Note
Action
xx0800000329
Move the upper arm to a position where the
wrist is pointing towards the floor as shown in
the figure.
This way the wrist can be removed without
drainage.
2
DANGER
Turn off all:
•
electric power supply
•
hydraulic pressure supply
•
air pressure supply
to the robot, before entering the robot working
area.
3
WARNING
Handling gearbox oil involves several safety
risks. Before proceeding, please read the safety
information in the section
work with gearbox lubricants (oil or grease) on
page 39
4
CAUTION
The robot wrist unit weighs 15 kg.
All lifting accessories used must be sized ac-
cordingly!
5
See the figure in:
•
Location of wrist unit on
page 262
Remove the
attachment screws
and carefully
remove the wrist unit.
CAUTION
Do not damage gears!
6
WARNING
The wrist unit is filled with oil. Perform removal
with care.
See the figure in
•
Location of wrist unit on
page 262
Pour out the oil from the wrist unit.
7
Continues on next page
264
Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
4 Repair
4.4.3 Replacing wrist unit
Continued
Summary of Contents for IRB 2600 Series