Programming Command Reference
5
N9360A Multi UE Tester GSM Programming Manual
5-95
bit 5 (32): NA
bit 6 (64): 2nd Release
bit 7 (128): NA
bit 8 (256): RF Test
bit 9 (512): NA
bit 10 (1024): Measurement end with test result
bit 11 (2048): Measurement end without test result (Aborted
or Time out error occurred)
The executed step is set to
1
, and the others are set to
0
.
The value in the parentheses is decimal value for each bit. Refer
to
Setting and Querying the Registers
Power Ramp Template
TESTs:AUTO:RAMP:MASK:PCS NARRow|RELaxed
TESTs:AUTO:RAMP:MASK:PCS?
This command sets template type of Power Ramp measuremnt
for PCS1900. The parameter is
NARRow
or
RELaxed
. At preset,
this is set to
NARRow
. If
RELaxed
is set, the template is selected
same one for DCS1800. This setting is initialized to
NARRow
at
power on.
IMSI control
TESTs:AUTO:IMSI <string>
TESTs:AUTO:IMSI?
This command sets IMSI in Automatic Test [Stand-by] screen.
The maximum digit of
<string>
is
15
and the range of a digit
is from
0
to
9
. The value is set a value without double quotation.
Preset value is
001012345678901
.