Technical Specifications
X - 214
SCOPIX
Technical Specifications
Mains « Harmonics » Analysis Mode
« Recorder » Mode
Display of "Harmonics"
Selection of the page in the "Display" menu
Even harmonics
2 to 60 + Fundamental on 2 pages
Odd harmonics
3 to 31 + Fundamental on 2 pages
All harmonics
2 to 61 + Fundamental on 4 pages
Fundamental Frequency of the
signal analyzed
40 to 450 Hz
Measurement accuracy
Level of Fundamental
± 2 % ± +10 of Reading
Level of Harmonics
± 3 % ± +10 of Reading
Harmonic Distortion
± 4 %
Oscilloscope not equipped
with the
EXTENDED ACQUISITION
MEMORY option
Oscilloscope equipped with the
EXTENDED ACQUISITION
MEMORY option
Recording period
from 2 seconds to 1 month
Sampling rate
from 800 µs to 17 mins 51 secs
from 40 µs to 53.5 secs
Fault capture
10 faults in memory up to
500 faults in files
100 faults in memory up to
200 faults in files
Triggering
Triggering search by sample analysis;
Trigger if Detection of:
•
Signal
above
threshold
•
Signal
below
threshold
•
Signal below or above threshold
•
Signal outside of two defined limits
Trigger event period
Trigger if the condition is verified during a parameterizable period:
Min. value of the period
Recording period / 625
Recording period / 12500
Max. value of the period
Recording period / 4
Recording period / 4
Display
Search for minimum and maximum
Fault search
Vertical, horizontal accuracy
Identical specifications to those in "Oscilloscope" mode
www.
ShopAEMC
.com
Shop for AEMC products online at:
1.877.766.5412
Summary of Contents for OX 7102 III
Page 117: ...Multimeter Mode SCOPIX V 117 www ShopAEMC com Shop for AEMC products online at 1 877 766 5412...
Page 155: ...Recorder Mode SCOPIX VII 155 www ShopAEMC com Shop for AEMC products online at 1 877 766 5412...
Page 199: ...Applications SCOPIX IX 199 www ShopAEMC com Shop for AEMC products online at 1 877 766 5412...