5-166
N9360A Multi UE Tester GSM Programming Manual
5
Programming Command Reference
TXANalyzer Subsystem
Command Reference for Stand-by/Measuring Screens
These commands are used to set the controls and parameters
associated with the TX Analyzer mode.
Radio System
TXANalyzer:RFORmat GSM850|GSM900|DCS1800|PCS1900
TXANalyzer:RFORmat?
This command selects a Radio System to be tested. The
parameter is specified from
GSM850
,
GSM900
,
DCS1800
and
PCS1900
. At preset, this is set to
GSM900
.
This query command returns the selected Radio System with
strings.
RFCH
TXANalyzer:RFCH:CHANnel <int>
TXANalyzer:RFCH:CHANnel?
This command sets the channel number to be tested for each
radio system set by the
command described
above. The allowable range and preset values are as follows:
The setting of this command and the setting of the
command described on
change synchronously.
This query command returns the set channel number to be
tested with integer. The range of the value is same as that of the
command parameter.
Table 5-42 RFCH Channel Number Allowable Range and Preset Value
RFORmat
Allowable Range
Preset Value
GSM850
128 to 251
188
GSM900
955 to 1023, 0 to 124
20
DCS1800
512 to 885
698
PCS1900
512 to 810
698