Programming Command Reference
5
N9360A Multi UE Tester GSM Programming Manual
5-125
At preset, this is set to
2
.
This query command returns the set slot order measured for the
GPRS/EGPRS mode with integer. The variety of return value is
same as that of the command parameter.
Peak TX Power/Burst Timing/Power Ramp Test
TESTs:MANual:TXPower:STATe ON|OFF|1|0
TESTs:MANual:TXPower:STATe?
This command sets whether to execute the Peak TX Power Burst
Timing and Power Ramp test. The parameter is
ON
(1) or
OFF
(0). At preset, this is set to
1
.
This query command returns the set of the Peak TX Power,
Burst Timing and Power Ramp test with integer value of
1
or
0
.
The meaning of the return value is same as that of the command
parameter.
Phase Error/Frequency Error/EVM/Origin Offset Spr. Test
TESTs:MANual:PHASe:STATe ON|OFF|1|0
TESTs:MANual:PHASe:STATe?
This command sets whether to execute the Phase Error,
Frequency Error, and EVM, Origin Offset Spr. test. The
parameter is
ON
(1) or
OFF
(0). At preset, this is set to
1
.
This query command returns the set of the Phase Error and
Frequency Error test with integer value of
1
or
0
. The meaning
of the return value is same as that of the command parameter.
N O T E
If the mode is set to GPRS/EGPRS, this command is valid.