3BHS842007 E01 REV C
ACS6080
USER MANUAL
113/238
05 MECHANICAL INSTALLATION
3.
Lift the heat exchanger by crane and move it approximately 20 cm to
the back and place it on pieces of square timber.
4.
Pull out the cables, but leave them connected.
5.
Put two pieces of square timber on the adjacent heat exchanger and
place the removed heat exchanger on the timber.
6.
Join the DC busbars with the supplied installation material.
5.8.2.2
Reinstalling an air-to-air heat exchanger
1.
Move the heat exchanger to its original position.
2.
Pull the cables down towards the terminal box.
3.
Move the heat exchanger to its exact position.
4.
Fix the cables with cable ties at regular distances of
approximately 20 cm.
5.
Tighten all screws of the heat exchanger.
6.
Fix the cables inside the terminal box with cable ties.