Action
A screen is displayed, tap
Rev. Counters
.
en0400000771
4
Tap
Update Revolution Counters...
.
A dialog box is displayed, warning that updating the revolution counters may change
programmed robot positions:
•
Tap
Yes
to update the revolution counters.
•
Tap
No
to cancel updating the revolution counters.
Tapping
Yes
displays the axis selection window.
5
Select the axis to have its revolution counter updated by:
•
Ticking in the box to the left
•
Tapping
Select all
to update all axes.
Then tap
Update
.
6
A dialog box is displayed, warning that the updating operation cannot be undone:
•
Tap
Update
to proceed with updating the revolution counters.
•
Tap
Cancel
to cancel updating the revolution counters.
Tapping
Update
updates the selected revolution counters and removes the tick from
the list of axes.
7
CAUTION
If a revolution counter is incorrectly updated, it will cause incorrect manipulator posi-
tioning, which in turn may cause damage or injury!
Check the synchronization position very carefully after each update. See
the synchronization position on page 422
.
8
402
Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
5 Calibration
5.3 Updating revolution counters
Continued