2101510 Rev. AG
Page 3–51
3.26.2 Instructions
The technician responsible for installing the gas supply must
follow local and national codes.
1)
Using the manufacturer's instructions supplied with the regulator, make
external gas connections.
2)
Apply Teflon
®
tape to the port one nipple on the filter/drain assembly.
3)
Insert the port one nipple on the filter/drain assembly into the output port on the
regulator and tighten the nut (see
The technician responsible for installing the power supply
must follow local and national codes.
4)
Using the wiring instructions shown in
instructions enclosed with heater, make external connections.
Figure 3-53 ENC82S Filter/Drain Assembly Installation
Customer Gas Inlet
(¼” NPT)
Vent Drain
Catalytic Heater Inlet
Add Filter/Drain Asm here
Drain
(¼” NPT)
Regulator
Bracket/Tie Strap
Stopcock
Filter/Drain Kit
P/N: 2103855
Regulator