CoE object dictionary
61
0×1011
0
Restore default
parameters
U8
RO Largest supported subindex.
Default parameters can be restored
by writing 0x64616F6C ("daol") to
the relevant sub index.
1
Restore all
parameters
U32
RW Restore all parameters.
2
Restore
communication
(objects
0×1000…
0×1A16)
parameters
U32
RW Communication parameters are not
stored on the module.
3
Restore drive
profile (objects
0×603F…
0×60FE,
0×2001…
0×200B)
parameters
U32
RW Restore all DSP 402 parameters.
4
Restore drive
parameters
U32
RW Restore drive default parameters.
0×1018
0
Identity object
U8
RO Number of entries
1
Vendor ID
U32
RO Value: 0×B7 = ABB (Oy)
2
Product code
U32
RO Drive dependent, e.g. 0×201 =
ACS550
3
Revision
U32
RO Module software revision, format
0×XXXX.XXXXh
4
Serial number
U32
RO Serial number of the module.
Index
(hex)
Sub-
index
Name
Type
Attri-
bute
Information
Summary of Contents for RECA-01
Page 1: ...ABB Drives User s Manual EtherCAT Adapter Module RECA 01 ...
Page 4: ......
Page 6: ...Safety instructions 6 ...
Page 24: ...Quick start up guide 24 ...
Page 26: ...Mechanical installation 26 ...
Page 28: ...Electrical installation 28 ...
Page 32: ...Master configuration 32 ...
Page 56: ...Communication 56 ...
Page 72: ...CoE object dictionary 72 ...
Page 80: ...CoE Error codes 80 ...