5.1.3 Battery capacity
5.1.4
Computer board
Back-up capacity
Battery, type
Battery expected life-time
Serial measurement board
Battery capacity
Expected life-time
Recharging time
Diskette capacity
Winchester capacity (option)
Signal capacity
External I/O connection
Digital
Analogue
Signal connections, on robot arm
Signals
Power
Grounding
Air (connections foot R3/8 "inner,
arm Rl/4* inner)
aprox. 50000 hours
3.6 V lithium
5 years (if environme
temp <35° C)
1000hrs(4Ah)
5 years (<50°C)
18 hours
7 x 32 kword (448 kb
250 x 32 kword
0-96 inputs / 0-96 outputs
0-4 inputs / 0-4 outputs
24
6
1
1
50 V, 250 mA
250 V, 2 A
Max 8 bar,
inner diameter 6mm
Fig 5.1 Signal capacity
5.1.5 Man - machine communication
Programming method
Point to point method by:
• interactive dialogue
• manual running by
joystick.
• off-line programming
via terminal
Description
1KB 2000
28
Summary of Contents for IRB 2000
Page 8: ...Description 1KB 2000 ...
Page 10: ...Description 1KB 2000 ...
Page 12: ...Description 1KB 2000 6 ...
Page 20: ...Description 1KB 2000 14 ...
Page 32: ...Description 1KB 2000 26 ...
Page 40: ...5 3 2 Dimensional drawings Description 34 1KB 2000 ...
Page 41: ..._200 _D D_ Description 35 1KB 2000 ...
Page 44: ...Description 1KB 2000 38 ...
Page 64: ...Description 1KB 2000 58 ...
Page 77: ...Safety 1KB 2000 IBB 3000 12 1KB 3200 1KB 6000 ...
Page 80: ...Installation H B 2000 ...
Page 82: ...Installation 1KB 2000 ...
Page 91: ...Installation 1KB 2000 12 ...
Page 95: ...Installation 1KB 2000 16 ...
Page 110: ...INSTALLATION S3 0 4 ...
Page 112: ...INSTALLATION S3 1 2 ...
Page 160: ...INSTALLATION 3 46 ...
Page 234: ...INSTALLATION 5 70 ...
Page 262: ...INSTALLATION S3 7 6 ...