b f ACTAdvance RAMP RAMP RAMP RAMP RAMP RAMP RAMP ...

Page 346: ...undancy sp bool EVMMeascount sp int INCRementalredundancy EVMMeascount ORFSCount sp int ORFSCount SMONitor RBWidth RBWidth TXAMplitude MARKer sp enum POINt POINt sp enum real RESults MOD SW ORFS STATe STATe STATe STATe sp bool sp bool sp int sp int sp int BERFast BERFast sp int SRB SRB sp int PLEVel PLEVel LEVel LEVel FRSMe FRAMe SENSitivity b MARKer MARKer sp PHASe FREQuency PHASe POINt POINt enu...

Page 347: ...p sp sp sp sp sp sp int long enum enum bool bool enum RFORmat RFCH enum sp sp long PLEVel PLEVel AMPLitude AMPLitude SIGNal SIGNal MIDamble MIDamble TXPower STATe STATe PHASe STATe STATe AVERage AVERage a MODulation enum sp MODulation OFFSet real sp OFFSet RFOUtput enum sp RFOUtput DEMODulation enum sp DEMODulation EVMMeasurecount int sp EVMMeasurecount f SYSTem sp enum SYSTem ...

Page 348: ... Diagrams Figure A 30 TX Analyzer Subsystem Continued 2 TXPower RESults RAMP RAMP ZOOM sp bool ZOOM MARKer MARKer POINt POINt sp enum real FLATNESS TRACe TRACe STARt NUMber MASK LOWer l UPPer MASK LOWer l UPPer POINts POINts RAMP RAMP RAMP RAMP RAMP RAMP RAMP b f a b f a ...

Page 349: ... Figure A 31 TX Analyzer Subsystem Continued 3 MARKer sp enum real MARKer POINt POINt a a c b MARKer MARKer sp PHASe FREQuency PHASe POINt POINt enum real SMONitor SMONitor MARKer MARKer POINt POINt sp enum real MARKer MARKer sp EVM POINt POINt enum real EVM OOS ORFS MOD SW Power ...

Page 350: ...SM Programming Manual A Appendix A Syntax Diagrams Figure A 32 TX Analyzer Subsystem Continued 4 a a SMONitor SPAN SPAN RBWidth RBWidth sp enum sp enum MOD ORFS STATe STATe SW STATe STATe sp bool sp bool ORFSCount sp int ORFSCount ...

Page 351: ...ure A 33 RFGenerator Subsystem Figure A 34 HCOPy Subsystem RFORmat RFGenerator RFORmat CHANnel CHANnel FREQuency FREQuency AMPLitude AMPLitude MODulation MODulation OFFSet OFFSet RFOUtput RFOUtput sp enum sp int sp long sp int sp enum sp long sp bool SYSTem SYSTem sp enum SDUMp HCOPy ...

Page 352: ...ng Manual A Appendix A Syntax Diagrams Figure A 35 System Subsystem Figure A 36 TRIGer Subsystem ERRor sp bool SYSTem KLOCK KLOCK MEMory CHANnel CHANnel AMPLitude AMPLitude sp int1 int4 sp int1 int4 RBT IMMediate sp enum TRIGer MODE MODE ABORt ...

Reviews: