5-150
N9360A Multi UE Tester GSM Programming Manual
5
Programming Command Reference
•
<real4>
is the measurement results. If measurement result
is out of range or measurement result is not measured, the
value
-99. 99
is returned.
Power Ramp Mask Lower Points
TESTs:MANual:RESults:RAMP:MASK:LOWer:POINTs?
This query command returns the number of lower limit sections
in the Power Ramp template.
•
<int>
is
13
. It is a fixed value.
Power Ramp Mask Upper Points
TESTs:MANual:RESults:RAMP:MASK:UPPer:POINTs?
This query command returns the number of upper limit sections
in the Power Ramp template.
•
<int>
is
13
. It is a fixed value.
Power Ramp Mask Lower
TESTs:MANual:RESults:RAMP:MASK:LOWer?
This query command returns the point of section end (Bits) and
the limit value (dB) of lower limit sections in the Power Ramp
template.
•
<real1>
,
<real3>
,
<real5>
,
<real7>
,
<real9>
,
<real11>
,
<real13>
,
<real15>
,
<real17>
,
<real19>
,
<real21>
,
<real23>
,
<real25>
show the point of section
end (Bits). Refer the
•
<real2>
,
<real4>
,
<real6>
,
<real8>
,
<real10>
,
<real12>
,
<real14>
,
<real16>
,
<real18>
,
<real20>
,
<real22>
,
<real24>
,
<real26>
show the limit value
(dB).
N O T E
When the GPIB - USB converter is used, the maximum number of data is
until 300.