84
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\meas_pfer_desc.fm
Phase and Frequency Error Measurement Description
Burst Synchronization
The PFER measurement provides the user a choice for the time reference (burst synchronization). see
Synchronization of Measurements” on page 115
Related Topics
*******************************************************
“Programming a Phase and Frequency Error Measurement” on page 85
“Test Adherence to Standards” on page 110
*******************************************************
Table 4.
Burst Synchronization
Description
Midamble
References measurement timing to the midamble
transmitted within a timeslot.
RF Amplitude
The amplitude rise and fall of a transmitted burst
determines the measurement time reference.
None
No edge of the burst will be detected, the
measurement will be made using the first 87 or 147
bits of data found centered around the middle of the
expected burst position. For may be used when
measuring non-bursted signals
Summary of Contents for 8960 Series 10
Page 26: ...26 Contents ...