42/23-81 EN Rev. 4
System Manual SCK Gas Sampling System
81
Danger
Where / in what situa-
tion does the danger
arise?
Preventive action
Danger due to harm-
ful gases, jet flames
Due to gases escaping
from the duct opening of
the rotary kiln
Ensure adequate ventila-
tion of the work place.
Only enter the danger area
around the retractor when
the shutter is closed.
Lock the shutter before
commencing work, if this is
indicated.
If work is unavoidable in the
area of the duct opening,
wear respiratory protection.
Risk of scalding due
to hot cooling water
When working on the
cooling water system,
particularly:
ventilation
openings
screw
connections
Do not perform work on the
cooling water circuit until
the gas sampling system
has cooled down.
Danger due to harm-
ful anti-freeze
In the cooling water of
the cooling system
Avoid contact with the
cooling water and the anti-
freeze.
Wash any cooling water
and anti-freeze off the skin
immediately with water and
soap.
If cooling water or anti-
freeze gets in the eyes de-
spite protective glasses,
rinse them thoroughly un-
der running water, holding
the eyelids open.
Observe instructions in the
anti-freeze manufacturer's
safety data sheet.
Danger due to harm-
ful lubricating oil
In the pneumatic box, on
the pneumatic motor
filter muffler, inside the
pneumatic motor.
Avoid contact with lubricat-
ing oil.
Wash any lubricating oil off
the skin immediately with
water and soap.
If any lubricating oil gets in
the eyes despite protective
glasses, rinse them thor-
oughly under running water,
holding the eyelids open.
Observe instructions in the
lubricating oil manufactur-
er's safety data sheet.
Danger due to harm-
ful dust
While cleaning the gas
sampling system
Wear a dust mask.
Wash any dust off the skin
immediately with water and
soap.
Summary of Contents for SCK
Page 2: ......
Page 16: ......
Page 36: ......
Page 54: ......
Page 110: ......
Page 222: ......
Page 232: ......
Page 235: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 235 ...
Page 236: ...236 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Electrical connection plan ...
Page 237: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 237 ...
Page 238: ...238 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Transformer connection plan ...
Page 242: ......
Page 243: ......