41
TO SET - WET ACTIVATION
(while in the Surface Mode)
Factory set ON, this feature can also be set OFF (disabled). When
set ON, the ATMOS 2 will automatically Activate and enter Dive
Mode upon immersion in water and descent to 5 feet (1.5 meters).
WARNING: If the Wet Activation feature is set OFF,
the ATMOS 2 must be manually (push button) acti-
vated prior to commencing a dive.
Press Both buttons simultaneously, release when
SET: 2
ap-
pears.
Press and release the Advance (Front) button, the Units screen
appears with the set point
flashing.
Press the Advance (Front) button
15 more times
(14 more
times if a dive was made with Digital Gauge Mode set ON).
The graphics
ACT
and
H2O
appear with
ON
(or OFF) flash-
ing (Fig. 40).
Press and release the Select (Side) button to toggle between
ON and OFF.
Press the Advance (Front) button to accept the setting and re-
vert to Surface Mode.
Fig. 40 - Set Water Activation