Programming Command Reference
5
N9360A Multi UE Tester GSM Programming Manual
5-5
Top Menu Commands
The following Top Menu commands are available only on the
[Top Menu] screen or the [Configuration] screen. These
commands are unavailable in any screen other than the [Top
Menu] and the [Configuration] screen. The other commands
except for the Top Menu Commands and the IEEE Common
Commands are unavailable.
System Commands
System Error
SYSTem:ERRor?
This query command returns a set of values,
<int 1>
and
<string 2>
, for error numbers and error messages. Refer to
.
Lock System Panel
SYSTem:KLOCk ON|OFF|1|0
SYSTem:KLOCk?
This command sets all the panel keys setting to
ON
(1) or
OFF
(0). If this is set to
ON
or
1
, all the panel keys are locked. If this
is set to
OFF
or
0
, all the panel keys are unlocked. At preset, this
is set to
0
. This query command returns the panel keys setting
with integer value of
1
or
0
.
Option Code
OPTion:SET <string>
This command installs an option code to the Tester with 16
ASCII characters.