Select the qualifier time set softkey (
<
or
>
), then rotate the Entry
knob to set the pulse width qualifier time.
The qualifiers can be set as follows:
•
2 ns to 10 s for > or < qualifier (5 ns to 10 s for 350 MHz
bandwidth models).
•
10 ns to 10 s for >< qualifier, with minimum difference of 5 ns
between upper and lower settings.
Pulse width
trigger < qualifier
time set softkey
•
When the less than (
<
) qualifier is selected, the Entry knob sets the
oscilloscope to trigger on a pulse width less than the time value
displayed on the softkey.
•
When the time range (
><
) qualifier is selected, the Entry knob sets the
upper time range value.
Pulse width
trigger > qualifier
time set softkey
•
When the greater than (
>
) qualifier is selected, the Entry knob sets the
oscilloscope to trigger on a pulse width greater than the time value
displayed on the softkey.
•
When the time range (
><
) qualifier is selected, the Entry knob sets the
lower time range value.
Video Trigger
Video triggering can be used to capture the complicated waveforms of
most standard analog video signals. The trigger circuitry detects the
vertical and horizontal interval of the waveform and produces triggers
based on the video trigger settings you have selected.
The oscilloscope's MegaZoom IV technology gives you bright, easily viewed
displays of any part of the video waveform. Analysis of video waveforms is
simplified by the oscilloscope's ability to trigger on any selected line of the
video signal.
10 ns
15 ns
Trigger
12 ns
Summary of Contents for 2000 X
Page 1: ...s1 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Page 18: ...18 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide ...
Page 42: ...42 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 1 Getting Started ...
Page 62: ...62 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 3 Vertical Controls ...
Page 76: ...76 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 4 Math Waveforms ...
Page 100: ...100 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 6 Digital Channels ...
Page 106: ...106 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 7 Display Settings ...
Page 134: ...134 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 9 Triggers ...
Page 142: ...142 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 10 Trigger Mode Coupling ...
Page 168: ...168 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 12 Cursors ...
Page 204: ...204 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 15 Digital Voltmeter ...
Page 216: ...216 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 16 Waveform Generator ...
Page 236: ...236 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 18 Print Screens ...
Page 272: ...272 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 20 Web Interface ...
Page 290: ...290 Agilent InfiniiVision 2000 X Series Oscilloscopes User s Guide 21 Reference ...