55
The added Penalty (decompression) Time will have to be 'worked
off' first, before obtaining off-gassing credit. Once the Penalty
Time is worked-off, and off-gassing credit begins, required decom-
pression Stop Depths and Time will decrease toward zero, then the
Nitrogen Bar Graph will recede into the yellow Caution Zone and
the ATMOS 2 will revert to the No Decompression Dive Mode.
NOTE: Upon entry into Delayed Violation Modes,
the Audible Alarm will sound, even if it is user Set
OFF. It cannot be turned off (acknowledged) by
pressing the Advance (Front) button.
Delayed Violation Mode #1
(Fig. 53)
If you remain above the Required Ceiling Stop Depth for 'more
than 5 minutes',
the Nitrogen Bar Graph and Total Ascent Time
display will flash until you descend below the Required Stop
Depth. This is a continuation of a Conditional Violation.
Delayed Violation Mode #2
(Fig. 54)
The ATMOS 2 cannot calculate decompression times for Stop
Depths much greater than 60 feet (18 meters) and offers no indica-
tion of how much dive time would result in the need for a greater
Stop Depth.
Fig. 53 - Delayed Violation #1
Flashing
Flashing
Fig. 54 - Delayed Violation #2
Flashing