194
System Manual SCK Gas Sampling System
42/23-81 EN Rev. 4
How to check oil level on the compressed-air oiler
-J74
:
Step Procedure
1
Check oil level in the tank inspection windows on the compressed-
air oiler
-J74
.
Guidelines:
Minimum:
Bottom edge of the bottom inspection window
Maximum:
Top quarter in the top inspection window
2
Shut off the compressed-air using the gate valve
-J54
(1)
in the
pneumatic box of the probe retractor.
3
Completely drain the compressed-air tank (if present).
4
Unscrew the tank on the compressed-air oiler
-J74
by turning it
counter-clockwise.
5
Fill oil up to the top quarter of the top inspection window and screw
tank back on.
6
Remove any oil residue with a cloth.
7
Open the compressed-air gate valve
-J54
(1)
again.
8
Turn service switch back to
OFF
position and insert probe again
using the controller.
WARNING!
Probe moves into the kiln.
Do not stand in the area of
travel of the probe or probe carriage until the probe is com-
pletely inserted into the kiln and the warning lamps go out.
Instructions:
checking oil level
Summary of Contents for SCK
Page 2: ......
Page 16: ......
Page 36: ......
Page 54: ......
Page 110: ......
Page 222: ......
Page 232: ......
Page 235: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 235 ...
Page 236: ...236 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Electrical connection plan ...
Page 237: ...42 23 81 EN Rev 4 System Manual SCK Gas Sampling System 237 ...
Page 238: ...238 System Manual SCK Gas Sampling System 42 23 81 EN Rev 4 Transformer connection plan ...
Page 242: ......
Page 243: ......