36
TO SET - MAX PO2 ALARM
(while in the Surface Mode)
Factory set for 1.60 (ATA), the Maximum PO2 Alarm can be set
to values between 1.20 and 1.60 (ATA) in increments of .10
(ATA).
Press Both buttons simultaneously, release when
SET: 2
ap-
pears.
Press and release the Advance (Front) button, the Units screen
appears with the set point
flashing.
Press the Advance (Front) button
10 more times.
The graphics
PO2
and
MAX
, and Alarm icon appear with the
PO2 value
flashing (Fig. 35).
Press and release the Select (Side) button to advance the Alarm
value in increments of .10 (ATA), or press and hold the button
to scroll through the Set Points.
Press the Advance (Front) button to accept the setting and ad-
vance to Set FO2 50% Default, or press and hold Both buttons
for 2 seconds to revert to Surface Mode.
Fig. 35 - Set Max PO2 Alarm