42/23-81 EN Rev. 4
System Manual SCK Gas Sampling System
215
Observation Possible
causes
Measures
Compressed-air
hose bursts or
compressed-air
pipe cracks
Pressure
controller
defective
Incorrect pressure set
on pressure controller
Close gate valve in pneu-
matic box, then wait for all
compressed-air to blow
out completely before ap-
proaching
Shut down gas sampling
system and secure against
start-up until the cause
has been fixed
Cooling-water pipe
bursts or cracks
Mechanical damage to
the pipe from outside
Wait until all cooling water
has run out before ap-
proaching
Shut down gas sampling
system and secure against
start-up until the cause
has been fixed
Do not begin repair work
until it has cooled down
Probe or heat
exchanger cracks
Mechanical
damage
and thermal stress
Wait until all cooling water
has run out before ap-
proaching
Shut down gas sampling
system and secure against
start-up until the cause
has been fixed
Do not begin repair work
until it has cooled down
Probe movement
blocked
Mechanical
damage
Incrustation
Press
EMERGENCY
STOP switch before work-
ing on the probe
Remove
blockage
Summary of Contents for SCK
Page 2: ......
Page 16: ......
Page 36: ......
Page 54: ......
Page 110: ......
Page 222: ......
Page 232: ......
Page 235: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 235 ...
Page 236: ...236 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Electrical connection plan ...
Page 237: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 237 ...
Page 238: ...238 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Transformer connection plan ...
Page 242: ......
Page 243: ......