Mechanical installation
25
Mechanical installation
What this chapter contains
This chapter contains placing and mounting instructions for the
module.
WARNING!
Follow the safety instructions given in this manual and
in the appropriate drive hardware manual
.
Mounting
The RECA-01 module is to be inserted into its specific position in
the drive. The module is held in place with plastic retaining clips
and two screws. The screws also provide the earthing of the
CAT 5 STP cable shield connected to the module, and
interconnect the GND signals of the module and the control board
of the drive.
On installation of the module, the signal and power connection to
the drive is automatically made through a 34-pin connector.
Mounting procedure:
• Insert the module carefully into its position inside the drive until
the retaining clips lock the module into position.
• Fasten the two screws (included) to the stand-offs.
Note:
Correct installation of the screws is essential for fulfilling the
EMC requirements and for proper operation of the module.