5-94
N9360A Multi UE Tester GSM Programming Manual
5
Programming Command Reference
This command sets the test result of the Talk test step to pass or
fail. The parameter is
PASS
or
FAIL
.
Signaling State
TESTs:AUTO:MEASure:SIGNaling:STATe?
This query command returns the test step currently executed in
a test cycle. The return value contains the currently executed
status of 9 bits as follows.
bit 0 (1): Location Update
bit 1 (2): 1st Call
bit 2 (4): Talk
bit 3 (8): RF Test
bit 4 (16): 1st Release
bit 5 (32): 2nd Call
bit 6 (64): 2nd Release
bit 7 (128): Measurement end with test result
bit 8 (256): Measurement end without test result (Aborted or
Time out error occurred)
The executed step is set to
1
, and the others are set to
0
.
The value in the parentheses is decimal value for each bit. Refer
to
Setting and Querying the Registers
TESTs:AUTO:MEASure:SIGNaling:STATe:EXPand?
This query command returns the test contents currently being
executed and system type with integer value contained
<int
1>
and
< int 2>
. Each value is separated by a comma.
<int 1>
contains test contents currently being executed. The
return value of
12
bits are as follows:
bit 0 (1): Location Update
bit 1 (2): 1st Call
bit 2 (4): Talk
bit 3 (8): 1st Release
bit 4 (16): 2nd Call