Parameters
U600 User’s Guide
C-80
Aerotech, Inc.
Version 1.4
All of these parameters may be changed on the fly.
Changing the axes, or jog mode on the jog page will overwrite these task parameters.
Likewise, changing these parameters will change their complementary values on the
jog page.
C.4.53.
JogPair1Axis1MinusIn
This task parameter defines the virtual input number that when True (active high) will
cause Axis 1 of Jog Pair 1 (as defined by JogPair1Axis1 ) to jog minus in the current jog
mode (as defined by the JogPair1Mode task parameter).
C.4.54.
JogPair1Axis1PlusIn
This task parameter defines the virtual input number that when True (active high) will
cause Axis 1 of Jog Pair 1 (as defined by JogPair1Axis1) to jog plus in the current jog
mode (as defined by the JogPair1Mode task parameter).
C.4.55.
JogPair1Axis2MinusIn
This task parameter defines the virtual input number that when True (active high) will
cause Axis 2 of Jog Pair 1 (as defined by JogPair1Axis2) to jog minus in the current jog
mode (as defined by the JogPair1Mode task parameter).
C.4.56.
JogPair1Axis2PlusIn
This task parameter defines the virtual input number that when True (active high) will
cause Axis 2 of Jog Pair 1 (as defined by JogPair1Axis2) to jog plus in the current jog
mode (as defined by the JogPair1Mode task parameter).
C.4.57.
JogPair1EnableIn
This task parameter defines the virtual input number that when True (active high) will
cause Jog Pair 1 (as defined by JogPair1Axis1) to move in the current jog mode (as
defined by the JogPair1Mode task parameter). SecNum_JogPair1AxisExample
C.4.58.
JogPair1Axis1
This task parameter defines the first axis that will be commanded to move by the virtual
input specified by the JogPair1EnableIn task parameter. The value is specified as a
bitmask. Bit 0 represents the first axis (default name X), bit 2 the second axis (default
name Y), etc. See Section C.4.59.1. for more information on setting this parameter.
C.4.59.
JogPair1Axis2
This task parameter defines the second axis that will be commanded to move by the
virtual input specified by the JogPair1EnableIn task parameter. The value is specified as a
bitmask. Bit 0 represents the first axis (default name X), bit 2 the second axis (default
name Y), etc. See Section C.4.59.1. for more information on setting this parameter.
Summary of Contents for UNIDEX 600 Series
Page 19: ...Table of Contents U600 User s Guide xviii Aerotech Inc Version 1 4...
Page 27: ...Preface U600 User s Guide xxvi Aerotech Inc Version 1 4...
Page 163: ...AerPlot U600 User s Guide 6 6 Aerotech Inc Version 1 4...
Page 169: ...AerReg U600 User s Guide 8 4 Aerotech Inc Version 1 4...
Page 177: ...AerPlotIO U600 User s Guide 10 4 Aerotech Inc Version 1 4...
Page 179: ...Filter U600 User s Guide 11 2 Aerotech Inc Version 1 4...
Page 219: ...PrmSetup U600 User s Guide 13 2 Aerotech Inc Version 1 4...
Page 223: ...Glossary of Terms U600 User s Guide A 4 Aerotech Inc Version 1 4...
Page 353: ......