TO SET - MAX NITROGEN BAR GRAPH ALARM
(while in the Surface Mode)
Factory set for DECO (all 8 segments), the Maximum Nitrogen Bar
Graph (NiBG) Alarm can be set to values between DECO (8 seg-
ments) and 1 segment.
Press Both buttons simultaneously, release when
SET: 2
ap-
pears.
Press and release the Advance (Front) button, the Units screen
appears with the set point
flashing.
Press the Advance (Front) button
8 more times.
The graphic
ndc
and Alarm icon appear with the full
Nitrogen
Bar Graph
flashing (Fig. 33).
Press and release the Select (Side) button to decrease the num-
ber of segments one at a time, or press and hold the button to
scroll through the Set Points.
Press the Advance (Front) button to accept the setting and ad-
vance to Set Dive Time Remaining Alarm, or press and hold
Both buttons for 2 seconds to revert to Surface Mode.
Fig. 33 - Set Max Nitrogen Bar
Graph Alarm