73
RESET (CLEAR) FEATURE
This dive computer is configured with a RESET feature that allows
data to be cleared, including Nitrogen and Oxygen calculations,
FO2 set point, and Log Mode entries.
RESET PROCEDURE:
While in Surface Mode (new activation period or after a 10
minute post dive surface interval), press the Advance (Front)
button 1 time to access Plan Mode.
While 30 feet (or 9 meters) is displayed in the Plan Mode, press
and hold Both buttons until SET 2 appears, then release the but-
tons.
Press and release the Advance (Front) button to display the
Clear screen (Fig. 74). The first 2 digits of the KEY CODE
flash.
If necessary to change the number, press and release the Select
(Side) button until the digits to change to
01
.
Press and release the Advance (Front) button again to display
the second 2 digits of the KEY CODE, flashing.
If necessary to change the number, press and release the Select
(Side) button until the digits change to
01
.
Press and release the Advance (Front) button to complete the
RESET operation and turn the unit OFF.
WARNING: Reset
after a dive and
subsequent use
for a repetitive
dive conducted
by the same diver
could result in se-
rious injury to or
death.
Fig. 74 - Clear (Reset)