34
System Manual SCK Gas Sampling System
42/23-81 EN Rev. 4
Transformer
The gas sampling system can be fitted with a three-phase dry transformer (see
System identification
on page 12). The three-phase dry transformer is located in a
sheet metal casing with door and base, wiring is by means of threaded connec-
tions. The casing is dip-impregnated to protect against moisture.
Power
6900.00 VA UL
Primary voltage
3 x 208 V (delta)
Secondary voltage
3 x 400 V (star)
Degree of protection
IP 54
Test voltage
4.0 kV
Insulation category
T 50/A
Winding
separate
Protection class
I
Frequency
60 Hz
Switching
YNd5
PRI-/SEC connection
Terminals with screw connection
Transformer option
Characteristics/
Design features