42/23-81 EN Rev. 4
System Manual SCK Gas Sampling System
129
How to check the current monitoring relays for correct settings:
Step
Procedure
1
Open the control cabinet.
2
Check current monitoring relays
-K35
and
-K36
for correct settings.
Settings for
-K35
and
-K36
:
Hysteresis
5%
Threshold
4,5 A
Tripping delay
0,1 s
Start-up delay
5 s
There is a DIP switch under the white flap. Check the following
settings here:
1 Undercurrent monitoring ON
2 NC contact operation
ON
3 Storage off
OFF
4 (Default)
OFF
3
Close the control cabinet.
Checking current
monitoring
relays