42/23-81 EN Rev. 4
System Manual SCK Gas Sampling System
119
Proceed as follows to switch on the gas sampling system:
Step Procedure
1
Shut off the compressed-air using the gate valve
(1)
in the pneu-
matic box of the probe retractor so as to prevent any undesirable
probe movements.
2
Completely vent the compressed-air tank (if present).
3
Open the control cabinet.
4
Turn on the main switch of the gas sampling system.
5
Switch on uninterruptible power supply (if present).
6
Switch on residual current circuit-breaker in the control cabinet (if
present).
7
Flip the fuse switches one by one in the control cabinet.
8
Wait for controller to boot.
9
Start frequency converter.
10
Adjust local time (password for "Advance Service" required).
Path:
Setup
►
System
►
Time setting
11
Open the compressed-air gate valve
(1)
again.
WARNING!
Depending on the current position, the probe begins to
move towards to the rear end position (probe completely retracted).
Do not stand in the area of travel of the probe or probe car-
riage.
12
Switch on the cooling-water pump on the touchscreen.
Path:
Operation
►
Cooling Water Pump
►
ON
13
Wait for the heated modules to heat up until the following error
messages disappear:
"Probe heating temperature MIN"
"Cable Drag Chain Sample Gas Line Temp. Error"
Path:
Diagnosis
►
Message
14
Turn service switch to
ON
position.
Note:
This step resets various safety functions.
Switching on the gas
sampling system.
Summary of Contents for SCK
Page 2: ......
Page 16: ......
Page 36: ......
Page 54: ......
Page 110: ......
Page 222: ......
Page 232: ......
Page 235: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 235 ...
Page 236: ...236 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Electrical connection plan ...
Page 237: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 237 ...
Page 238: ...238 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Transformer connection plan ...
Page 242: ......
Page 243: ......