30
System Manual SCK Gas Sampling System
42/23-81 EN Rev. 4
Gas sampling probe 60S
The gas sampling probe is used to sample the sample gas from the process.
The following illustration shows the gas sampling probe 60S:
The main components of the gas sampling probe 60S are:
No. Component
Function
1
Sample gas intake holes
Sucks in the sample gas in the kiln.
2
Gas tube
Transports the sample gas through
the probe to the gas outlet.
3
Connection for air cannon
Compressed-air blast from air can-
non breaks up material deposits
between the probe and the wall tube.
4
Wall tube
Pipe stub on rotary kiln.
5
Cooling water connections Cooling water supply for probe cool-
ing.
6
Mounting flange
For fastening the gas sampling probe
to the retractor.
7
Filter unit FE2
Initial filtering of the sample gas for
dust removal.
8
Ceramic filter
9
Compressed air connec-
tions
Allows periodical cleaning of the filter
with compressed air.
10
Protective case
Filter unit casing.
11
Gas outlet
Passes the sample gas to the down-
line sample gas analysis system.
12
Heating sleeve
Heats the filter unit to prevent con-
densation build-up.
13
Pipe sealing device
Spring-mounted sealing of the tube
Meaning
Layout
Function of
components
Summary of Contents for SCK
Page 2: ......
Page 16: ......
Page 36: ......
Page 54: ......
Page 110: ......
Page 222: ......
Page 232: ......
Page 235: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 235 ...
Page 236: ...236 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Electrical connection plan ...
Page 237: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 237 ...
Page 238: ...238 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Transformer connection plan ...
Page 242: ......
Page 243: ......