Note
Action
Disconnect connectors on the SMB unit:
•
R1.SMB1-2
•
R1.SMB2-6
•
R2.SMB
14
A
xx0900000035
Disconnect the
screen connections
of:
•
R1.SMB1-2
•
R1.SMB2-6
15
Parts:
•
A: Screen connection (4 pcs)
xx0900000015
Disconnect the
earth cables
.
16
Parts:
•
A: Earth
•
B: Distance screws
Continues on next page
202
Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
4 Repair
4.3.1 Removing the complete cable harness
Continued