Technical data
84
Connectors:
• 34-pin parallel bus connector
• 2 RJ-45 connectors (X1 and X2)
Current consumption:
• 290 mA average (5 V), supplied by the drive control board.
General:
• Estimated min. lifetime: 100 000 h
• All materials are UL/CSA approved.
• Complies with EMC Standards EN 50081-2 and EN 50082-2.
EtherCAT® link
Compatible devices:
All EtherCAT® compliant devices
Medium:
100 base TX
• Termination: Internal
• Wiring: CAT 5 UTP, CAT 5 FTP* or CAT 5 STP*
(*Recommended)
• Connector: RJ-45
• Maximum segment length: 100 m
Serial Communication Type:
Full duplex
Transfer Rate:
100 Mbit/s
Protocol:
EtherCAT