08 OPERATION
3BHS842007 E01 REV C
ACS6080
USER MANUAL
168/238
8.5.2.1
Lamp test
The illuminated push buttons on the doors can be tested with the lamp
test function as described in the firmware manual.
8.6
EXU control panel
Figure 8-5 DCS880 control panel
An EXU uses the same type of assistant control panel as the drive for
controlling, reading the status data of and setting the parameters of a
DCS880 or DCT880 unit in the EXU cabinet
Note:
For an overview of the control panel buttons and usage, see “8.5
Assistant control panels” on page 164.
8.6.1
Operational settings
Note:
The control panel is only used if an alarm or a fault condition must
be rectified.
After commissioning of the EXU, the control panel is set to remote, and
local operation is locked in parameter
16.04 LocLock
. This setting
prevents the control panel being switched to local control unintentionally.
Remote operation is indicated with the letters REM in the top left corner
of the display.
The actual values shown on the display can be freely selected. The
following default values are shown on the display when the panel is in
local mode:
Loc/Rem
?
Start
Stop
Options
23:58
Menu
Local
DCS880
1400.0 rpm
Motor speed
Rpm
Motor current
A
Field current
A
1400.0
1028.8
10.9
▲
NOTICE
Risk of component damage!
DO NOT unlock local operation and switch the control panel to remote
while the drive is in operation!
• If you attempt to perform these actions, the drive shuts down