386
S:\Hp8960\E1960A GSM Mobile Test Application\A.04 Release\Reference_Manual\Chapters\hpib_setup_berror.fm
SETup:BERRor
SETup:BERRor:CLSDelay[:STIMe]
SETup:BERRor:CLSDelay:TIME
Function
Selects/queries the closed loop signalling delay time in seconds for Bit Error measurements and
sets the delay state to ON. The units (S|MS) are optional, if no units are specified than units
default to S.
The delay time defines how long the test set should wait before starting a BERR measurement.
The downlink signalling operation must be completed and the test set must send a close loop
command to the MS before the measurement can begin. The delay time allows time for the loop to
close.
When a close loop message is set to the MS the closed loop signalling delay time will hold off the
BERR measurement from starting for the specified time period.
Setting
Range: 0 to 5 seconds
Resolution: 100 ms
Query
Range: 0 to 5 seconds
Resolution: 100 ms
*RST
500 ms
Programming Example
OUTPUT 714;”SETUP:BERROR:CLSDELAY:STIME 400 MS” ! Set state to on
! and delay time
Function
Selects/queries the closed loop signalling delay time in seconds for Bit Error measurements. The
units (S|MS) are optional, if no units are specified than units default to S.
The delay time defines how long the test set should wait before starting a BERR measurement.
The downlink signalling operation must be completed and the test set must send a close loop
command to the MS before the measurement can begin. The delay time allows time for the loop to
close.
When a close loop message is set to the MS the closed loop signalling delay time will hold off the
BERR measurement from starting for the specified time period.
Setting
Range: 0 to 5 seconds
Resolution: 100 ms
Query
Range: 0 to 5 seconds
Resolution: 100 ms
*RST
500 ms
Programming Example
OUTPUT 714;”SETUP:BERROR:CLSDELAY:TIME 600MS” ! Set delay time
Summary of Contents for 8960 Series 10