Information
Action
A
F
B
xx1100000694
A 100 mm (dial indicator)
B 140 mm
Apply load F=40N downwards at a distance
B from the rotation center of axis 6.
11
The maximum play allowed is:
•
IRB 2600ID - 15/1.85: 0.20 mm
•
IRB 2600ID - 8/2.00: 0.22 mm
Remove the load and measure the play by
reading the dial indicator.
12
Turn axis 6 to +180°.
13
Repeat