Note
Action
xx1800000788
Valid for IRB 2600 Type C-20/1.65, IRB
2600 Type C-12/1.65:
Remove the two guide pins from the gear-
box.
14
xx1800000796
Remove the guide from the protection tube.
15
Refitting the arm system to the base
Note
Action
xx1800000797
Valid for IRB 2600 Type C-20/1.65, IRB
2600 Type C-12/1.65:
1
Remove the three gaskets on the
base.
2
Wipe out the oil from the holes in the
base and wipe the sealing surfaces
dry.
3
Fit three new gaskets to the base.
The gaskets are included with the
gearbox spare part.
1
See
Refitting the base on page 296
Refit the complete arm system to the base.
2
See
Refit the axis-1 motor.
3
See
Replacing gearbox axis 1 on page 357
•
Refitting the cable harness in the
base on page 213
•
Refitting the cable harness in the
frame on page 210
•
Refitting the cable harness in the
lower arm and armhouse on
page 219
.
Refit the cable harness in the base, the
frame and the lower arm.
4
Continues on next page
368
Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
4 Repair
4.8.1 Replacing gearbox axis 1
Continued
Summary of Contents for IRB 2600 Series