6.2.1
Technical data
Resolvers of transmitter type, external
Electrical data
Primary
Frequency
Rated voltage
Impedance
Supply capacity
Secondary
Transmission ratio
Impedancex
Fine resolver ratio
Coarse resolver ratio
Sync switches, limit switches
Max. voltage
Load
Motor, Internal axis 7
Technical data
drive units
Rotor
2 kHz
5.6 Vrms
>150 ohm
0.5 A rms (12 resolvers)
Stator
0.5 ±10%
<200 ohm
1:1
136:137
35VDC
min 10 mA
ABB Production
Development have further
information.
Resolver for serial measurement board
Electrical data
Primary Rotor
Frequency 3-4 kHz
Rated voltage 5 Vrms
Impedance >350 ohm
Secondary
Transmission ratio
Impedancex
Phase shift
Stator
0.5 ±10%
<400 ohm
-5° ±3°
INSTALLATION
6:3
Summary of Contents for IRB 2000
Page 8: ...Description 1KB 2000 ...
Page 10: ...Description 1KB 2000 ...
Page 12: ...Description 1KB 2000 6 ...
Page 20: ...Description 1KB 2000 14 ...
Page 32: ...Description 1KB 2000 26 ...
Page 40: ...5 3 2 Dimensional drawings Description 34 1KB 2000 ...
Page 41: ..._200 _D D_ Description 35 1KB 2000 ...
Page 44: ...Description 1KB 2000 38 ...
Page 64: ...Description 1KB 2000 58 ...
Page 77: ...Safety 1KB 2000 IBB 3000 12 1KB 3200 1KB 6000 ...
Page 80: ...Installation H B 2000 ...
Page 82: ...Installation 1KB 2000 ...
Page 91: ...Installation 1KB 2000 12 ...
Page 95: ...Installation 1KB 2000 16 ...
Page 110: ...INSTALLATION S3 0 4 ...
Page 112: ...INSTALLATION S3 1 2 ...
Page 160: ...INSTALLATION 3 46 ...
Page 234: ...INSTALLATION 5 70 ...
Page 262: ...INSTALLATION S3 7 6 ...